Source author record

Weitian Chen

Explore this author’s publications, collaborators and research topics. This catalog record has not been claimed by its author.

ResearcherUnclaimed source record

Catalog footprint

Research overview

5works
5topics
4close collaborators

Published work

5 publications

preprint2026arXiv

Dipolar order mapping based on spin-lock magnetic resonance imaging

Purpose: Inhomogeneous magnetization transfer (ihMT) effect reflects dipolar order with a dipolar relaxation time (T1DT_{1D}), specific to motion-restricted macromolecules. We aim to quantify T1DT_{1D} using spin-lock MRI technique. Methods: In the proposed method, we introduce a T1DT_{1D}-specific ratio, denoted as RATIOdoslRATIO_{dosl}. This ratio is derived from the distinct relaxation rate RdoslR_{dosl}, calculated as the difference between dual-frequency relaxation R1ρdualR_{1ρ}^{dual} and single-frequency R1ρsingleR_{1ρ}^{single} relaxation measurements. A novel rotary-echo spin-lock sequence was developed to enable dual-frequency spin-lock acquisition. We established a framework to estimate T1DT_{1D}, as well as the macromolecular pool fraction (MPF) map. The proposed approach was validated via numerical simulations, phantom studies, and demonstrated in vivo in human white matter. Results: Simulations revealed the high sensitivity of RATIOdoslRATIO_{dosl} to T1DT_{1D}, and substantiated the accuracy and robustness of the proposed methods. Phantom experiments demonstrated robust ihMT contrast and confirmed the capability of T1DT_{1D} quantification via RATIOdoslRATIO_{dosl}. In vivo studies supported the clinical viability of this approcah, achieving simultaneous T1DT_{1D} and MPF mapping using only three spin-lock prepared images. Across ten healthy volunteers, the mean white matter T1DT_{1D} ranged from approximately 3.70 to 4.80 ms. Conclustion: We propose a novel method for T1DT_{1D} quantification based on spin-lock MRI. By requiring only three contrast-prepared images, this technique provides a promising pathway for robust, rapid, and simultaneous T1DT_{1D} and MPF quantification with fewer confounds

preprint2022arXiv

Source-free unsupervised domain adaptation for cross-modality abdominal multi-organ segmentation

Domain adaptation is crucial for transferring the knowledge from the source labeled CT dataset to the target unlabeled MR dataset in abdominal multi-organ segmentation. Meanwhile, it is highly desirable to avoid the high annotation cost related to the target dataset and protect the source dataset privacy. Therefore, we propose an effective source-free unsupervised domain adaptation method for cross-modality abdominal multi-organ segmentation without source dataset access. The proposed framework comprises two stages. In the first stage, the feature map statistics-guided model adaptation combined with entropy minimization is developed to help the top segmentation network reliably segment the target images. The pseudo-labels output from the top segmentation network are used to guide the style compensation network to generate source-like images. The pseudo-labels output from the middle segmentation network is used to supervise the learning progress of the desired model (bottom segmentation network). In the second stage, the circular learning and pixel-adaptive mask refinement are used to further improve the desired model performance. With this approach, we achieved satisfactory abdominal multi-organ segmentation performance, outperforming the existing state-of-the-art domain adaptation methods. The proposed approach can be easily extended to situations in which target annotation data exist. With only one labeled MR volume, the performance can be levelled with that of supervised learning. Furthermore, the proposed approach is proven to be effective for source-free unsupervised domain adaptation in reverse direction.

preprint2022arXiv

Unsupervised domain adaptation for cross-modality liver segmentation via joint adversarial learning and self-learning

