Researcher profile

Zhihao Guo

Zhihao Guo contributes to research discovery and scholarly infrastructure.

ResearcherAffiliation not importedOpen to collaborate

Trust snapshot

Quick read

Trust 13 - UnverifiedVerification L1Unclaimed author
2works
0followers
3topics
4close collaborators

Actions

Decide how to stay connected

Follow researcher0

Identity and collaboration

How to connect with this researcher

Claiming links this public author record to a researcher profile and unlocks direct collaboration workflows.

Log in to claim

Direct collaboration

Open a focused conversation when the fit is right

Claim this author entity first to unlock direct invitations.

Research graph

See the researcher in context

Open full explorer

Inspect adjacent work, topics, institutions and collaborators without jumping out to a separate graph page.

Building this graph slice

BZPEER is loading the nearby papers, people, topics and institutions for this page.

Published work

2 published item(s)

preprint2026arXiv

GP-GS: Gaussian Processes Densification for 3D Gaussian Splatting

3D Gaussian Splatting (3DGS) enables photorealistic rendering but suffers from artefacts due to sparse Structure-from-Motion (SfM) initialisation. To address this limitation, we propose GP-GS, a Gaussian Process (GP) based densification framework for 3DGS optimisation. GP-GS formulates point cloud densification as a continuous regression problem, where a GP learns a local mapping from 2D pixel coordinates to 3D position and colour attributes. An adaptive neighbourhood-based sampling strategy generates candidate pixels for inference, while GP-predicted uncertainty is used to filter unreliable predictions, reducing noise and preserving geometric structure. Extensive experiments on synthetic and real-world benchmarks demonstrate that GP-GS consistently improves reconstruction quality and rendering fidelity, achieving up to 1.12 dB PSNR improvement over strong baselines.

preprint2022arXiv

Single-beam double-pass miniaturized atomic magnetometer for bio-magnetic imaging systems

Miniaturized atomic magnetometers, particularly spin-exchange relaxation-free atomic magnetometers, have been emerging in clinical imaging applications such magnetocardiography and magnetoencephalography. Miniaturization, portability, and low cost are primary development targets for bio-magnetic imaging technologies, as well as high sensitivity and spatial and time resolution. In this paper, we propose a low-cost solution for a bio-magnetic imaging system based on atomic magnetometers, in which one laser source is used for a multi-channel atomic magnetometer sensor array. A novel design is demonstrated for a miniaturized spin-exchange relaxation-free atomic magnetometer, consisting of a single-beam double-pass configuration based on an optical fiber circulator. The effects of temperature and laser power on the zero-field magnetic resonance line-width are characterized, and the experimental results show that the present design achieves better performance, than a traditional single-beam single-pass configuration. The noise power spectrum shows that the closed-loop miniaturized atomic magnetometer reaches a sensitivity of approximately 120 fT/Hz$^{1/2}$ at a bandwidth of 10 Hz. This design is especially suitable for atomic magnetometers operating in arrays as a basic building element for low-cost bio-magnetic imaging systems.