Abstract

We introduce a simplified model of physiological coughing or sneezing, in the form of a thin liquid layer subject to a rapid (30 m/s) air stream. The setup is simulated using the Volume-Of-Fluid method with octree mesh adaptation, the latter allowing grid sizes small enough to capture the Kolmogorov length scale. The results confirm the trend to an intermediate distribution between a Log-Normal and a Pareto distribution P(d)∝d−3.3P(d) \propto d^{-3.3} for the distribution of droplet sizes in agreement with a previous re-analysis of experimental results by one of the authors. The mechanism of atomisation does not differ qualitatively from the multiphase mixing layer experiments and simulations. No mechanism for a bimodal distribution, also sometimes observed, is evidenced in these simulations.

Explore this paper’s authors, topics and related work.

Building this map preview

BZPEER is loading the nearby papers, people, topics and institutions for this page.

Reviews 0

Write a reviewWrite

No reviews yet.

Discussion 0

Add a commentWrite

No comments yet.