17 published item(s)

preprint2022arXiv

Mass Testing and Characterization of 20-inch PMTs for JUNO

Main goal of the JUNO experiment is to determine the neutrino mass ordering using a 20kt liquid-scintillator detector. Its key feature is an excellent energy resolution of at least 3 % at 1 MeV, for which its instruments need to meet a certain quality and thus have to be fully characterized. More than 20,000 20-inch PMTs have been received and assessed by JUNO after a detailed testing program which began in 2017 and elapsed for about four years. Based on this mass characterization and a set of specific requirements, a good quality of all accepted PMTs could be ascertained. This paper presents the performed testing procedure with the designed testing systems as well as the statistical characteristics of all 20-inch PMTs intended to be used in the JUNO experiment, covering more than fifteen performance parameters including the photocathode uniformity. This constitutes the largest sample of 20-inch PMTs ever produced and studied in detail to date, i.e. 15,000 of the newly developed 20-inch MCP-PMTs from Northern Night Vision Technology Co. (NNVT) and 5,000 of dynode PMTs from Hamamatsu Photonics K. K.(HPK).

preprint2021arXiv

Development of water extraction system for liquid scintillatorpurification of JUNO

The Jiangmen Underground Neutrino Observatory (JUNO) uses 20k tons of liquid scintillator (LS)to detect neutrinos. The content of radioactive substances in the liquid scintillator will affect theexperimental results. JUNO will use counter current water extraction to reduce the radioactive metalions inside the LS. In this article, The factors that affect the final water extraction like the partitioncoefficient and the factors that affect it, the optimal mass transfer droplet size, the flow rate ratio,theoretical stage and different working mode (LS as continuous phase or dispersed phase) have beenstudied. We built counter current extraction prototype in the laboratory and a pilot plant in Daya Bay.We not only study the factors above, but also get a lot of engineering experience that worth sharing.

preprint2021arXiv

JUNO Physics and Detector

The Jiangmen Underground Neutrino Observatory (JUNO) is a 20 kton LS detector at 700-m underground. An excellent energy resolution and a large fiducial volume offer exciting opportunities for addressing many important topics in neutrino and astro-particle physics. With 6 years of data, the neutrino mass ordering can be determined at 3-4 sigma and three oscillation parameters can be measured to a precision of 0.6% or better by detecting reactor antineutrinos. With 10 years of data, DSNB could be observed at 3-sigma; a lower limit of the proton lifetime of 8.34e33 years (90% C.L.) can be set by searching for p->nu_bar K^+; detection of solar neutrinos would shed new light on the solar metallicity problem and examine the vacuum-matter transition region. A core-collapse supernova at 10 kpc would lead to ~5000 IBD and ~2000 (300) all-flavor neutrino-proton (electron) scattering events. Geo-neutrinos can be detected with a rate of ~400 events/year. We also summarize the final design of the JUNO detector and the key R&D achievements. All 20-inch PMTs have been tested. The average photon detection efficiency is 28.9% for the 15,000 MCP PMTs and 28.1% for the 5,000 dynode PMTs, higher than the JUNO requirement of 27%. Together with the >20 m attenuation length of LS, we expect a yield of 1345 p.e. per MeV and an effective energy resolution of 3.02%/\sqrt{E (MeV)}$ in simulations. The underwater electronics is designed to have a loss rate <0.5% in 6 years. With degassing membranes and a micro-bubble system, the radon concentration in the 35-kton water pool could be lowered to <10 mBq/m^3. Acrylic panels of radiopurity <0.5 ppt U/Th are produced. The 20-kton LS will be purified onsite. Singles in the fiducial volume can be controlled to ~10 Hz. The JUNO experiment also features a double calorimeter system with 25,600 3-inch PMTs, a LS testing facility OSIRIS, and a near detector TAO.

