Source author record

W. Lauth

W. Lauth appears in the imported research catalog. Authorship, coauthor and topic links are available while profile ownership is still unclaimed.

ResearcherUnclaimed source record

Catalog footprint

What is connected

11works
3topics
4close collaborators

Actions

Connect this record

Log in to claim

Research graph

See the researcher in context

Open full explorer

Inspect adjacent papers, topics, institutions and collaborators without losing the researcher page.

Building this map preview

BZPEER is loading the nearby papers, people, topics and institutions for this page.

Published work

11 published item(s)

preprint2022arXiv

Design study for a 500 MeV positron beam at the Mainz Microtron MAMI

A design study has been performed for a positron beam with an energy of 500 MeV to be realized at the applied physics area of the Mainz Microtron MAMI. Positrons will be created after pair conversion of bremsstrahlung, produced by the 855 MeV electron beam af MAMI in a tungsten converter target. From the two conceivable geometries (i) pair conversion in the bremsstrahlung converter target itself, and (ii) bremsstrahlung pair conversion in a separated lead foil, the former was considered in detail. Positrons will be energy selected within an outside open electron beam-line bending magnet, and bent back by an additional sector magnet. Magnetic focusing elements in between are designed to prepare in a well shielded positron target chamber about 6 m away from the target a beam with horizontal and vertical emittances of epsilon_v = 0.055 pi mm mrad (1 sigma), and epsilon_h = 0.12 pi mm mrad (1 sigma), respectively, for a 10 micro m thick amorphous tungsten target and negligible momentum spread. At an accepted positron band width of 1 MeV, spots are expected vertically with an angular spread of 0.064 mrad and a size of 5.0 mm (FWHM), and horizontally with an angular spread of 0.64 mrad and a size of 7.7 mm (FWHM). The positron yield amounts to 13.1 per second, 1 MeV positron energy band width, and 1 nA electron beam current.

preprint2020arXiv

Channeling experiments at planar diamond and silicon single crystals with electrons from the Mainz Microtron MAMI

Line structures were observed for (110) planar channeling of electrons in a diamond single crystal even at a beam energy of 180 MeV. This observation motivated us to initiate dechanneling length measurements as function of the beam energy since the occupation of quantum states in the channeling potential is expected to enhance the dechanneling length. High energy loss signals, generated as a result of emission of a bremsstrahlung photon with about half the beam energy at channeling of 450 and 855 MeV electrons, were measured as function of the crystal thickness. The analysis required additional assumptions which were extracted from the numerical solution of the Fokker-Planck equation. Preliminary results for diamond are presented. In addition, we reanalyzed dechanneling length measurements at silicon single crystals performed previously at the Mainz Microtron MAMI at beam energies between 195 and 855 MeV from which we conclude that the quality of our experimental data set is not sufficient to derive definite conclusions on the dechanneling length. Our experimental results are below the predictions of the Fokker-Planck equation and somewhat above the results of simulation calculations of A. V. Korol and A. V. Solov'yov et al. on the basis of the MBN Explorer simulation package. We somehow conservatively conclude that the prediction of the asymptotic dechanneling length on the basis of the Fokker-Planck equation represents an upper limit.

preprint2020arXiv

Innovative remotely-controlled bending device for thin silicon and germanium crystals

Steering of negatively charged particle beams below 1 GeV has demonstrated to be possible with thin bent silicon and germanium crystals. A newly designed mechanical holder was used for bending crystals, since it allows a remotely-controlled adjustment of crystal bending and compensation of unwanted torsion. Bent crystals were installed and tested at the MAMI Mainz MIcrotron to achieve steering of 0.855-GeV electrons at different bending radii. We report the description and characterization of the innovative bending device developed at INFN Laboratori Nazionali di Legnaro (LNL).