Liver segmentation on images acquired using computed tomography (CT) and magnetic resonance imaging (MRI) plays an important role in clinical management of liver diseases. Compared to MRI, CT images of liver are more abundant and readily available. However, MRI can provide richer quantitative information of the liver compared to CT. Thus, it is desirable to achieve unsupervised domain adaptation for transferring the learned knowledge from the source domain containing labeled CT images to the target domain containing unlabeled MR images. In this work, we report a novel unsupervised domain adaptation framework for cross-modality liver segmentation via joint adversarial learning and self-learning. We propose joint semantic-aware and shape-entropy-aware adversarial learning with post-situ identification manner to implicitly align the distribution of task-related features extracted from the target domain with those from the source domain. In proposed framework, a network is trained with the above two adversarial losses in an unsupervised manner, and then a mean completer of pseudo-label generation is employed to produce pseudo-labels to train the next network (desired model). Additionally, semantic-aware adversarial learning and two self-learning methods, including pixel-adaptive mask refinement and student-to-partner learning, are proposed to train the desired model. To improve the robustness of the desired model, a low-signal augmentation function is proposed to transform MRI images as the input of the desired model to handle hard samples. Using the public data sets, our experiments demonstrated the proposed unsupervised domain adaptation framework reached four supervised learning methods with a Dice score 0.912 plus or minus 0.037 (mean plus or minus standard deviation).

preprint2016arXiv

Bi-phase age-related brain gray matter magnetic resonance T1rho relaxation time change

Objectives: To investigate normative value and age-related change of brain magnetic resonance T1rho relaxation at 1.5 T. Methods: 20 males (age: 40.7+/-15.5 years, range: 22-68 years) and 22 females (age: 38.5 +/-14.8 years, range: 21-62 years), were scanned at 1.5 Tesla using 3D fluid suppressed turbo spin echo sequence. Regions-of-interests (ROIs) were obtained by atlas-based tissue segmentation and T1rho was calculated by fitting the mean value to monoexponential model. Correlation between T1rho relaxation of brain gray matter regions and age was investigated. Results: A regional difference among individual gray matter areas was noted; with hippocampus (98.37+/-5.37 msec) and amygdala (94.95+/-4.34 msec) have the highest measurement, while pallidum (83.81+/-5.49) and putamen (83.93+4.76) the lowest measurement. T1rho values decreased slowly (mean slope: -0.256) and significantly (p<0.05) with age in gray matter for subjects younger than 40 years old, while for subjects older than 40 years old there was no significant correlation between T1rho relaxation and age. Conclusion: T1rho relaxation demonstrates a bi-phase change with age in adults of 22-68 years.

preprint2016arXiv

Improved liver T1rho measurement precision with a breathhold black blood single shot fast spin echo acquisition: a validation study in healthy volunteers

Purpose: To explore the usability and normal T1rho value of liver parenchyma with a novel single breathhold black blood single shot fast spin echo acquisition based liver imaging sequence. Materials and Methods: In total 19 health subjects (10 males, 9 females; mean age: 37.4 yrs; range: 23-54 yrs) participated in the study. 11 subjects had liver scanned twice in the same session to access scan-rescan repeatability. 12 subjects had liver scanned twice in two sessions with 7-10 days' interval to access scan-rescan reproducibility. MR was performed with a 3.0 T scanner with dual transmitter. The MR sequence allows simultaneous acquisition of 4 spin lock times (TSLs: 0ms, 10 ms, 30 ms, 50ms) in 10 second. Inherent black blood effect of fast spin echo and double inversion recovery were utilized to achieve blood signal suppression. Results: The technique demonstrated good image quality and minimal artifacts. For liver parenchyma, Bland-Altman plot showed the scan-rescan repeatability mean difference was 0.025 ms (95% limits of agreement: -1.163 to 1.213 ms), and intraclass correlation coefficient (ICC) was 0.977. The scan-rescan reproducibility mean difference was -0.075 ms (95% limits of agreement: -3.280 to 3.310 ms), and ICC was 0.820 which is better than the ICC of 0.764 of a previous bright blood multi-breath hold gradient echo acquisition technique. The liver T1rho value was 39.9 +/- 2.4 ms (range: 36.1 - 44.2 ms), which is lower than the value of 42.8=/-2.1 ms acquired with the previous bright blood technique. Conclusion: This study validated the application of a single breathhold black blood single shot fast spin echo acquisition based for human liver T1rho imaging. The lower liver parenchyma T1rho value and higher scan rescan reproducibility may improve of the sensitivity of this technique.

Research graph

See the researcher in context

Open full explorer

Inspect adjacent papers, topics, institutions and collaborators without losing the researcher page.

Building this map preview

BZPEER is loading the nearby papers, people, topics and institutions for this page.