Researcher profile

Y. Kok

Y. Kok contributes to research discovery and scholarly infrastructure.

ResearcherAffiliation not importedOpen to collaborate

Trust snapshot

Quick read

Trust 21 - EmergingVerification L1Unclaimed author
12works
0followers
2topics
4close collaborators

Actions

Decide how to stay connected

Follow researcher0

Identity and collaboration

How to connect with this researcher

Claiming links this public author record to a researcher profile and unlocks direct collaboration workflows.

Log in to claim

Direct collaboration

Open a focused conversation when the fit is right

Claim this author entity first to unlock direct invitations.

Research graph

See the researcher in context

Open full explorer

Inspect adjacent work, topics, institutions and collaborators without jumping out to a separate graph page.

Building this graph slice

BZPEER is loading the nearby papers, people, topics and institutions for this page.

Published work

12 published item(s)

preprint2015arXiv

GRAVITY: the VLTI 4-beam combiner for narrow-angle astrometry and interferometric imaging

GRAVITY is the second generation Very Large Telescope Interferometer instrument for precision narrow-angle astrometry and interferometric imaging in the Near Infra-Red (NIR). It shall provide precision astrometry of order 10 microarcseconds, and imaging capability at a few milliarcsecond resolution, and hence will revolutionise dynamical measurements of celestial objects. GRAVITY is currently in the last stages of its integration and tests in Garching at MPE, and will be delivered to the VLT Interferometer (VLTI) in 2015. We present here the instrument, with a particular focus on the components making use of fibres: integrated optics beam combiners, polarisation rotators, fibre differential delay lines, and the metrology.

preprint2015arXiv

The GRAVITY metrology system: narrow-angle astrometry via phase-shifting interferometry

The VLTI instrument GRAVITY will provide very powerful astrometry by combining the light from four telescopes for two objects simultaneously. It will measure the angular separation between the two astronomical objects to a precision of 10 microarcseconds. This corresponds to a differential optical path difference (dOPD) between the targets of few nanometers and the paths within the interferometer have to be maintained stable to that level. For this purpose, the novel metrology system of GRAVITY will monitor the internal dOPDs by means of phase-shifting interferometry. We present the four-step phase-shifting concept of the metrology with emphasis on the method used for calibrating the phase shifts. The latter is based on a phase-step insensitive algorithm which unambiguously extracts phases in contrast to other methods that are strongly limited by non-linearities of the phase-shifting device. The main constraint of this algorithm is to introduce a robust ellipse fitting routine. Via this approach we are able to measure phase shifts in the laboratory with a typical accuracy of lambda/2000 or 1 nanometer of the metrology wavelength.

preprint2014arXiv

Alternative approach to precision narrow-angle astrometry for Antarctic long baseline interferometry

The conventional approach to high-precision narrow-angle astrometry using a long baseline interferometer is to directly measure the fringe packet separation of a target and a nearby reference star. This is done by means of a technique known as phase-referencing which requires a network of dual beam combiners and laser metrology systems. Using an alternative approach that does not rely on phase-referencing, the narrow-angle astrometry of several closed binary stars (with separation less than 2$"$), as described in this paper, was carried out by observing the fringe packet crossing event of the binary systems. Such an event occurs twice every sidereal day when the line joining the two stars of the binary is is perpendicular to the projected baseline of the interferometer. Observation of these events is well suited for an interferometer in Antarctica. Proof of concept observations were carried out at the Sydney University Stellar Interferometer (SUSI) with targets selected according to its geographical location. Narrow-angle astrometry using this indirect approach has achieved sub-100 micro-arcsecond precision.

preprint2014arXiv

GRAVITY: the Calibration Unit

We present in this paper the design and characterisation of a new sub-system of the VLTI 2nd generation instrument GRAVITY: the Calibration Unit. The Calibration Unit provides all functions to test and calibrate the beam combiner instrument: it creates two artificial stars on four beams, and dispose of four delay lines with an internal metrology. It also includes artificial stars for the tip-tilt and pupil guiding systems, as well as four metrology pick-up diodes, for tests and calibration of the corresponding sub-systems. The calibration unit also hosts the reference targets to align GRAVITY to the VLTI, and the safety shutters to avoid the metrology light to propagate in the VLTI-lab. We present the results of the characterisation and validtion of these differrent sub-units.

preprint2014arXiv

Reaching micro-arcsecond astrometry with long baseline optical interferometry; application to the GRAVITY instrument

