Source author record

Z. R. Zhou

Z. R. Zhou appears in the imported research catalog. Authorship, coauthor and topic links are available while profile ownership is still unclaimed.

ResearcherUnclaimed source record

Catalog footprint

What is connected

2works
5topics
4close collaborators

Actions

Connect this record

Log in to claim

Research graph

See the researcher in context

Open full explorer

Inspect adjacent papers, topics, institutions and collaborators without losing the researcher page.

Building this map preview

BZPEER is loading the nearby papers, people, topics and institutions for this page.

Published work

2 published item(s)

preprint2022arXiv

Ultra-wide Bandwidth Observations of 19 pulsars with Parkes telescope

Flux densities are basic observation parameters to describe pulsars. In the most updated pulsar catalog, 24% of the listed radio pulsars have no flux density measurement at any frequency. Here, we report the first flux density measurements, spectral indices, pulse profiles, and correlations of the spectral index with pulsar parameters for 19 pulsars employing the Ultra-Wideband Low (UWL) receiver system installed on the Parkes radio telescope. The results for spectral indices of 17 pulsars are in the range between -0.6 and -3.10. The polarization profiles of thirteen pulsars are shown. There is a moderate correlation between the spectral index and spin frequency. For most pulsars detected, the S/N ratio of pulse profile is not high, so DM, Faraday rotation measure (RM), and polarization can not be determined precisely. Twenty-nine pulsars were not detected in our observations. We discuss the possible explanations for why these pulsars were not detected.

preprint2013arXiv

A new measurement method of electrode gains for orthogonal symmetric type beam position monitor

The new beam position monitor (BPM) system of the injector at the upgrade project of Hefei Light Source (HLS II) has 19 stripline beam position monitors. Most consist of four orthogonal symmetric stripline electrodes. The differences in electronic gain and mismachining tolerance can cause the change of the beam response of the BPM electrodes. This variation will couple the two measured horizontal positions in order to bring the measuring error. To alleviate this effect, a new technique to measure the relative response of the four electrodes has been developed. It is irrelevant to the beam charge and the related coefficient can be theoretical calculated. The effect of electrodes coupling on this technique is analyzed. The calibration data is used to fit the gain for all 19 injector beam position monitors. The results show the standard deviation of the distribution of measured gains is about 5%.