Researcher profile

Y. -Y. Chang

Y. -Y. Chang contributes to research discovery and scholarly infrastructure.

ResearcherAffiliation not importedOpen to collaborate

Trust snapshot

Quick read

Trust 21 - EmergingVerification L1Unclaimed author
9works
0followers
9topics
4close collaborators

Actions

Decide how to stay connected

Follow researcher0

Identity and collaboration

How to connect with this researcher

Claiming links this public author record to a researcher profile and unlocks direct collaboration workflows.

Log in to claim

Direct collaboration

Open a focused conversation when the fit is right

Claim this author entity first to unlock direct invitations.

Research graph

See the researcher in context

Open full explorer

Inspect adjacent work, topics, institutions and collaborators without jumping out to a separate graph page.

Building this graph slice

BZPEER is loading the nearby papers, people, topics and institutions for this page.

Published work

9 published item(s)

preprint2022arXiv

Constraints on Lightly Ionizing Particles from CDMSlite

The Cryogenic Dark Matter Search low ionization threshold experiment (CDMSlite) achieved efficient detection of very small recoil energies in its germanium target, resulting in sensitivity to Lightly Ionizing Particles (LIPs) in a previously unexplored region of charge, mass, and velocity parameter space. We report first direct-detection limits calculated using the optimum interval method on the vertical intensity of cosmogenically-produced LIPs with an electric charge smaller than $e/(3\times10^5$), as well as the strongest limits for charge $\leq e/160$, with a minimum vertical intensity of $1.36\times10^{-7}$\,cm$^{-2}$s$^{-1}$sr$^{-1}$ at charge $e/160$. These results apply over a wide range of LIP masses (5\,MeV/$c^2$ to 100\,TeV/$c^2$) and cover a wide range of $βγ$ values (0.1 -- $10^6$), thus excluding non-relativistic LIPs with $βγ$ as small as 0.1 for the first time.

preprint2022arXiv

Effective Field Theory Analysis of CDMSlite Run 2 Data

CDMSlite Run 2 was a search for weakly interacting massive particles (WIMPs) with a cryogenic 600 g Ge detector operated in a high-voltage mode to optimize sensitivity to WIMPs of relatively low mass from 2 - 20 GeV/$c^2$. In this article, we present an effective field theory (EFT) analysis of the CDMSlite Run 2 data using an extended energy range and a comprehensive treatment of the expected background. A binned likelihood Bayesian analysis was performed on the recoil energy data, taking into account the parameters of the EFT interactions and optimizing the data selection with respect to the dominant background components. Energy regions within 5$σ$ of known activation peaks were removed from the analysis. The Bayesian evidences resulting from the different operator hypotheses show that the CDMSlite Run 2 data are consistent with the background-only models and do not allow for a signal interpretation assuming any additional EFT interaction. Consequently, upper limits on the WIMP mass and coupling-coefficient amplitudes and phases are presented for each EFT operator. These limits improve previous CDMSlite Run 2 bounds for WIMP masses above 5 GeV/$c^2$.

preprint2022arXiv

Stable and high quality electron beams from staged laser and plasma wakefield accelerators

We present experimental results on a plasma wakefield accelerator (PWFA) driven by high-current electron beams from a laser wakefield accelerator (LWFA). In this staged setup stable and high quality (low divergence and low energy spread) electron beams are generated at an optically-generated hydrodynamic shock in the PWFA. The energy stability of the beams produced by that arrangement in the PWFA stage is comparable to both single-stage laser accelerators and plasma wakefield accelerators driven by conventional accelerators. Simulations support that the intrinsic insensitivity of PWFAs to driver energy fluctuations can be exploited to overcome stability limitations of state-of-the-art laser wakefield accelerators when adding a PWFA stage. Furthermore, we demonstrate the generation of electron bunches with energy spread and divergence superior to single-stage LW-FAs, resulting in bunches with dense phase space and an angular-spectral charge density beyond the initial drive beam parameters. These results unambiguously show that staged LWFA-PWFA can help to tailor the electron-beam quality for certain applications and to reduce the influence of fluctuating laser drivers on the electron-beam stability. This encourages further development of this new class of staged wakefield acceleration as a viable scheme towards compact, high-quality electron beam sources.

preprint2021arXiv

Constraints on dark photons and axion-like particles from SuperCDMS Soudan

We present an analysis of electron recoils in cryogenic germanium detectors operated during the SuperCDMS Soudan experiment. The data are used to set new constraints on the axioelectric coupling of axion-like particles and the kinetic mixing parameter of dark photons, assuming the respective species constitutes all of the galactic dark matter. This study covers the mass range from 40 eV/$c^2$ to 500 eV/$c^2$ for both candidates, excluding previously untested parameter space for masses below ~1 keV/$c^2$. For the kinetic mixing of dark photons, values below $10^{-15}$ are reached for particle masses around 100 eV/$c^2$; for the axioelectric coupling of axion-like particles, values below $10^{-12}$ are reached for particles with masses in the range of a few-hundred eV/$c^2$.

preprint2021arXiv

Constraints on low-mass, relic dark matter candidates from a surface-operated SuperCDMS single-charge sensitive detector

