Researcher profile

U. Mohideen

U. Mohideen contributes to research discovery and scholarly infrastructure.

ResearcherAffiliation not importedOpen to collaborate

Trust snapshot

Quick read

Trust 21 - EmergingVerification L1Unclaimed author
17works
0followers
7topics
4close collaborators

Actions

Decide how to stay connected

Follow researcher0

Identity and collaboration

How to connect with this researcher

Claiming links this public author record to a researcher profile and unlocks direct collaboration workflows.

Log in to claim

Direct collaboration

Open a focused conversation when the fit is right

Claim this author entity first to unlock direct invitations.

Research graph

See the researcher in context

Open full explorer

Inspect adjacent work, topics, institutions and collaborators without jumping out to a separate graph page.

Building this graph slice

BZPEER is loading the nearby papers, people, topics and institutions for this page.

Published work

17 published item(s)

preprint2014arXiv

Investigation of the Casimir interaction between two magnetic metals in comparison with nonmagnetic test bodies

We present the complete results for the dynamic experiment on measuring the gradient of the Casimir force between magnetic (Ni-coated) surfaces of a plate and a sphere. Special attention is paid to the description of some details of the setup, its calibration, error analysis and background effects. Computations are performed in the framework of the Lifshitz theory at nonzero temperature with account of analytic corrections to the proximity force approximation and of surface roughness using both the Drude and the plasma model approaches. The theory of magnetic interaction between a sphere and a plate due to domain structure of their surfaces is developed for both out-of-plane and in-plane magnetizations in the absence and in the presence of spontaneous magnetization. It is shown that in all cases the magnetic contribution to the measured force gradients is much smaller than the total experimental error. The comparison between experiment and theory is done using the rigorous statistical method. It is shown that the theoretical approach taking into account dissipation of free electrons is excluded by the data at a 95% confidence level. The approach neglecting dissipation is confirmed by the data at more than 90% confidence level. We prove that the results of experiments with Ni-Ni, Ni-Au and Au-Au surfaces taken together cannot be reconciled with the approach including free electrons dissipation by the introduction of any unaccounted background force, either attractive or repulsive.

preprint2014arXiv

Theory of the Casimir interaction for graphene-coated substrates using the polarization tensor and comparison with experiment

We propose a theory of the thermal Casimir interaction for multilayered test bodies coated with a graphene sheet. The reflection coefficients on such structures are expressed in terms of the components of the polarization tensor and the dielectric permittivities of material layers. The developed theory is applied to calculate the gradient of the Casimir force between an Au-coated sphere and a graphene sheet deposited on a SiO${}_2$ film covering a Si plate, which is the configuration of a recent experiment performed by means of a dynamic atomic force microscope. The theoretical results are found to be in very good agreement with the experimental data. We thus confirm that graphene influences the Casimir interaction and can be used for tailoring the force magnitude in nanostructures.

preprint2013arXiv

Casimir interaction at liquid nitrogen temperature: Comparison between experiment and theory

We have measured the normalized gradient of the Casimir force between Au-coated surfaces of the sphere and the plate and equivalent Casimir pressure between two parallel Au plates at T=77K. These measurements have been performed by means of dynamic force microscope adapted for operating at low temperatures in the frequency shift technique. It was shown that the measurement results at T=77K are in a very good agreement with those at T=300K and with computations at T=77K using both theoretical approaches to the thermal Casimir force proposed in the literature. No thermal effect in the Casimir pressure was observed in the limit of experimental errors with the increase of temperature from T=77K to T=300K. Taking this into account, we have discussed the possible role of patch potentials in the comparison between measured and calculated Casimir pressures.

preprint2013arXiv

Constraints on corrections to Newtonian gravity from two recent measurements of the Casimir interaction between metallic surfaces

We obtain constraints on parameters of the Yukawa-type corrections to Newton's gravitational law from measurements of the gradient of the Casimir force between surfaces coated with ferromagnetic metal Ni and from measurements of the Casimir force between Au-coated sinusoidally corrugated surfaces at various angles between corrugations. It is shown that constraints following from the experiment with magnetic surfaces are slightly weaker than currently available strongest constraints, but benefit from increased reliability and independence of systematic effects.The constraints derived from the experiment with corrugated surfaces within the interaction region from 11.6 to 29.2\,nm are stronger up to a factor of 4 than the strongest constraints derived from other experiments. The possibility of further strengthening of constraints on non-Newtonian gravity by using the configurations with corrugated boundaries is proposed.

