Source author record

V. V. Mytrochenko

V. V. Mytrochenko appears in the imported research catalog. Authorship, coauthor and topic links are available while profile ownership is still unclaimed.

ResearcherUnclaimed source record

Catalog footprint

What is connected

11works
4topics
4close collaborators

Actions

Connect this record

Log in to claim

Research graph

See the researcher in context

Open full explorer

Inspect adjacent papers, topics, institutions and collaborators without losing the researcher page.

Building this map preview

BZPEER is loading the nearby papers, people, topics and institutions for this page.

Published work

11 published item(s)

preprint2022arXiv

Magnetic system for cleaning the gamma beam at the LUE-40 electron linac output

The bremsstrahlung of accelerated electrons passing through a converter is used to study multiparticle photo-nuclear reactions. The results of calculations, numerical modeling, design, and testing of a special magnetic cleaning system to obtain a "pure" beam of bremsstrahlung quanta when studying the cross-sections of such reactions at the LUE-40 linac are presented. The system is based on commercially available permanent magnets of rectangular cross-sections. The maximum on-axis field is 0.9 T, which provides sufficient separation of the electron beam and gamma rays at a distance of more than 90 mm from the magnet.

preprint2022arXiv

Photonuclear reactions ${^{65}\rm{Cu}}(γ,n)^{64}\rm{Cu}$ and ${^{63}\rm{Cu}}(γ,xn)^{63-x}\rm{Cu}$ cross-sections in the energy range $E_{\rm{γmax}}$ = 35-94 MeV

The bremsstrahlung flux-averaged cross-sections $\langle{σ(E_{\rm{γmax}})}\rangle$ for the photonuclear reactions ${^{65}\rm{Cu}}(γ,n)^{64}\rm{Cu}$, ${^{63}\rm{Cu}}(γ,n)^{62}\rm{Cu}$, ${^{63}\rm{Cu}}(γ,2n)^{61}\rm{Cu}$ and ${^{63}\rm{Cu}}(γ,3n)^{60}\rm{Cu}$ have been measured in the range of bremsstrahlung end-point energies $E_{\rm{γmax}}$ = 35-94 MeV. The experiments were performed with the electron beam from the NSC KIPT linear accelerator LUE-40 with the use of the activation and off-line $γ$-ray spectrometric technique. The calculation of the flux-average cross-sections $\langle{σ(E_{\rm{γmax}})}\rangle_{\rm{th}}$ was carried out using the cross-section $σ(E)$ values from the TALYS1.95 code with the default options. It is shown that the experimental average cross-sections for the reactions ${^{65}\rm{Cu}}(γ,n)^{64}\rm{Cu}$, ${^{63}\rm{Cu}}(γ,n)^{62}\rm{Cu}$, ${^{63}\rm{Cu}}(γ,2n)^{61}\rm{Cu}$ are systematically higher than the theoretical estimates in the TALYS1.95 code. The obtained $\langle{σ(E_{\rm{γmax}})}\rangle$ supplement the data of different laboratories for the case of reactions $(γ,n)$ and $(γ,2n)$. For the reaction ${^{63}\rm{Cu}}(γ,3n)^{60}\rm{Cu}$, the values of $\langle{σ(E_{\rm{γmax}})}\rangle$ were measured for the first time.

preprint2021arXiv

Cross-sections of photoneutron reactions on $^{181}$Ta at $e_{\rm γmax}$ up to 95 MeV

The total bremsstrahlung flux-averaged cross-sections $\langle{σ(E_{\rm{γmax}})}\rangle$ for the photonuclear reactions $^{181}\rm{Ta}(γ,\textit{x}n; \textit{x} \leq 8)^{181-\textit{x}}\rm{Ta}$ have been measured in the range of end-point energies $E_{\rm γmax}$ up to 95 MeV. The experiments were performed with the beam from the NSC KIPT electron linear accelerator LUE-40 with the use of the activation and off-line $γ$-ray spectrometric technique. The calculation of average cross-sections was carried out using the cross-section values computed with the TALYS1.95 code for different level density models $LD$ 1-6. A comparison between the experimental total cross-sections $\langle{σ(E_{\rm{γmax}})}\rangle$ and the theoretical values has shown satisfactory agreement for the $^{181}\rm{Ta}(γ,\textit{x}n)$ reactions with the escape of 1-4, 6 and 7 neutrons. The closest agreement with the measured data is observed with the $LD$5 computation version, which represents the microscopic level density model taking into account Hilaire's combinatorial tables.