This article presents an analysis and the resulting limits on light dark matter inelastically scattering off of electrons, and on dark photon and axion-like particle absorption, using a second-generation SuperCDMS high-voltage eV-resolution detector. The 0.93 gram Si detector achieved a 3 eV phonon energy resolution; for a detector bias of 100 V, this corresponds to a charge resolution of 3% of a single electron-hole pair. The energy spectrum is reported from a blind analysis with 1.2 gram-days of exposure acquired in an above-ground laboratory. With charge carrier trapping and impact ionization effects incorporated into the dark matter signal models, the dark matter-electron cross section $\barσ_{e}$ is constrained for dark matter masses from 0.5--$10^{4} $MeV$/c^{2}$; in the mass range from 1.2--50 eV$/c^{2}$ the dark photon kinetic mixing parameter $\varepsilon$ and the axioelectric coupling constant $g_{ae}$ are constrained. The minimum 90% confidence-level upper limits within the above mentioned mass ranges are $\barσ_{e}\,=\,8.7\times10^{-34}$ cm$^{2}$, $\varepsilon\,=\,3.3\times10^{-14}$, and $g_{ae}\,=\,1.0\times10^{-9}$.

preprint2021arXiv

Search for Low-Mass Dark Matter with CDMSlite Using a Profile Likelihood Fit

The Cryogenic Dark Matter Search low ionization threshold experiment (CDMSlite) searches for interactions between dark matter particles and germanium nuclei in cryogenic detectors. The experiment has achieved a low energy threshold with improved sensitivity to low-mass (<10 GeV/c$^2$) dark matter particles. We present an analysis of the final CDMSlite data set, taken with a different detector than was used for the two previous CDMSlite data sets. This analysis includes a data &#34;salting&#34; method to protect against bias, improved noise discrimination, background modeling, and the use of profile likelihood methods to search for a dark matter signal in the presence of backgrounds. We achieve an energy threshold of 70 eV and significantly improve the sensitivity for dark matter particles with masses between 2.5 and 10 GeV/c$^2$ compared to previous analyses. We set an upper limit on the dark matter-nucleon scattering cross section in germanium of 5.4$\times$10$^{-42}$ cm$^2$ at 5 GeV/c$^2$, a factor of $\sim$2.5 improvement over the previous CDMSlite result.

preprint2020arXiv

A More Efficient Search for H2O Megamaser Galaxies : The Power of the X-ray and Mid-infrared Photometry

We present a new investigation of the dependence of H2O maser detection rates and properties on the mid-IR AGN luminosity, L_AGN, and the obscuring column density, N_H, based on mid-IR and hard X-ray photometry. Based on spectral energy distribution fitting that allows for decomposition of the black hole accretion and star-formation components in the mid-infrared, we show that the megamaser (disk maser) detection rate increases sharply for galaxies with 12 micron AGN luminosity L^{AGN}_{12 micron} greater than 10^42 erg/s, from ~<3%(~<2%) to ~12%(~5%). By using the ratio of the observed X-ray to mid-IR AGN luminosity as an indicator of N_H, we also find that the megamaser (disk maser) detection rates are boosted to 15%(7%) and 20%(9%) for galaxies with N_H >= 10^23 cm^{-2} and N_H >= 10^{24} cm^{-2}, respectively. Combining these column density cuts with a constraint for high L^{AGN}_{12 micron} (>=10^42 erg/s) predicts further increases in the megamaser (disk maser) detection rates to 19%(8%) and 27%(14%), revealing unprecedented potential boosts of the megamaser and disk maser detection rates by a factor of 7-15 relative to the current rates, depending on the chosen sample selection criteria. A noteworthy aspect of these new predictions is that the completeness rates are only compromised mildly, with the rates remaining at the level of ~95%(~50%) for sources with N_H >= 10^{23} cm^{-2} (N_H >= 10^24 cm^-2). Applying these selection methods to the current X-ray AGN surveys predicts the detection of >~15 new megamaser disks.

preprint2019arXiv

Probing Ultrafast Magnetic-Field Generation by Current Filamentation Instability in Femtosecond Relativistic Laser-Matter Interactions

We present experimental measurements of the femtosecond time-scale generation of strong magnetic-field fluctuations during the interaction of ultrashort, moderately relativistic laser pulses with solid targets. These fields were probed using low-emittance, highly relativistic electron bunches from a laser wakefield accelerator, and a line-integrated $B$-field of $2.70 \pm 0.39\,\rm kT\,μm$ was measured. Three-dimensional, fully relativistic particle-in-cell simulations indicate that such fluctuations originate from a Weibel-type current filamentation instability developing at submicron scales around the irradiated target surface, and that they grow to amplitudes strong enough to broaden the angular distribution of the probe electron bunch a few tens of femtoseconds after the laser pulse maximum. Our results highlight the potential of wakefield-accelerated electron beams for ultrafast probing of relativistic laser-driven phenomena.

preprint2019arXiv

Universal Non-equilibrium I-V Curve Near Two-channel Kondo-Luttinger Quantum Critical Point

The Fermi liquid paradigm for metals has contributed enormously to our understanding of condensed matter systems. However a growing number of quantum critical systems have been shown to exhibit non Fermi liquid behavior. A full understanding of such systems is still lacking and in particular analytical results away from equilibrium are rare. In this work, we provide a distinct example of such kind in a two channel Kondo Luttinger model where a Kondo impurity couples to two voltage biased interacting electron leads, experimentally realizable in a dissipative quantum dot. An exotic quantum phase transition has been known to exist for two decades from the one channel to two channel Kondo ground states by enhancing electron interactions in the leads, but a controlled theoretical approach to this quantum critical point has not yet been established. We present a controlled method to this problem and obtain an analytical form for the universal nonequilibrium differential conductance near the transition. The relevance of our results for recent experiments is discussed.