Source author record

X. Xiao

X. Xiao appears in the imported research catalog. Authorship, coauthor and topic links are available while profile ownership is still unclaimed.

ResearcherUnclaimed source record

Catalog footprint

What is connected

11works
9topics
4close collaborators

Actions

Connect this record

Log in to claim

Research graph

See the researcher in context

Open full explorer

Inspect adjacent papers, topics, institutions and collaborators without losing the researcher page.

Building this map preview

BZPEER is loading the nearby papers, people, topics and institutions for this page.

Published work

11 published item(s)

preprint2026arXiv

Fermionic sub-GeV Dark Matter from evaporating Primordial Black Holes at DarkSide-50

We present a search for boosted dark matter from Primordial Black Holes (PBH) evaporation using the DarkSide-50 ionization-signal-only dataset corresponding to the experiment's ($12202\pm180$) ${\rm kg\: d}$ exposure. We focus on evaporation of PBHs with masses in the range [$10^{14},\,10^{16}$] g producing Dirac fermionic dark matter particles with sub-GeV kinetic energy. These relativistic particles, with energies up to hundreds of MeV, can generate detectable signals for masses below $\mathcal{O}(100)$ MeV. The absence of a signal enables setting complementary limits to those derived from cosmological observations and direct detection searches for cosmic ray-boosted dark matter.

preprint2021arXiv

SiPM-matrix readout of two-phase argon detectors using electroluminescence in the visible and near infrared range

Proportional electroluminescence (EL) in noble gases is used in two-phase detectors for dark matter searches to record (in the gas phase) the ionization signal induced by particle scattering in the liquid phase. The "standard" EL mechanism is considered to be due to noble gas excimer emission in the vacuum ultraviolet (VUV). In addition, there are two alternative mechanisms, producing light in the visible and near infrared (NIR) ranges. The first is due to bremsstrahlung of electrons scattered on neutral atoms ("neutral bremsstrahlung", NBrS). The second, responsible for electron avalanche scintillation in the NIR at higher electric fields, is due to transitions between excited atomic states. In this work, we have for the first time demonstrated two alternative techniques of the optical readout of two-phase argon detectors, in the visible and NIR range, using a silicon photomultiplier matrix and electroluminescence due to either neutral bremsstrahlung or avalanche scintillation. The amplitude yield and position resolution were measured for these readout techniques, which allowed to assess the detection threshold for electron and nuclear recoils in two-phase argon detectors for dark matter searches. To the best of our knowledge, this is the first practical application of the NBrS effect in detection science.

preprint2020arXiv

Design and construction of a new detector to measure ultra-low radioactive-isotope contamination of argon

Large liquid argon detectors offer one of the best avenues for the detection of galactic weakly interacting massive particles (WIMPs) via their scattering on atomic nuclei. The liquid argon target allows exquisite discrimination between nuclear and electron recoil signals via pulse-shape discrimination of the scintillation signals. Atmospheric argon (AAr), however, has a naturally occurring radioactive isotope, $^{39}$Ar, a $β$ emitter of cosmogenic origin. For large detectors, the atmospheric $^{39}$Ar activity poses pile-up concerns. The use of argon extracted from underground wells, deprived of $^{39}$Ar, is key to the physics potential of these experiments. The DarkSide-20k dark matter search experiment will operate a dual-phase time projection chamber with 50 tonnes of radio-pure underground argon (UAr), that was shown to be depleted of $^{39}$Ar with respect to AAr by a factor larger than 1400. Assessing the $^{39}$Ar content of the UAr during extraction is crucial for the success of DarkSide-20k, as well as for future experiments of the Global Argon Dark Matter Collaboration (GADMC). This will be carried out by the DArT in ArDM experiment, a small chamber made with extremely radio-pure materials that will be placed at the centre of the ArDM detector, in the Canfranc Underground Laboratory (LSC) in Spain. The ArDM LAr volume acts as an active veto for background radioactivity, mostly $γ$-rays from the ArDM detector materials and the surrounding rock. This article describes the DArT in ArDM project, including the chamber design and construction, and reviews the background required to achieve the expected performance of the detector.

preprint2020arXiv

Effective field theory interactions for liquid argon target in DarkSide-50 experiment

We reanalize data collected with the DarkSide-50 experiment and recently used to set limits on the spin-independent interaction rate of weakly interacting massive particles (WIMPs) on argon nuclei with an effective field theory framework. The dataset corresponds to a total (16660 $\pm$ 270) kg d exposure using a target of low-radioactivity argon extracted from underground sources. We obtain upper limits on the effective couplings of the 12 leading operators in the nonrelativistic systematic expansion. For each effective coupling we set constraints on WIMP-nucleon cross sections, setting upper limits between $2.4 \times 10^{-45} \, \mathrm{cm}^2$ and $2.3 \times 10^{-42} \, \mathrm{cm}^2$ (8.9 $\times 10^{-45} \, \mathrm{cm}^2$ and 6.0 $\times 10^{-42} \, \mathrm{cm}^2$) for WIMPs of mass of 100 $\mathrm{GeV/c^2}$ (1000 $\mathrm{GeV/c^2}$) at 90\% confidence level.