preprint2021arXiv

Isomeric Ratio of the $^{181}\rm{Ta}(γ,3n)^{178m,g}\rm{Ta}$ Reaction Products at Energy $E_{\rm{γmax}}$ up to 95 MeV

The photoneutron reaction $^{181}\rm{Ta}(γ,3n)^{178m,g}\rm{Ta}$ was investigated with the beam from the NSC KIPT electron linear accelerator LUE-40. The measurements were performed using the residual $γ$-activity method. The bremsstrahlung flux-averaged cross-sections $\langle{σ(E_{\rm{γmax}})}\rangle$, $\langle{σ(E_{\rm{γmax}})}\rangle_{\rm{m}}$, $\langle{σ(E_{\rm{γmax}})}\rangle_{\rm{g}}$ and the isomeric ratio of the reaction products $d(E_{\rm{γmax}})$ have been measured. Theoretical values of averaged cross-sections and isomeric ratio were calculated using partial cross-sections from the TALYS1.95 code for different level density models $LD$ 1-6. The obtained experimental $d(E_{\rm{γmax}})$ agree with the literature data, but differ from the theoretical values in absolute magnitude and the behavior of the energy dependence. A comparison of the found averaged cross-sections with the calculated ones showed the best agreement for the case of the $LD$ 5 model.

preprint2016arXiv

Coupling cavity model for circular cylindrical waveguide with uniform cross section

We developed the general approach that gives possibility to calculate the coupling coefficients for arbitrary chain of resonators without using the great number of eigen functions. For understanding this method and having possibility to control the accuracy of obtained results, we applied this procedure for simplest structure that has the analytical solutions - a circular cylindrical waveguide with uniform cross section.

preprint2016arXiv

Numerical design of nonuniform disk-loaded waveguides

On the base of modified mode matching method we obtain some results that can be useful in the process of tuning of nonunifrom disk-loaded structures. Our consideration has shown that there are some parameters that depend only on the geometric sizes of sells and equals known values for the needed phase distribution of the amplitudes of field expansion. Changing the geometric sized in such way that these parameters will tend to a given values, we can numerically design the structure that have the given phase distribution of these amplitudes. We consider these tuning parameters as a good instrument under simulation of inhomogeneous structures with sizes that usually used in accelerators.

preprint2016arXiv

Numerical investigation of tuning method for nonuniform disk-loaded waveguides

On the base of more general model we assessed accuracy of method that is widely used for post- tuning accelerator sections. Our consideration has shown that for wide range of disk loaded waveguide (DLW) parameters using simple tuning coefficients gives appropriate characteristics of DLWs. For injector sections, in which phase velocity and amplitude change, there are some deviation from the desired characteristics. It is necessary to evaluate the influence of additional phase shift on beam characteristics at the injector exit.

preprint2015arXiv

Coupled cavity model based on the mode matching technique

We have developed the mode matching technique that is based on the using the eigenmodes of circular cavities and the eigenwaves of circular waveguides as the basic functions for calculation the properties of nonuniform disc-loaded waveguides. We have obtained exact infinite systems of coupled equations which can be reduced by making some assumptions. Under such procedure we can receive more exact parameters of nonuniform equivalent circuits by solving the appropriative algebraic systems. These parameters of equivalent circuits are functions both geometric sizes and frequency. Moreover, under such approach all used values have interpretation. We called this approach as coupled cavity model.

preprint2015arXiv

Coupled cavity model for disc-loaded waveguides

The coupled cavity model for calculation characteristics of inhomogeneous disc-loaded waveguides with taking into account the rounding of the disk hole edges was developed. On the base of this model simulation of section tuning process with the field measurement method was conducted. Accuracy of this method under tuning of disc-loaded waveguides was evaluated. As it follows from our investigation one can use simple coefficients in tuning process, but the needed values of these coefficients must be obtained by calculation of DLW parameters.

preprint2015arXiv

Electromagnetic fields in nonuniform disk-loaded waveguides

On the base of general approach we obtain some results that can be useful in the process of tuning of nonunifrom disc-loaded waveguides. Our consideration has shown that simple values that characterize the detuning of the cells can be introduced only for the disc-loaded waveguide with parameters that change very slow. In general case it is needed to conduct full numerical simulation of specific disc-loaded waveguide and obtain all necessary coupling coefficients. After that one can start the tuning process on the base of bead-pull field distribution measurements.