Researcher profile

W. Jellema

W. Jellema contributes to research discovery and scholarly infrastructure.

ResearcherAffiliation not importedOpen to collaborate

Trust snapshot

Quick read

Trust 21 - EmergingVerification L1Unclaimed author
6works
0followers
1topics
4close collaborators

Actions

Decide how to stay connected

Follow researcher0

Identity and collaboration

How to connect with this researcher

Claiming links this public author record to a researcher profile and unlocks direct collaboration workflows.

Log in to claim

Direct collaboration

Open a focused conversation when the fit is right

Claim this author entity first to unlock direct invitations.

Research graph

See the researcher in context

Open full explorer

Inspect adjacent work, topics, institutions and collaborators without jumping out to a separate graph page.

Building this graph slice

BZPEER is loading the nearby papers, people, topics and institutions for this page.

Published work

6 published item(s)

preprint2022arXiv

Demonstration of an imaging technique for the measurement of PSF elongation caused by Atmospheric Dispersion

Elongation of the point spread function due to atmospheric dispersion becomes a severe problem for high resolution imaging instruments, if an atmospheric dispersion corrector is not present. In this work we report on a novel technique to measure this elongation, corrected or uncorrected, from imaging data. By employing a simple diffraction mask it is possible to magnify the chromatic elongation caused by the atmosphere and thus make it easier to measure. We discuss the theory and design of such a mask and report on two proof of concept observations using the 40 cm Gratama telescope at the University of Groningen. We evaluate the acquired images using a geometric approach, a forward modelling approach and from a direct measurement of the length of the point spread function. For the first two methods we report measurements consistent with atmospheric dispersion models to within 0.5 arcsec. Direct measurements of the elongation do not prove suitable for the characterisation of atmospheric dispersion. We conclude that the addition of this type of diffraction mask can be valuable for measurements of PSF elongation. This can enable high precision correction of atmospheric dispersion on future instruments.

preprint2022arXiv

Modal Simulation Framework for the Design and Verification of Future Few-Mode Far-Infrared Spectrometers

Future far-infrared space missions require highly-sensitive spectroscopy as a primary diagnostics tool. However, these systems are sensitive to straylight, due to the ultra-sensitive few-mode detectors used, which affects the measurement and calibration of the spectrum, as revealed by the Herschel mission. To ensure that the science goals of future missions are met, the complex modal behaviour has to be understood, and appropriate verification and calibration strategies must be developed. We propose a modal framework to addresses these issues, using Herschel-SPIRE as a case study, and demonstrate how the technique can be used for the design and verification of spectrometers in future far-infrared missions.

preprint2022arXiv

Modelling the Partially Coherent Behaviour of Few-Mode Far-Infrared Grating Spectrometers

Modelling ultra-low-noise far-infrared grating spectrometers has become crucial for the next generation of far-infrared space observatories. Conventional techniques are awkward to apply because of the partially coherent form of the incident spectral field, and the few-mode response of the optics and detectors. We present a modal technique for modelling the behaviour of spectrometers, which allows for the propagation and detection of partially coherent fields, and the inclusion of straylight radiated by warm internal surfaces. We illustrate the technique by modelling the behaviour of the Long Wavelength Band of the proposed SAFARI instrument on the well-studied SPICA mission.

preprint2022arXiv

The MICADO Atmospheric Dispersion Corrector: Optomechanical design, expected performance and calibration techniques

The differential refraction of light passing through the atmosphere can have a severe impact on image quality if no atmospheric dispersion corrector (ADC) is used. For the Extremely Large Telescope (ELT) this holds true well into the infrared. MICADO, the near-infrared imaging camera for the ELT, will employ a cryogenic ADC consisting of two counter-rotating Amici prisms with diameters of 125 mm. The mechanism will reduce the atmospheric dispersion to below 2.5 milli arcseconds (mas), with a set goal of 1 mas. In this report, we provide an overview of the current status of the ADC in development for MICADO. We summarise the optomechanical design and discuss how the cryogenic environment impacts the performance. We will also discuss our plan to use a diffraction mask in the cold pupil to calibrate and validate the performance once the instrument is fully integrated.

preprint2020arXiv

Complex beam mapping and Fourier optics analysis of a wide field Microwave Kinetic Inductance Detector camera

For astronomical instruments, accurate knowledge of the optical pointing and coupling are essential to characterize the alignment and performance of (sub-)systems prior to integration and deployment. Ideally, this requires the phase response of the optical system, which for direct (phase insensitive) detectors was not previously accessible. Here we show development of the phase sensitive complex beam pattern technique using a dual optical source heterodyne technique for a large field of view Microwave Kinetic Inductance Detector camera at 350 GHz. We show here how you can analyze the measured data with Fourier optics, which allows integration into a telescope model to calculate the on sky beam pattern and telescope aperture efficiency prior to deployment at a telescope.

preprint2020arXiv

Quantification of the expected residual dispersion of the MICADO Near-IR imaging instrument

MICADO, a near-infrared imager for the Extremely Large Telescope, is being designed to deliver diffraction limited imaging and 50 micro arcsecond ($μ$as) astrometric accuracy. MICADO employs an atmospheric dispersion corrector (ADC) to keep the chromatic elongation of the point spread function (PSF) under control. We must understand the dispersion and residuals after correction to reach the optimum performance. Therefore, we identified several sources of chromatic dispersion that need to be considered for the MICADO ADC. First, we compared common models of atmospheric dispersion to investigate whether these models remain suitable for MICADO. We showed that the differential dispersion between common atmospheric models and integration over the full atmosphere is less than 10 $μ$as for most observations in H-band. We then performed an error propagation analysis to understand the uncertainty in the atmospheric dispersion as a function of atmospheric conditions. In addition, we investigated the impact of photometric color on the astrometric performance. While the differential refraction between stars within the same field of view can be significant, the inclusion of an ADC rendered this effect negligible. For MICADO specifically, we found that the current optomechanical design dominates the residual dispersion budget of 0.4 milli arcseconds (mas), with a contribution of 0.31 mas due to the positioning accuracy of the prisms and up to 0.15 mas due to a mismatch between the dispersive properties of the glass and the atmosphere. We found no showstoppers in the design of the MICADO ADC for achieving 50 $μ$as relative astrometric accuracy.