preprint2020arXiv

Time performance of a triple-GEM detector at high rate

Gaseous detectors are used in high energy physics as trackers or, more generally, as devices for the measurement of the particle position. For this reason, they must provide high spatial resolution and they have to be able to operate in regions of intense radiation, i.e. around the interaction point of collider machines. Among these, Micro Pattern Gaseous Detectors (MPGD) are the latest frontier and allow to overcome many limitations of the pre-existing detectors, such as the radiation tolerance and the rate capability. The gas Electron Multiplier (GEM) is a MPGD that exploits an intense electric field in a reduced amplification region in order to prevent discharges. Several amplification stages, like in a triple-GEM, allow to increase the detector gain and to reduce the discharge probability. Reconstruction techniques such as charge centroid (CC) and micro-Time Projection Chamber ($\upmu$TPC) are used to perform the position measurement. From literature triple-GEMs show a stable behaviour up to $10^8\,$Hz/cm$^2$. A testbeam with four planar triple-GEMs has been performed at the Mainz Microtron (MAMI) facility and their performance was evaluated in different beam conditions. In this article a focus on the time performance for the $\upmu$TPC clusterization is given and a new measurement of the triple-GEM limits at high rate will be presented.

preprint2019arXiv

Broad angular anisotropy of multiple scattering in a Si crystal

We observed reduction of multiple Coulomb scattering of 855 MeV electrons within a Si crystalline plate w.r.t. an amorphous plate with the same mass thickness. The reduction owed to complete or partial suppression of the coherent part of multiple scattering in a crystal vs crystal orientation with the beam. Experimental data were collected at Mainz Mikrotron and critically compared to theoretical predictions and Monte Carlo simulations. Our results highlighted maximal 7 % reduction of the r.m.s. scattering angle at certain beam alignment with the [100] crystal axes. However, partial reduction was recorded over a wide range of alignment of the electron beam with the crystal up to 15 deg. This evidence may be relevant to refine the modelling of multiple scattering in crystals for currently used software, which is interesting for detectors in nuclear, medical, high energy physics.

preprint2019arXiv

Technical Design Report for the PANDA Endcap Disc DIRC

PANDA (anti-Proton ANnihiliation at DArmstadt) is planned to be one of the four main experiments at the future international accelerator complex FAIR (Facility for Antiproton and Ion Research) in Darmstadt, Germany. It is going to address fundamental questions of hadron physics and quantum chromodynamics using cooled antiproton beams with a high intensity and and momenta between 1.5 and 15 GeV/c. PANDA is designed to reach a maximum luminosity of 2x10^32 cm^2 s. Most of the physics programs require an excellent particle identification (PID). The PID of hadronic states at the forward endcap of the target spectrometer will be done by a fast and compact Cherenkov detector that uses the detection of internally reflected Cherenkov light (DIRC) principle. It is designed to cover the polar angle range from 5° to 22° and to provide a separation power for the separation of charged pions and kaons up to 3 standard deviations (s.d.) for particle momenta up to 4 GeV/c in order to cover the important particle phase space. This document describes the technical design and the expected performance of the novel PANDA Disc DIRC detector that has not been used in any other high energy physics experiment (HEP) before. The performance has been studied with Monte-Carlo simulations and various beam tests at DESY and CERN. The final design meets all PANDA requirements and guarantees suffcient safety margins.

preprint2016arXiv

Experimental access to Transition Distribution Amplitudes with the PANDA experiment at FAIR

