Source author record

Y. L. Yang

Y. L. Yang appears in the imported research catalog. Authorship, coauthor and topic links are available while profile ownership is still unclaimed.

ResearcherUnclaimed source record

Catalog footprint

What is connected

2works
2topics
4close collaborators

Actions

Connect this record

Log in to claim

Research graph

See the researcher in context

Open full explorer

Inspect adjacent papers, topics, institutions and collaborators without losing the researcher page.

Building this map preview

BZPEER is loading the nearby papers, people, topics and institutions for this page.

Published work

2 published item(s)

preprint2022arXiv

Nuclear landscape in a mapped collective Hamiltonian from covariant density functional theory

The nuclear landscape has been investigated within the triaxial relativistic Hartree-Bogoliubov theory with the PC-PK1 density functional, and the beyond-mean-field dynamical correlation energies are taken into account by a microscopically mapped five-dimensional collective Hamiltonian without additional free parameters. The effects of triaxial deformation and dynamical correlations on the nuclear landscape are analyzed. The present results provide the best description of the experimental binding energies, in particular for medium and heavy mass regions, in comparison with the results obtained previously with other state-of-the-art covariant density functionals. The inclusion of the dynamical correlation energies plays an important role in the PC-PK1 results. It is emphasized that the nuclear landscape is considerably extended by the PC-PK1 functional in comparison with the previous results with other density functionals, which may be due to the different isovector properties in the density functionals.

preprint2013arXiv

A new measurement method of electrode gains for orthogonal symmetric type beam position monitor

The new beam position monitor (BPM) system of the injector at the upgrade project of Hefei Light Source (HLS II) has 19 stripline beam position monitors. Most consist of four orthogonal symmetric stripline electrodes. The differences in electronic gain and mismachining tolerance can cause the change of the beam response of the BPM electrodes. This variation will couple the two measured horizontal positions in order to bring the measuring error. To alleviate this effect, a new technique to measure the relative response of the four electrodes has been developed. It is irrelevant to the beam charge and the related coefficient can be theoretical calculated. The effect of electrodes coupling on this technique is analyzed. The calibration data is used to fit the gain for all 19 injector beam position monitors. The results show the standard deviation of the distribution of measured gains is about 5%.