A basic principle of long baseline interferometry is that an optical path difference (OPD) directly translates into an astrometric measurement. In the simplest case, the OPD is equal to the scalar product between the vector linking the two telescopes and the normalized vector pointing toward the star. However, a too simple interpretation of this scalar product leads to seemingly conflicting results, called here "the baseline paradox". For micro-arcsecond accuracy astrometry, we have to model in full the metrology measurement. It involves a complex system subject to many optical effects: from pure baseline errors to static, quasi-static and high order optical aberrations. The goal of this paper is to present the strategy used by the "General Relativity Analysis via VLT InTerferometrY" instrument (GRAVITY) to minimize the biases introduced by these defects. It is possible to give an analytical formula on how the baselines and tip-tilt errors affect the astrometric measurement. This formula depends on the limit-points of three type of baselines: the wide-angle baseline, the narrow-angle baseline, and the imaging baseline. We also, numerically, include non-common path higher-order aberrations, whose amplitude were measured during technical time at the Very Large Telescope Interferometer. We end by simulating the influence of high-order common-path aberrations due to atmospheric residuals calculated from a Monte-Carlo simulation tool for Adaptive optics systems. The result of this work is an error budget of the biases caused by the multiple optical imperfections, including optical dispersion. We show that the beam stabilization through both focal and pupil tracking is crucial to the GRAVITY system. Assuming the instrument pupil is stabilized at a 4 cm level on M1, and a field tracking below 0.2$λ/D$, we show that GRAVITY will be able to reach its objective of 10$μ$as accuracy.

preprint2014arXiv

The fiber coupler and beam stabilization system of the GRAVITY interferometer

We present the installed and fully operational beam stabilization and fiber injection subsystem feeding the 2nd generation VLTI instrument GRAVITY. The interferometer GRAVITY requires an unprecedented stability of the VLTI optical train to achieve micro-arcsecond astrometry. For this purpose, GRAVITY contains four fiber coupler units, one per telescope. Each unit is equipped with actuators to stabilize the telescope beam in terms of tilt and lateral pupil displacement, to rotate the field, to adjust the polarization and to compensate atmospheric piston. A special roof-prism offers the possibility of on-axis as well as off-axis fringe tracking without changing the optical train. We describe the assembly, integration and alignment and the resulting optical quality and performance of the individual units. Finally, we present the closed-loop performance of the tip-tilt and pupil tracking achieved with the final systems in the lab.

preprint2014arXiv

The GRAVITY metrology system: modeling a metrology in optical fibers

GRAVITY is the second generation VLT Interferometer (VLTI) instrument for high-precision narrow-angle astrometry and phase-referenced interferometric imaging. The laser metrology system of GRAVITY is at the heart of its astrometric mode, which must measure the distance of 2 stars with a precision of 10 micro-arcseconds. This means the metrology has to measure the optical path difference between the two beam combiners of GRAVITY to a level of 5 nm. The metrology design presents some non-common paths that have consequently to be stable at a level of 1 nm. Otherwise they would impact the performance of GRAVITY. The various tests we made in the past on the prototype give us hints on the components responsible for this error, and on their respective contribution to the total error. It is however difficult to assess their exact origin from only OPD measurements, and therefore, to propose a solution to this problem. In this paper, we present the results of a semi-empirical modeling of the fibered metrology system, relying on theoretical basis, as well as on characterisations of key components. The modeling of the metrology system regarding various effects, e.g., temperature, waveguide heating or mechanical stress, will help us to understand how the metrology behave. The goals of this modeling are to 1) model the test set-ups and reproduce the measurements (as a validation of the modeling), 2) determine the origin of the non-common path errors, and 3) propose modifications to the current metrology design to reach the required 1nm stability.

preprint2014arXiv

The interferometric baselines and GRAVITY astrometric error budget

GRAVITY is a new generation beam combination instrument for the VLTI. Its goal is to achieve microarsecond astrometric accuracy between objects separated by a few arcsec. This $10^6$ accuracy on astrometric measurements is the most important challenge of the instrument, and careful error budget have been paramount during the technical design of the instrument. In this poster, we will focus on baselines induced errors, which is part of a larger error budget.

