Source author record

V. Plokhotnichenko

V. Plokhotnichenko appears in the imported research catalog. Authorship, coauthor and topic links are available while profile ownership is still unclaimed.

ResearcherUnclaimed source record

Catalog footprint

What is connected

4works
1topics
4close collaborators

Actions

Connect this record

Log in to claim

Research graph

See the researcher in context

Open full explorer

Inspect adjacent papers, topics, institutions and collaborators without losing the researcher page.

Building this map preview

BZPEER is loading the nearby papers, people, topics and institutions for this page.

Published work

4 published item(s)

preprint2006arXiv

Search for optical activity of SGR 1806-20

The region of SGR 1806-20 localization was observed during its gamma-ray activity in 2001. The observations have been performed on the 6-meter telescope of the Special Astrophysical Observatory, using the Panoramic Photometer-Polarimeter (PPP). The search for variability was performed on the $10^{-6}$ - 10 s time scale, and its results were compared to the properties of corresponding x-ray flares.

preprint2003arXiv

Position-sensitive detector for the 6-meter optical telescope

The Position-Sensitive Detector (PSD) for photometrical and spectral observation on the 6-meter optical telescope of the Special Astrophysical Observatory (Russia) is described. The PSD consists of a position-sensitive tube, amplifiers of output signals, analog-to-digital converters (ADC) and a digital logic plate, which produces a signal for ADC start and an external strob pulse for reading information by registration system. If necessary, the thermoelectric cooler can be used. The position-sensitive tube has the following main elements: a photocathode, electrodes of inverting optics, a block of microchannel plates (MCP) and a position-sensitive collector of quadrant type. The main parameters of the PSD are the diameter of the sensitive surface is 25 mm, the spatial resolution is better than 100 (μ)m in the centre and a little worse on the periphery; the dead time is near 0.5 (μ)s; the detection quantum efficiency is defined by the photocathode and it is not less than 0.1, as a rule; dark current is about hundreds of cps, or less, when cooling. PSD spectral sensitivity depends on the type of photocathode and input window material. We use a multialkali photocathode and a fiber or UV-glass, which gives the short- wave cut of 360 nm or 250 nm, respectively.

preprint2003arXiv

The Multicolor Panoramic Photometer-Polarimeter with high time resolution based on the PSD

Multicolor Panoramic Photometer-Polarimeter (MPPP) with a time resolution of 1 microsecond has been built based on a PSD and used at the 6-meter telescope in SAO (Russia). The device allows registration of the photon fluxes in four photometric bands simultaneously and finding values of 3 Stokes parameters. MPPP consists of Position-Sensitive Detector (PSD), acquisition MANIA-system, polarization unit and a set of dichroic filters. MPPP gives a possibility of detecting photons in 2 pupils with a size of 10 - 15 arc sec centered on the object and comparison star positions simultaneously. The first half of the object photon flux passes through the phase rotating plate and polarizer, and the second one through the polarizer alone. MPPP registers in each of the 4 filters four images of the object with different orientations of polarization plane and one image of a comparison star. It allows measuring instantaneous Stokes parameters. The main astrophysical problems to be solved with MPPP are as follows: investigation of optical pulsars; study of GRB phenomenon in the optical range; searching for single black holes; study of fast variability of X-ray binaries. As an illustration of MPPP use, the results of observations at the 6-meter telescope of Crab pulsar and soft gamma repeater are presented.