Source author record

V. L. Khandramai

Explore this author’s publications, collaborators and research topics. This catalog record has not been claimed by its author.

ResearcherUnclaimed source record

Catalog footprint

Research overview

2works
1topics
4close collaborators

Published work

2 publications

preprint2013arXiv

The polarized Bjorken sum rule analysis: revised

We present progress in the QCD analysis of the Bjorken sum rule at low momentum transfers. We study asymptotic structure of the perturbative QCD expansion at low Q2Q^2 scales based on analysis of recent accurate data on the Bjorken sum rule and available now four-loop expression for the coefficient-function CBj(Q2)C_{Bj}(Q^2). We demonstrate that the standard perturbative series for CBj(Q2)C_{Bj}(Q^2) gives a hint to its asymptotic nature manifesting itself in the region Q2≲1Q^2 \lesssim 1 GeV2^2. It is confirmed by the considered integral model for the perturbative QCD correction. We extract a value of higher-twist μ4μ_4 coefficient and study the interplay between higher orders and higher-twist contributions. Results of other approaches to the description of Bjorken sum rule data are discussed.

preprint2011arXiv

Four-loop QCD analysis of the Bjorken sum rule vs data

We study the polarized Bjorken sum rule at low momentum transfers in the range 0.22<Q<1.73GeV0.22<Q<1.73 {\rm GeV} with the four-loop N3^3LO expression for the coefficient function CBj(αs)C_{\rm Bj}(α_s) in the framework of the common QCD perturbation theory (PT) and the singularity-free analytic perturbation theory (APT). The analysis of the PT series for CBj(αs)C_{\rm Bj}(α_s) gives a hint to its asymptotic nature manifesting itself in the region Q<1Q<1 GeV. It relates to the observation that the accuracy of both the three- and four-loop PT predictions happens to be at the same 10% level. On the other hand, the usage of the two-loop APT allows one to describe the precise low energy JLab data down to Q∼300Q\sim 300 MeV and gives a possibility for reliable extraction of the higher twist (HT) corrections. At the same time, above Q∼700Q\sim 700 MeV the APT two-loop order with HT is equivalent to the four-loop PT with HT compatible to zero and is adequate to current accuracy of the data.

Research graph

See the researcher in context

Open full explorer

Inspect adjacent papers, topics, institutions and collaborators without losing the researcher page.

Building this map preview

BZPEER is loading the nearby papers, people, topics and institutions for this page.