Researcher profile

W. Hartung

W. Hartung contributes to research discovery and scholarly infrastructure.

ResearcherAffiliation not importedOpen to collaborate

Trust snapshot

Quick read

Trust 21 - EmergingVerification L1Unclaimed author
7works
0followers
1topics
4close collaborators

Actions

Decide how to stay connected

Follow researcher0

Identity and collaboration

How to connect with this researcher

Claiming links this public author record to a researcher profile and unlocks direct collaboration workflows.

Log in to claim

Direct collaboration

Open a focused conversation when the fit is right

Claim this author entity first to unlock direct invitations.

Research graph

See the researcher in context

Open full explorer

Inspect adjacent work, topics, institutions and collaborators without jumping out to a separate graph page.

Building this graph slice

BZPEER is loading the nearby papers, people, topics and institutions for this page.

Published work

7 published item(s)

preprint2015arXiv

Measurement of Electron Trapping in the CESR Storage Ring

The buildup of low-energy electrons has been shown to affect the performance of a wide variety of particle accelerators. Of particular concern is the persistence of the cloud between beam bunch passages, which can impose limitations on the stability of operation at high beam current. We have obtained measurements of long-lived electron clouds trapped in the field of a quadrupole magnet in a positron storage ring, with lifetimes much longer than the revolution period. Based on modeling, we estimate that about 7% of the electrons in the cloud generated by a 20-bunch train of 5.3 GeV positrons with 16-ns spacing and $1.3x10^{11}$ population survive longer than 2.3 $μ$s in a quadrupole field of gradient 7.4 T/m. We have observed a non-monotonic dependence of the trapping effect on the bunch spacing. The effect of a witness bunch on the measured signal provides direct evidence for the existence of trapped electrons. The witness bunch is also observed to clear the cloud, demonstrating its effectiveness as a mitigation technique.

preprint2014arXiv

Comparison of Electron Cloud Mitigating Coatings Using Retarding Field Analyzers

In 2008, the Cornell Electron Storage Ring (CESR) was reconfigured to serve as a test accelerator (CESR-TA) for next generation lepton colliders, in particular for the ILC damping ring. A significant part of this program has been the installation of diagnostic devices to measure and quantify the electron cloud effect, a potential limiting factor in these machines. One such device is the Retarding Field Analyzer (RFA), which provides information on the local electron cloud density and energy distribution. Several different styles of RFAs have been designed, tested, and deployed throughout the CESR ring. They have been used to study the growth of the cloud in different beam conditions, and to evaluate the efficacy of different mitigation techniques. This paper will provide an overview of RFA results obtained in a magnetic field free environment.

preprint2014arXiv

Measurement and Compensation of Horizontal Crabbing at the Cornell Electron Storage Ring Test Accelerator

In storage rings, horizontal dispersion in the rf cavities introduces horizontal-longitudinal (xz) coupling, contributing to beam tilt in the xz plane. This coupling can be characterized by a "crabbing" dispersion term ζa that appears in the normal mode decomposition of the 1-turn transfer matrix. ζa is proportional to the rf cavity voltage and the horizontal dispersion in the cavity. We report experiments at the Cornell Electron Storage Ring Test Accelerator (CesrTA) where xz coupling was explored using three lattices with distinct crabbing properties. We characterize the xz coupling for each case by measuring the horizontal projection of the beam with a beam size monitor. The three lattice configurations correspond to a) 16 mrad xz tilt at the beam size monitor source point, b) compensation of the ζa introduced by one of two pairs of RF cavities with the second, and c) zero dispersion in RF cavities, eliminating ζa entirely. Additionally, intrabeam scattering (IBS) is evident in our measurements of beam size vs. rf voltage.

preprint2014arXiv

Measurement and Modeling of Electron Cloud in a Field Free Environment Using Retarding Field Analyzers

As part of the CESR-TA program at Cornell, diagnostic devices to measure and quantify the electron cloud effect have been installed throughout the CESR ring. One such device is the Retarding Field Analyzer (RFA), which provides information on the local electron cloud density and energy distribution. In a magnetic field free environment, RFA measurements can be directly compared with simulation to study the growth and dynamics of the cloud on a quantitative level. In particular, the photoemission and secondary emission characteristics of the instrumented chambers can be determined simultaneously.

preprint2014arXiv

Measurements of Electron Cloud Growth and Mitigation in Dipole, Quadrupole, and Wiggler Magnets

Retarding field analyzers (RFAs), which provide a localized measurement of the electron cloud, have been installed throughout the Cornell Electron Storage Ring (CESR), in different magnetic field environments. This paper describes the RFA designs developed for dipole, quadrupole, and wiggler field regions, and provides an overview of measurements made in each environment. The effectiveness of electron cloud mitigations, including coatings, grooves, and clearing electrodes, are assessed with the RFA measurements.

preprint2013arXiv

Intrabeam Scattering Studies at CesrTA

Intrabeam scattering (IBS) limits the emittance and single-bunch current that can be achieved in electron or positron storage ring colliders, damping rings, and light sources. Much theoretical work on IBS exists, and while the theories have been validated in hadron and ion machines, the presence of strong damping makes IBS in lepton machines a different phenomenon. We present the results of measurements at CesrTA of IBS dominated beams, and compare the data with theory. The beams we study have parameters typical of those specified for the next generation of wiggler dominated storage rings: low emittance, small bunch length, and few GeV energy. Our measurements are in good agreement with IBS theory, provided a tail-cut procedure is applied.

preprint2013arXiv

Secondary Electron Yield Measurements of Fermilab's Main Injector Vacuum Vessel

We discuss the progress made on a new installation in Fermilab's Main Injector that will help investigate the electron cloud phenomenon by making direct measurements of the secondary electron yield (SEY) of samples irradiated in the accelerator. In the Project X upgrade the Main Injector will have its beam intensity increased by a factor of three compared to current operations. This may result in the beam being subject to instabilities from the electron cloud. Measured SEY values can be used to further constrain simulations and aid our extrapolation to Project X intensities. The SEY test-stand, developed in conjunction with Cornell and SLAC, is capable of measuring the SEY from samples using an incident electron beam when the samples are biased at different voltages. We present the design and manufacture of the test-stand and the results of initial laboratory tests on samples prior to installation.