preprint2020arXiv

Feasibility and physics potential of detecting $^8$B solar neutrinos at JUNO

The Jiangmen Underground Neutrino Observatory~(JUNO) features a 20~kt multi-purpose underground liquid scintillator sphere as its main detector. Some of JUNO's features make it an excellent experiment for $^8$B solar neutrino measurements, such as its low-energy threshold, its high energy resolution compared to water Cherenkov detectors, and its much large target mass compared to previous liquid scintillator detectors. In this paper we present a comprehensive assessment of JUNO's potential for detecting $^8$B solar neutrinos via the neutrino-electron elastic scattering process. A reduced 2~MeV threshold on the recoil electron energy is found to be achievable assuming the intrinsic radioactive background $^{238}$U and $^{232}$Th in the liquid scintillator can be controlled to 10$^{-17}$~g/g. With ten years of data taking, about 60,000 signal and 30,000 background events are expected. This large sample will enable an examination of the distortion of the recoil electron spectrum that is dominated by the neutrino flavor transformation in the dense solar matter, which will shed new light on the tension between the measured electron spectra and the predictions of the standard three-flavor neutrino oscillation framework. If $Δm^{2}_{21}=4.8\times10^{-5}~(7.5\times10^{-5})$~eV$^{2}$, JUNO can provide evidence of neutrino oscillation in the Earth at the about 3$σ$~(2$σ$) level by measuring the non-zero signal rate variation with respect to the solar zenith angle. Moveover, JUNO can simultaneously measure $Δm^2_{21}$ using $^8$B solar neutrinos to a precision of 20\% or better depending on the central value and to sub-percent precision using reactor antineutrinos. A comparison of these two measurements from the same detector will help elucidate the current tension between the value of $Δm^2_{21}$ reported by solar neutrino experiments and the KamLAND experiment.

preprint2020arXiv

TAO Conceptual Design Report: A Precision Measurement of the Reactor Antineutrino Spectrum with Sub-percent Energy Resolution

The Taishan Antineutrino Observatory (TAO, also known as JUNO-TAO) is a satellite experiment of the Jiangmen Underground Neutrino Observatory (JUNO). A ton-level liquid scintillator detector will be placed at about 30 m from a core of the Taishan Nuclear Power Plant. The reactor antineutrino spectrum will be measured with sub-percent energy resolution, to provide a reference spectrum for future reactor neutrino experiments, and to provide a benchmark measurement to test nuclear databases. A spherical acrylic vessel containing 2.8 ton gadolinium-doped liquid scintillator will be viewed by 10 m^2 Silicon Photomultipliers (SiPMs) of >50% photon detection efficiency with almost full coverage. The photoelectron yield is about 4500 per MeV, an order higher than any existing large-scale liquid scintillator detectors. The detector operates at -50 degree C to lower the dark noise of SiPMs to an acceptable level. The detector will measure about 2000 reactor antineutrinos per day, and is designed to be well shielded from cosmogenic backgrounds and ambient radioactivities to have about 10% background-to-signal ratio. The experiment is expected to start operation in 2022.

preprint2019arXiv

Hyperpolarized relaxometry based nuclear T1 noise spectroscopy in hybrid diamond quantum registers

Understanding the origins of spin lifetimes in hybrid quantum systems is a matter of current importance in several areas of quantum information and sensing. Methods that spectrally map spin relaxation processes provide insight into their origin and can motivate methods to mitigate them. In this paper, using a combination of hyperpolarization and precision field cycling over a wide range (1mT-7T), we map frequency dependent relaxation in a prototypical hybrid system of 13C nuclear spins in diamond coupled to Nitrogen Vacancy centers. Nuclear hyperpolarization through the optically pumped NV electrons allows signal time savings for the measurements exceeding million-fold over conventional methods. We observe that 13C lifetimes show a dramatic field dependence, growing rapidly with field up to 100mT and saturating thereafter. Through a systematic study with increasing substitutional electron (P1 center) concentration as well as 13C enrichment levels, we identify the operational relaxation channels for the nuclei in different field regimes. In particular, we demonstrate the dominant role played by the 13C nuclei coupling to the interacting P1 electronic spin bath. These results pave the way for quantum control techniques for dissipation engineering to boost spin lifetimes in diamond, with applications ranging from engineered quantum memories to hyperpolarized 13C imaging.

preprint2016arXiv

A Closed Form Solution to Multi-View Low-Rank Regression

Real life data often includes information from different channels. For example, in computer vision, we can describe an image using different image features, such as pixel intensity, color, HOG, GIST feature, SIFT features, etc.. These different aspects of the same objects are often called multi-view (or multi-modal) data. Low-rank regression model has been proved to be an effective learning mechanism by exploring the low-rank structure of real life data. But previous low-rank regression model only works on single view data. In this paper, we propose a multi-view low-rank regression model by imposing low-rank constraints on multi-view regression model. Most importantly, we provide a closed-form solution to the multi-view low-rank regression model. Extensive experiments on 4 multi-view datasets show that the multi-view low-rank regression model outperforms single-view regression model and reveals that multi-view low-rank structure is very helpful.