preprint2013arXiv

Long-Baseline Interferometric Multiplicity Survey of the Sco-Cen OB Association

We present the first multiplicity-dedicated long baseline optical interferometric survey of the Scorpius-Centaurus-Lupus-Crux association. We used the Sydney University Stellar Interferometer to undertake a survey for new companions to 58 Sco-Cen B- type stars and have detected 24 companions at separations ranging from 7-130mas, 14 of which are new detections. Furthermore, we use a Bayesian analysis and all available information in the literature to determine the multiplicity distribution of the 58 stars in our sample, showing that the companion frequency is F = 1.35 and the mass ratio distribution is best described as a power law with exponent equal to -0.46, agreeing with previous Sco-Cen high mass work and differing significantly from lower-mass stars in Tau-Aur. Based on our analysis, we estimate that among young B-type stars in moving groups, up to 23% are apparently single stars. This has strong implications for the understanding of high-mass star formation, which requires angular momentum dispersal through some mechanism such as formation of multiple systems.

preprint2013arXiv

Optical Interferometry of early-type stars with PAVO@CHARA. I. Fundamental stellar properties

We present interferometric observations of 7 main-sequence and 3 giant stars with spectral types from B2 to F6 using the PAVO beam combiner at the CHARA array. We have directly determined the angular diameters for these objects with an average precision of 2.3%. We have also computed bolometric fluxes using available photometry in the visible and infrared wavelengths, as well as space-based ultraviolet spectroscopy. Combined with precise \textit{Hipparcos} parallaxes, we have derived a set of fundamental stellar properties including linear radius, luminosity and effective temperature. Fitting the latter to computed isochrone models, we have inferred masses and ages of the stars. The effective temperatures obtained are in good agreement (at a 3% level) with nearly-independent temperature estimations from spectroscopy. They validate recent sixth-order polynomial (B-V)-$T_\mathrm{eff}$ empirical relations \citep{Boyajian2012a}, but suggest that a more conservative third-order solution \citep{vanBelle2009} could adequately describe the (V-K)-$T_\mathrm{eff}$ relation for main-sequence stars of spectral type A0 and later. Finally, we have compared mass values obtained combining surface gravity with inferred stellar radius (\textit{gravity mass}) and as a result of the comparison of computed luminosity and temperature values with stellar evolutionary models (\textit{isochrone mass}). The strong discrepancy between isochrone and gravity mass obtained for one of the observed stars, $γ$\,Lyr, suggests that determination of the stellar atmosphere parameters should be revised.

preprint2013arXiv

Phase-referenced Interferometry and Narrow-angle Astrometry with SUSI

The Sydney University Stellar Interferometer (SUSI) now incorporates a new beam combiner, called the Microarcsecond University of Sydney Companion Astrometry instrument (MUSCA), for the purpose of high precision differential astrometry of bright binary stars. Operating in the visible wavelength regime where photon-counting and post-processing fringe tracking is possible, MUSCA will be used in tandem with SUSI's primary beam combiner, Precision Astronomical Visible Observations (PAVO), to record high spatial resolution fringes and thereby measure the separation of fringe packets of binary stars. In its current phase of development, the dual beam combiner configuration has successfully demonstrated for the first time a dual-star phase-referencing operation in visible wavelengths. This paper describes the beam combiner optics and hardware, the network of metrology systems employed to measure every non-common path between the two beam combiners and also reports on a recent narrow-angle astrometric observation of $δ$ Orionis A (HR 1852) as the project enters its on-sky testing phase.

preprint2013arXiv

Searching for solar-like oscillations in the delta Scuti star rho Puppis

Despite the shallow convective envelopes of delta Scuti pulsators, solar-like oscillations are theoretically predicted to be excited in those stars as well. To search for such stochastic oscillations we organised a spectroscopic multi-site campaign for the bright, metal-rich delta Sct star rho Puppis. We obtained a total of 2763 high-resolution spectra using four telescopes. We discuss the reduction and analysis with the iodine cell technique, developed for searching for low-amplitude radial velocity variations, in the presence of high-amplitude variability. Furthermore, we have determined the angular diameter of rho Puppis to be 1.68 \pm 0.03 mas, translating into a radius of 3.52 \pm 0.07Rsun. Using this value, the frequency of maximum power of possible solar-like oscillations, is expected at ~43 \pm 2 c/d (498 \pm 23 muHz). The dominant delta Scuti-type pulsation mode of rho Puppis is known to be the radial fundamental mode which allows us to determine the mean density of the star, and therefore an expected large frequency separation of 2.73 c/d (31.6 muHz). We conclude that 1) the radial velocity amplitudes of the delta Scuti pulsations are different for different spectral lines; 2) we can exclude solar-like oscillations to be present in rho Puppis with an amplitude per radial mode larger than 0.5 m/s.