Source author record

Y. -C. Cheng

Y. -C. Cheng appears in the imported research catalog. Authorship, coauthor and topic links are available while profile ownership is still unclaimed.

ResearcherUnclaimed source record

Catalog footprint

What is connected

2works
2topics
4close collaborators

Actions

Connect this record

Log in to claim

Research graph

See the researcher in context

Open full explorer

Inspect adjacent papers, topics, institutions and collaborators without losing the researcher page.

Building this map preview

BZPEER is loading the nearby papers, people, topics and institutions for this page.

Published work

2 published item(s)

preprint2022arXiv

Water Ortho-to-Para ratio in the coma of comet 67P/Churyumov-Gerasimenko

Abundance ratios of the nuclear-spin isomers of H$_2$O and NH$_3$ have been measured in about two dozen comets, with a mean value corresponding to a nuclear-spin temperature of $\sim$ 30 K. The real meaning of these unequilibrated nuclear-spin abundance ratios is still debated. However, an equilibrated water ortho-to-para ratio (OPR) of 3 is also commonly observed. The H channel of VIRTIS (VIRTIS-H) on board Rosetta provided high-resolution 2.5--2.9 $μ$m spectra of H$_2$O vapour in the coma of comet 67P/Churyumov-Gerasimenko (67P), which are suitable for the determination of the OPR of water in this comet. A large dataset of VIRTIS-H spectra obtained in limb-sounding viewing geometry was analysed, covering heliocentric distances from 1.24 to 2.73 au and altitudes from a few hundred metres to $>$ 100 km. The OPR, together with the H$_2$O rotational temperature and column density, were derived for each spectra. The weak lines of the $ν_1$, $ν_1+ν_3-ν_1$ and $ν_2+ν_3-ν_2$ bands in the 2.774--2.910 $μ$m range were used to calculate by how much the strong $ν_3$ band centred at 2.67 $μ$m is attenuated due to optical depth effects, expressed by the attenuation factor $f_{\rm atten}$. Most OPR determinations are strongly affected by opacity effects, as demonstrated by the observed anti-correlation between the OPR and the column density, and the correlation between the OPR and attenuation factor $f_{\rm atten}$. Based on both radiative transfer calculations and OPR values obtained in low-opacity conditions, we derive an OPR of 2.94 $\pm$ 0.06 for comet 67P. The water OPR measured in the coma of 67P is consistent with laboratory experiments showing that water vapour that has thermally desorbed from water ice has a statistical value of 3, regardless of the past formation process of water ice.