preprint2016arXiv

The laboratory measurement of radioactivity purification for Pb212 in liquid scintillator

The liquid scintillator (LS) has been widely utilized in the past, running and future neutrino experiments, and requirement to the LS radio-purity is higher and higher. The water extraction is a powerful method to remove soluble radioactive nuclei, and a mini-extraction station has been constructed. To evaluate the extraction efficiency and optimize the operation parameters, a setup to load radioactivity to LS and a laboratory scale setup to measure radioactivity which use Bi^{212}-Po^{212}-Pb^{208} cascade decay are developed. Experiences from laboratory study will be useful to large scale water extraction plants design and the optimization of working in future.

preprint2015arXiv

Neutrino Physics with JUNO

The Jiangmen Underground Neutrino Observatory (JUNO), a 20 kton multi-purpose underground liquid scintillator detector, was proposed with the determination of the neutrino mass hierarchy as a primary physics goal. It is also capable of observing neutrinos from terrestrial and extra-terrestrial sources, including supernova burst neutrinos, diffuse supernova neutrino background, geoneutrinos, atmospheric neutrinos, solar neutrinos, as well as exotic searches such as nucleon decays, dark matter, sterile neutrinos, etc. We present the physics motivations and the anticipated performance of the JUNO detector for various proposed measurements. By detecting reactor antineutrinos from two power plants at 53-km distance, JUNO will determine the neutrino mass hierarchy at a 3-4 sigma significance with six years of running. The measurement of antineutrino spectrum will also lead to the precise determination of three out of the six oscillation parameters to an accuracy of better than 1\%. Neutrino burst from a typical core-collapse supernova at 10 kpc would lead to ~5000 inverse-beta-decay events and ~2000 all-flavor neutrino-proton elastic scattering events in JUNO. Detection of DSNB would provide valuable information on the cosmic star-formation rate and the average core-collapsed neutrino energy spectrum. Geo-neutrinos can be detected in JUNO with a rate of ~400 events per year, significantly improving the statistics of existing geoneutrino samples. The JUNO detector is sensitive to several exotic searches, e.g. proton decay via the $p\to K^++\barν$ decay channel. The JUNO detector will provide a unique facility to address many outstanding crucial questions in particle and astrophysics. It holds the great potential for further advancing our quest to understanding the fundamental properties of neutrinos, one of the building blocks of our Universe.

preprint2015arXiv

Upgrade of Beam Energy Measurement System at BEPC-II

The beam energy measurement system is of great importance and profit for both BEPC-II accelerator and BES-III detector. The system is based on measuring the energies of Compton back-scattered photons. Many advanced techniques and precise instruments are employed to realize the highly accurate measurement of positron/electron beam energy. During five year's running period, in order to meet the requirement of data taking and improve the capacity of measurement itself, the upgradation of system is continued, which involve the component reformation of laser and optics subsystem, replacement of view-port of the laser to vacuum insertion subsystem, the purchase of electric cooling system for high purity germanium detector, and the improvement of data acquisition and processing subsystem. The upgrading of system guarantees the smooth and efficient measuring of beam energy at BEPC-II and accommodates the accurate offline energy values for further physics analysis at BES-III.

preprint2014arXiv

Simulation and performance study of the ceramic THGEM

The THGEMs based on ceramic substrate were developed successfully for neutron and single photon detection. The influences on thermal neutron scattering and the internal radioactivity of both ceramic and FR-4 substrates were studied and compared. The ceramic THGEMs are homemade of 200 um hole diameter, 600 um pitch, 200 um thickness, 80 um rim, and 50 mm*50 mm sensitive area. The FR-4 THGEMs with the same geometry were used for the reference. The gas gain, energy resolution and gain stability were measured in different gas mixtures by using the 5.9 keV X-rays. The maximum gain of single layer ceramic THGEM reaches 6*104 and 1.5*104 at Ne+CH4 = 95:5 and Ar+i-C4H10 = 97:3, respectively. The energy resolution is better than 24%. The good gain stability was obtained during more than 100 hour continuous test at Ar+CO2 = 80:20. By using the 239Pu source, the alpha deposited energy spectrum and gain curve of ceramic THGEM were measured.

preprint2014arXiv

Simulation of background reduction and Compton depression in low-background HPGe spectrometer at a surface laboratory

