Researcher profile

Vivek Muthurangu

Vivek Muthurangu contributes to research discovery and scholarly infrastructure.

ResearcherAffiliation not importedOpen to collaborate

Trust snapshot

Quick read

Trust 15 - UnverifiedVerification L1Unclaimed author
3works
0followers
4topics
4close collaborators

Actions

Decide how to stay connected

Follow researcher0

Identity and collaboration

How to connect with this researcher

Claiming links this public author record to a researcher profile and unlocks direct collaboration workflows.

Log in to claim

Direct collaboration

Open a focused conversation when the fit is right

Claim this author entity first to unlock direct invitations.

Research graph

See the researcher in context

Open full explorer

Inspect adjacent work, topics, institutions and collaborators without jumping out to a separate graph page.

Building this graph slice

BZPEER is loading the nearby papers, people, topics and institutions for this page.

Published work

3 published item(s)

preprint2022arXiv

Automatic Segmentation of the Great Arteries for Computational Hemodynamic Assessment

Background: Computational fluid dynamics (CFD) is increasingly used to assess blood flow conditions in patients with congenital heart disease (CHD). This requires patient-specific anatomy, usually obtained from segmented 3D cardiovascular magnetic resonance (CMR) images. However, segmentation is time-consuming and needs expert input. This study aims to develop and validate a machine learning (ML) method for segmentation of the aorta and pulmonary arteries (PAs) for CFD studies. Methods: 90 CHD patients were retrospectively selected for this study. 3D CMR images were manually segmented to obtain ground-truth (GT) background, aorta and PA labels. These were used to train and optimize a U-Net model. Segmentation performance was primarily evaluated using Dice score. CFD simulations were set up from GT and ML segmentations using a semi-automatic meshing and simulation pipeline. Pressure and velocity fields were computed, and a mean average percentage error (MAPE) was calculated for each vessel pair. A secondary observer (SO) segmented the test dataset to assess inter-observer variability. Friedman tests were used to compare segmentation metrics and flow field errors. Results: The model's Dice score (ML vs GT) was 0.945 for the aorta and 0.885 for the PAs. Differences with the inter-observer Dice score (SO vs GT) and ML vs SO Dice scores were not statistically significant for either aorta or PAs. The ML vs GT MAPEs for pressure and velocity in the aorta were 10.1% and 4.1% respectively, and for the PAs 14.6% and 6.3%, respectively. Inter-observer (SO vs GT) and ML vs SO pressure and velocity MAPEs were of a similar magnitude to ML vs GT. Conclusions: The proposed method can successfully segment the great vessels for CFD, with errors similar to inter-observer variability. This reduces the time and effort needed for CFD analysis, making it more attractive for routine clinical use.

preprint2020arXiv

Memory reduced non-Cartesian MRI encoding using the mixed-radix tensor product on CPU and GPU

Multi-dimensional non-Cartesian MRI encoding using the precomputed interpolator can encounter the curse of dimensionality, in which the interpolator size exceeds the available memory on the parallel accelerators. Here we reformulate the multi-dimensional non-uniform fast Fourier transform (NUFFT) to a tensor form. The exponentially growing size of the fully precomputed interpolator can be reduced by tensor analysis. We propose a tree-like, mixed-radix tensor method which flexibly reduces the storage of the NUFFT. A parallel tensor product algorithm is proposed and tested with in vivo cardiac MRI data. Cross-architecture comparisons show that up to 88.1% and 62.4% memory savings are seen in 3D and 2D CINE MRI, respectively, subject only to a negligible loss of accuracy compared to the double-precision CPU version.

preprint2018arXiv

Real-time Cardiovascular MR with Spatio-temporal Artifact Suppression using Deep Learning - Proof of Concept in Congenital Heart Disease

PURPOSE: Real-time assessment of ventricular volumes requires high acceleration factors. Residual convolutional neural networks (CNN) have shown potential for removing artifacts caused by data undersampling. In this study we investigated the effect of different radial sampling patterns on the accuracy of a CNN. We also acquired actual real-time undersampled radial data in patients with congenital heart disease (CHD), and compare CNN reconstruction to Compressed Sensing (CS). METHODS: A 3D (2D plus time) CNN architecture was developed, and trained using 2276 gold-standard paired 3D data sets, with 14x radial undersampling. Four sampling schemes were tested, using 169 previously unseen 3D 'synthetic' test data sets. Actual real-time tiny Golden Angle (tGA) radial SSFP data was acquired in 10 new patients (122 3D data sets), and reconstructed using the 3D CNN as well as a CS algorithm; GRASP. RESULTS: Sampling pattern was shown to be important for image quality, and accurate visualisation of cardiac structures. For actual real-time data, overall reconstruction time with CNN (including creation of aliased images) was shown to be more than 5x faster than GRASP. Additionally, CNN image quality and accuracy of biventricular volumes was observed to be superior to GRASP for the same raw data. CONCLUSION: This paper has demonstrated the potential for the use of a 3D CNN for deep de-aliasing of real-time radial data, within the clinical setting. Clinical measures of ventricular volumes using real-time data with CNN reconstruction are not statistically significantly different from the gold-standard, cardiac gated, BH techniques.