Source author record

Xiaozhou Yang

Xiaozhou Yang appears in the imported research catalog. Authorship, coauthor and topic links are available while profile ownership is still unclaimed.

ResearcherUnclaimed source record

Catalog footprint

What is connected

3works
3topics
2close collaborators

Actions

Connect this record

Log in to claim

Research graph

See the researcher in context

Open full explorer

Inspect adjacent papers, topics, institutions and collaborators without losing the researcher page.

Building this map preview

BZPEER is loading the nearby papers, people, topics and institutions for this page.

Published work

3 published item(s)

preprint2022arXiv

LASSO-Based Multiple-Line Outage Identification In Partially Observable Power Systems

Phasor measurement units (PMUs) create ample real-time monitoring opportunities for modern power systems. Among them, line outage detection and identification remains a crucial but challenging task. Current works on outage identification succeed in full PMU deployment and single-line outages. Performance however degrades for multiple-line outage with partial system observability. We propose a novel framework of multiple-line outage identification using partial nodal voltage measurements. Using alternating current (AC) power flow model, phase angle signatures of outages are extracted and used to group lines into minimal diagnosable clusters. Identification is then formulated into an underdetermined sparse regression problem solved by lasso. Tested on IEEE 39-bus system with 25% and 50% PMU coverage, the proposed identification method is 93% and 80% accurate for single- and double-line outages. Our study suggests that the AC power flow is better at capturing outage patterns and sacrificing some precision could yield substantial improvement in identification accuracy. These findings could contribute to the development of future control schemes that help power systems resist and recover from outage disruptions in real time.

preprint2020arXiv

A Control Chart Approach to Power System Line Outage Detection Under Transient Dynamics

Online transmission line outage detection over the entire network enables timely corrective action to be taken, which prevents a local event from cascading into a large scale blackout. Line outage detection aims to detect an outage as soon as possible after it happened. Traditional methods either do not consider the transient dynamics following an outage or require a full Phasor Measurement Unit (PMU) deployment. Using voltage phase angle data collected from a limited number of PMUs, we propose a real-time dynamic outage detection scheme based on alternating current (AC) power flow model and statistical change detection theory. The proposed method can capture system dynamics since it retains the time-variant and nonlinear nature of the power system. The method is computationally efficient and scales to large and realistic networks. Extensive simulation studies on IEEE 39-bus and 2383-bus systems demonstrated the effectiveness of the proposed method.

preprint2020arXiv

Optimal Placement of Limited PMUs for Transmission Line Outage Detection and Identification

Phasor Measurement Unit (PMU) technology is increasingly used for real-time monitoring applications, especially line outage detection and identification (D&I) in the power system. Current outage D&I schemes either assume a full PMU deployment or a partial deployment with fixed PMU placement. However, the placement of the PMUs has a fundamental impact on the effectiveness of the D&I scheme. Building on a dynamic relationship between the substation voltage phase angle and active power, we formulated the optimal PMU placement problem for outage D&I as an optimization problem readily solvable by any heuristic algorithm. We tested the formulation using a genetic algorithm and simulated outages of IEEE 39 bus system. The optimal placement found produces a better D&I result of single-line outages than a randomly scattered, tree-like, and degree-based placements.