preprint2020arXiv

Superconducting circuit protected by two-Cooper-pair tunneling

We present a protected superconducting qubit based on an effective circuit element that only allows pairs of Cooper pairs to tunnel. These dynamics give rise to a nearly degenerate ground state manifold indexed by the parity of tunneled Cooper pairs. We show that, when the circuit element is shunted by a large capacitance, this manifold can be used as a logical qubit that we expect to be insensitive to multiple relaxation and dephasing mechanisms.

preprint2016arXiv

Vacuum Rabi Splitting in Nanomechanical QED System with Nonlinear Resonator

Considering the intrinsic nonlinearity in a nanomechanical resonator coupled to a charge qubit, vacuum Rabi splitting effect is studied in a nanomechanical QED (qubit-resonator) system. A driven nonlinear Jaynes-Cummings model describes the dynamics of this qubit-resonator system. Using quantum regression theorem and master equation approach, we have calculated the two-time correlation spectrum analytically. In the weak driving limit, these analytical results clarify the influence of the driving strength and nonlinearity parameter on the correlation spectrum. Also, numerical calculations confirm these analytical results.

preprint2015arXiv

Temporal Behavior of Rabi Oscillation in Nanomechanical QED System with a Nonlinear Resonator

In nanomechanical QED system, consisting of a charge qubit and a nonlinear nanomechanical resonator, we study the temporal behavior of Rabi oscillation in the nonlinear Jaynes-Cummings model. Using microscopic master equation approach, we solve time evolution of the density operator describing this model. Also, the probability of excited state of charge qubit is calculated. These analytic calculations show how nonlinearity parameter and decay rates of two different excited states of the qubit-resonator system affect time-oscillating and decaying of Rabi oscillation.

preprint2014arXiv

PandaX: A Liquid Xenon Dark Matter Experiment at CJPL

PandaX is a large upgradable liquid-xenon detector system that can be used for both direct dark-matter detection and $^{136}$Xe double-beta decay search. It is located in the Jinping Deep-Underground Laboratory in Sichuan, China. The detector operates in dual-phase mode, allowing detection of both prompt scintillation, and ionization charge through proportional scintillation. The central time projection chamber will be staged, with the first stage accommodating a target mass of about 120\,kg. In stage II, the target mass will be increased to about 0.5\,ton. In the final stage, the detector can be upgraded to a multi-ton target mass. In this paper a detailed description of the stage-I detector design and performance results established during the commissioning phase is presented.

preprint2013arXiv

Development of the Liquid Level Meters for the PandaX Dark Matter Detector

The two-phase xenon detector is at the frontier of dark matter direct search. This kind of detector uses liquid xenon as the sensitive target and is operated in two-phase (liquid/gas) mode, where the liquid level needs to be monitored and controlled in sub-millimeter precision. In this paper, we present a detailed design and study of two kinds of level meters for the PandaX dark matter detector. The long level meter is used to monitor the overall liquid level while short level meters are used to monitor the inclination of the detector. These level meters are cylindrical capacitors custom-made from two concentric metal tubes. Their capacitance values are read out by a universal transducer interface chip and recorded by the PandaX slow control system. We present the developments that lead to level meters with long-term stability and sub-millimeter precision. Fluctuations (standard deviations) of less than 0.02 mm for the short level meters and less than 0.2 mm for the long level meter were achieved during a few days of test operation.

preprint2012arXiv

Decay process of quantum open system at finite-temperature

Starting from the formal solution to the Heisenberg equation, we revisit an universal model for a quantum open system with a harmonic oscillator linearly coupled to a boson bath. The analysis of the decay process for a Fock state and a coherent state demonstrate that this method is very useful in dealing with the problems in decay process of the open system. For finite temperature, the calculations of the reduced density matrix and the mean excitation number for the open system show that an initial coherent state will evolve into a temperature-dependant coherent state after tracing over the bath variables. Also in short-time limit, a temperature-dependant effective Hamiltonian for the open system characterizes the decay process of the open system.

preprint2012arXiv

Multi-ion Mach-Zehnder interferometer with artificial nonlinear interactions

We show how to implement a Mach-Zehnder interferometry based upon a string of trapped ions with artificial nonlinear interactions. By adiabatically sweeping down/up the coupling strength between two involved internal states of the ions, we could achieve the beam splitting/recombination. Based on current techniques for manipulating trapped ions, we discuss the experimental feasibility of our scheme and analyze some undesired uncertainty under realistic experimental environment.