Baryon-to-meson Transition Distribution Amplitudes (TDAs) encoding valuable new information on hadron structure appear as building blocks in the collinear factorized description for several types of hard exclusive reactions. In this paper, we address the possibility of accessing nucleon-to-pion ($πN$) TDAs from $\bar{p}p \to e^+e^- π^0$ reaction with the future PANDA detector at the FAIR facility. At high center of mass energy and high invariant mass squared of the lepton pair $q^2$, the amplitude of the signal channel $\bar{p}p \to e^+e^- π^0$ admits a QCD factorized description in terms of $πN$ TDAs and nucleon Distribution Amplitudes (DAs) in the forward and backward kinematic regimes. Assuming the validity of this factorized description, we perform feasibility studies for measuring $\bar{p}p \to e^+e^- π^0$ with the PANDA detector. Detailed simulations on signal reconstruction efficiency as well as on rejection of the most severe background channel, i.e. $\bar{p}p \to π^+π^- π^0$ were performed for the center of mass energy squared $s = 5$ GeV$^2$ and $s = 10$ GeV$^2$, in the kinematic regions $3.0 < q^2 < 4.3$ GeV$^2$ and $5 < q^2 < 9$ GeV$^2$, respectively, with a neutral pion scattered in the forward or backward cone $| \cosθ_{π^0}| > 0.5 $ in the proton-antiproton center of mass frame. Results of the simulation show that the particle identification capabilities of the PANDA detector will allow to achieve a background rejection factor of $5\cdot 10^7$ ($1\cdot 10^7$) at low (high) $q^2$ for $s=5$ GeV$^2$, and of $1\cdot 10^8$ ($6\cdot 10^6$) at low (high) $q^2$ for $s=10$ GeV$^2$, while keeping the signal reconstruction efficiency at around $40\%$. At both energies, a clean lepton signal can be reconstructed with the expected statistics corresponding to $2$ fb$^{-1}$ of integrated luminosity. (.../...)

preprint2016arXiv

Feasibility studies of time-like proton electromagnetic form factors at PANDA at FAIR

Simulation results for future measurements of electromagnetic proton form factors at \PANDA (FAIR) within the PandaRoot software framework are reported. The statistical precision with which the proton form factors can be determined is estimated. The signal channel $\bar p p \to e^+ e^-$ is studied on the basis of two different but consistent procedures. The suppression of the main background channel, $\textit{i.e.}$ $\bar p p \to π^+ π^-$, is studied. Furthermore, the background versus signal efficiency, statistical and systematical uncertainties on the extracted proton form factors are evaluated using two different procedures. The results are consistent with those of a previous simulation study using an older, simplified framework. However, a slightly better precision is achieved in the PandaRoot study in a large range of momentum transfer, assuming the nominal beam conditions and detector performance.

preprint2012arXiv

Technical Design Report for the: PANDA Micro Vertex Detector

This document illustrates the technical layout and the expected performance of the Micro Vertex Detector (MVD) of the PANDA experiment. The MVD will detect charged particles as close as possible to the interaction zone. Design criteria and the optimisation process as well as the technical solutions chosen are discussed and the results of this process are subjected to extensive Monte Carlo physics studies. The route towards realisation of the detector is outlined.

preprint2012arXiv

Technical Design Report for the: PANDA Straw Tube Tracker

This document describes the technical layout and the expected performance of the Straw Tube Tracker (STT), the main tracking detector of the PANDA target spectrometer. The STT encloses a Micro-Vertex-Detector (MVD) for the inner tracking and is followed in beam direction by a set of GEM-stations. The tasks of the STT are the measurement of the particle momentum from the reconstructed trajectory and the measurement of the specific energy-loss for a particle identification. Dedicated simulations with full analysis studies of certain proton-antiproton reactions, identified as being benchmark tests for the whole PANDA scientific program, have been performed to test the STT layout and performance. The results are presented, and the time lines to construct the STT are described.

preprint2006arXiv

Design considerations for table-top, laser-based VUV and X-ray free electron lasers

A recent breakthrough in laser-plasma accelerators, based upon ultrashort high-intensity lasers, demonstrated the generation of quasi-monoenergetic GeV-electrons. With future Petawatt lasers ultra-high beam currents of ~100 kA in ~10 fs can be expected, allowing for drastic reduction in the undulator length of free-electron-lasers (FELs). We present a discussion of the key aspects of a table-top FEL design, including energy loss and chirps induced by space-charge and wakefields. These effects become important for an optimized table-top FEL operation. A first proof-of-principle VUV case is considered as well as a table-top X-ray-FEL which may open a brilliant light source also for new ways in clinical diagnostics.