Source author record

Xiaoguang Cheng

Xiaoguang Cheng appears in the imported research catalog. Authorship, coauthor and topic links are available while profile ownership is still unclaimed.

ResearcherUnclaimed source record

Catalog footprint

What is connected

1works
2topics
4close collaborators

Actions

Connect this record

Log in to claim

Research graph

See the researcher in context

Open full explorer

Inspect adjacent papers, topics, institutions and collaborators without losing the researcher page.

Building this map preview

BZPEER is loading the nearby papers, people, topics and institutions for this page.

Published work

1 published item(s)

preprint2021arXiv

A Deep Learning-Based Approach to Extracting Periosteal and Endosteal Contours of Proximal Femur in Quantitative CT Images

Automatic CT segmentation of proximal femur is crucial for the diagnosis and risk stratification of orthopedic diseases; however, current methods for the femur CT segmentation mainly rely on manual interactive segmentation, which is time-consuming and has limitations in both accuracy and reproducibility. In this study, we proposed an approach based on deep learning for the automatic extraction of the periosteal and endosteal contours of proximal femur in order to differentiate cortical and trabecular bone compartments. A three-dimensional (3D) end-to-end fully convolutional neural network, which can better combine the information between neighbor slices and get more accurate segmentation results, was developed for our segmentation task. 100 subjects aged from 50 to 87 years with 24,399 slices of proximal femur CT images were enrolled in this study. The separation of cortical and trabecular bone derived from the QCT software MIAF-Femur was used as the segmentation reference. We randomly divided the whole dataset into a training set with 85 subjects for 10-fold cross-validation and a test set with 15 subjects for evaluating the performance of models. Two models with the same network structures were trained and they achieved a dice similarity coefficient (DSC) of 97.87% and 96.49% for the periosteal and endosteal contours, respectively. To verify the excellent performance of our model for femoral segmentation, we measured the volume of different parts of the femur and compared it with the ground truth and the relative errors between predicted result and ground truth are all less than 5%. It demonstrated a strong potential for clinical use, including the hip fracture risk prediction and finite element analysis.