High-purity germanium detectors are well suited to analysis the radioactivity of samples. In order to reduce the environmental background, low-activity lead and oxygen free copper are installed outside of the probe to shield gammas, outmost is a plastic scintillator to veto the cosmic rays, and an anti-Compton detector can improve the Peak-to-Compton ratio. Using the GEANT4 tools and taking into account a detailed description of the detector, we optimize the sizes of the detectors to reach the design indexes. A group of experimental data from a HPGe spectrometer in using were used to compare with the simulation. As to new HPGe Detector simulation, considering the different thickness of BGO crystals and anti-coincidence efficiency, the simulation results show that the optimal thickness is 5.5cm, and the Peak-to-Compton ratio of 40K is raised to 1000 when the anti-coincidence efficiency is 0.85. As the background simulation, 15 cm oxygen-free copper plus 10 cm lead can reduce the environmental gamma rays to 0.0024 cps/100 cm3 Ge (50keV~2.8MeV), which is about 10-5 of environmental background.

preprint2014arXiv

Soft Consistency Reconstruction: A Robust 1-bit Compressive Sensing Algorithm

A class of recovering algorithms for 1-bit compressive sensing (CS) named Soft Consistency Reconstructions (SCRs) are proposed. Recognizing that CS recovery is essentially an optimization problem, we endeavor to improve the characteristics of the objective function under noisy environments. With a family of re-designed consistency criteria, SCRs achieve remarkable counter-noise performance gain over the existing counterparts, thus acquiring the desired robustness in many real-world applications. The benefits of soft decisions are exemplified through structural analysis of the objective function, with intuition described for better understanding. As expected, through comparisons with existing methods in simulations, SCRs demonstrate preferable robustness against noise in low signal-to-noise ratio (SNR) regime, while maintaining comparable performance in high SNR regime.

preprint2011arXiv

Experimental study of THGEM detector with mini-rim

The gas gain and energy resolution of single and double THGEM detectors (5{\times}5cm2 effective area) with mini-rims (rim is less than 10μm) were studied. The maximum gain can reach 5{\times}103 and 2{\times}105 for single and double THGEM respectively, while the energy resolution of 5.9 keV X-ray varied from 18% to 28% for both single and double THGEM detectors of different hole sizes and thicknesses.All the experiments were investigated in mixture of noble gases(argon,neon) and small content of other gases(iso-butane,methane) at atmospheric pressure.

preprint2011arXiv

Neutron-gamma discrimination of CsI(Na) crystals for dark matter searches

The luminescent properties of CsI(Na) crystals are studied in this report. By using a TDS3054C oscilloscope with a sampling frequency of 5 GS/s, we find out that nuclear recoil signals are dominated by very fast light pulse with a decay time of ~20 ns, while γ-ray signals have a decay time of ~600 ns. The wavelength of nuclear recoil and γ-ray signals are also different. The study of n/γ separation shows that the rejection factor can reach an order of 10-7 with signal efficiency more than 80% at an equivalent electron recoil energy of 20 keV or more. Such a property makes CsI(Na) an ideal candidate for dark matter searches.

preprint2011arXiv

The fast light of CsI(Na) crystals

The responds of different common alkali halide crystals to alpha-rays and gamma-rays are tested in our research. It is found that only CsI(Na) crystals have significantly different waveforms between alpha and gamma scintillations, while others have not this phenomena. It is suggested that the fast light of CsI(Na) crystals arises from the recombination of free electrons with self-trapped holes of the host crystal CsI. Self-absorption limits the emission of fast light of CsI(Tl) and NaI(Tl) crystals.

preprint2010arXiv

Architecture of a Silicon Strip Beam Position Monitor

A collaboration between Fermilab and the Institute for High Energy Physics (IHEP), Beijing, has developed a beam position monitor for the IHEP test beam facility. This telescope is based on 5 stations of silicon strip detectors having a pitch of 60 microns. The total active area of each layer of the detector is about 12x10 cm2. Readout of the strips is provided through the use of VA1` ASICs mounted on custom hybrid printed circuit boards and interfaced to Adapter Cards via copper-over-kapton flexible circuits. The Adapter Cards amplify and level-shift the signal for input to the Fermilab CAPTAN data acquisition nodes for data readout and channel configuration. These nodes deliver readout and temperature data from triggered events to an analysis computer over gigabit Ethernet links.