Source author record

Venkataramana Ajjarapu

Venkataramana Ajjarapu appears in the imported research catalog. Authorship, coauthor and topic links are available while profile ownership is still unclaimed.

ResearcherUnclaimed source record

Catalog footprint

What is connected

4works
5topics
3close collaborators

Actions

Connect this record

Log in to claim

Research graph

See the researcher in context

Open full explorer

Inspect adjacent papers, topics, institutions and collaborators without losing the researcher page.

Building this map preview

BZPEER is loading the nearby papers, people, topics and institutions for this page.

Published work

4 published item(s)

preprint2022arXiv

Deriving DERs VAR-Capability Curve at TSO-DSO Interface to Provide Grid Services

The multitudes of inverter-based distributed energy resources (DERs) can be envisioned as distributed reactive power (var) devices (\textit{mini-SVCs}) that can offer var flexibility at TSO-DSO interface. To facilitate this vision, a systematic methodology is proposed to derive an aggregated var capability curve of a distribution system with DERs at the substation level, analogous to a conventional bulk generator. Since such capability curve will be contingent to the operating conditions and network constraints, an optimal power flow (OPF) based approach is proposed that takes inverter headroom flexibility, unbalanced nature of system and coupling with grid side voltage into account along with changing operating conditions. Further, the influence of several factors such as compliance to IEEE 1547 on the capability curve is thoroughly investigated on an IEEE 37 bus and 123 bus distribution test system along with unbalanced DER proliferation. Validation with nonlinear analysis is presented along with demonstration of a scenario with T-D co-simulation.

preprint2020arXiv

Data-Driven Approach for Uncertainty Propagation and Reachability Analysis in Dynamical Systems

In this paper, we propose a data-driven approach for uncertainty propagation and reachability analysis in a dynamical system. The proposed approach relies on the linear lifting of a nonlinear system using linear Perron-Frobenius (P-F) and Koopman operators. The uncertainty can be characterized in terms of the moments of a probability density function. We demonstrate how the P-F and Koopman operators are used for propagating the moments. Time-series data is used for the finite-dimensional approximation of the linear operators, thereby enabling data-driven approach for moment propagation. Simulation results are presented to demonstrate the effectiveness of the proposed method.

preprint2018arXiv

Monitoring Long Term Voltage Instability due to Distribution & Transmission Interaction using Unbalanced μPMU & PMU Measurements

This paper extends the idea of the Thevenin equivalent into unbalanced 3ϕ circuits and proposes a 3ϕ long-term voltage stability indicator (VSI), that can identify critical loads in a system. Furthermore, in order to identify whether the voltage stability limit is due to the transmission network or a distribution network, a transmission-distribution distinguishing index (TDDI) is proposed. The novelty in the proposed indices is that they can account for the unbalance in the lines and loads, enabling them to use unbalanced phasor measurements naturally. This is supported by mathematical derivations and numerical results. A convex optimization formulation to estimate the 3ϕ Thevenin equivalent using PMU & μPMU measurements is proposed, making it possible to calculate VSI and TDDI in an online model-free manner. Numerical simulations performed using co-simulation between Pypower and GridlabD are presented for the IEEE 9 bus and the 30 bus transmission networks combined with several modified IEEE 13 node and 37 node distribution networks. These case studies validate the proposed 3ϕ-VSI and TDDI over a wide range of scenarios and demonstrate the importance of μPMU measurements in identifying the regions causing long term voltage instability.

preprint2018arXiv

PMU based Monitoring and Mitigation of Delayed Voltage Recovery using Admittances

This paper analyzes the delayed voltage recovery phenomenon by simplifying the Western Electricity Coordinating Council (WECC) composite load model using the load admittance and the thermal relay dynamics. From this analysis, a closed form expression approximating the recovery time is derived and the key load parameters impacting the behavior of voltage recovery are identified. A monitoring scheme based on the measured load admittance is then proposed to detect the onset of stalling, even in the presence of voltage oscillations, and estimate the duration of the delayed voltage recovery. A mitigation scheme utilizing smart thermostats and offline learning is also derived to ensure that the voltage recovers to the pre-contingency voltage within a specified time. Both the monitoring and mitigation schemes only need local measurements at a substation making them promising for online applications. Results for the monitoring and mitigation schemes are described in detail for the IEEE 162 bus system validating the various assumptions used for the analysis and establishing the connection between the delayed voltage recovery phenomenon and load admittance.