preprint2013arXiv

Demonstration of the Casimir force between ferromagnetic surfaces of a Ni-coated sphere and a Ni-coated plate

We demonstrate the Casimir interaction between two ferromagnetic boundary surfaces using the dynamic atomic force microscope. The experimental data are found to be in excellent agreement with the predictions of the Lifshitz theory for magnetic boundary surfaces combined with the plasma model approach. It is shown that for magnetic materials the role of hypothetical patch potentials is opposite to that required for reconciliation of the data with the Drude model.

preprint2013arXiv

Measuring the Casimir force gradient from graphene on a SiO_2 substrate

The gradient of the Casimir force between a Si-SiO${}_2$-graphene substrate and an Au-coated sphere is measured by means of a dynamic atomic force microscope operated in the frequency shift technique. It is shown that the presence of graphene leads to up to 9% increase in the force gradient at the shortest separation considered. This is in qualitative agreement with the predictions of an additive theory using the Dirac model of graphene.

preprint2012arXiv

Constraints on non-Newtonian gravity and light elementary particles from measurements of the Casimir force by means of dynamic AFM

We derive constraints on corrections to Newtonian gravity of the Yukawa type and light elementary particles from two recently performed measurements of the gradient of the Casimir force. In the first measurement the configuration of two Au surfaces has been used, whereas in the second a nonmagnetic metal Au interacted with a magnetic metal Ni. In these configurations one arrives at different, respectively, similar theoretical predictions for the Casimir force when the competing theoretical approaches are employed. Nevertheless, we demonstrate that the constraints following from both experiments are in mutual agreement and in line with constraints obtained from earlier measurements. This confirms the reliability of constraints on non-Newtonian gravity obtained from measurements of the Casimir force.

preprint2012arXiv

Modifying the Casimir force between indium tin oxide film and Au sphere

We present complete results of the experiment on measuring the Casimir force between an Au-coated sphere and an untreated or, alternatively, UV-treated indium tin oxide film deposited on a quartz substrate. Measurements were performed using an atomic force microscope in a high vacuum chamber. The measurement system was calibrated electrostatically. Special analysis of the systematic deviations is performed, and respective corrections in the calibration parameters are introduced. The corrected parameters are free from anomalies discussed in the literature. The experimental data for the Casimir force from two measurement sets for both untreated and UV-treated samples are presented. The experimental errors are determined at a 95% confidence level. It is demonstrated that the UV treatment of an I TO plate results in a significant decrease in the magnitude of the Casimir force (from 21% to 35% depending on separation). However, ellipsometry measurements of the imaginary parts of dielectric permittivities of the untreated and UV-treated samples did not reveal any significant differences. The experimental data are compared with computations in the framework of the Lifshitz theory. It is found that the data for the untreated sample are in a very good agreement with theoretical results taking into account the free charge carriers in an ITO film. For the UV-treated sample the data exclude the theoretical results obtained with account of free charge carriers. These data are in a very good agreement with computations disregarding the contribution of free carriers. According to the explanation provided, this is caused by the phase transition of the ITO film from metallic to dielectric state caused by the UV treatment. Possible applications of the discovered phenomenon in nanotechnology are discussed.

preprint2011arXiv

Capacitance measurements and electrostatic calibrations in experiments measuring the Casimir force

We compare the results of capacitance measurements in the lens-plane and sphere-plane configurations with theoretical predictions from various models of a spherical surface. It is shown that capacitance measurements are incapable of discriminating between models of perfect and modified spherical surfaces in an experiment demonstrating the anomalous scaling law for the electric force. Claims to the contrary in the recent literature are explained by the use of irregular comparison. The data from capacitance measurements in an experiment measuring the Casimir force using a micromechanical torsional oscillator are shown to be in excellent agreement with theoretical predictions using the model of a perfect spherical surface.

preprint2011arXiv

Control of the Casimir Force Using Semiconductor Test Bodies

We describe experimental and related theoretical work on the measurement of the Casimir force using semiconductor test bodies. This field of research started in 2005 and several important and interesting results have already been obtained. Specifically, the Casimir force or its gradient were measured in the configuration of an Au-coated sphere and different semiconductor surfaces. It was found that the force magnitude depends significantly on the replacement of the metal with a semiconductor and on the concentration of charge carriers in the semiconductor material. Special attention is paid to the experiment on the optical modulation of the Casimir force. In this experiment the difference Casimir force between an Au-coated sphere and Si plate in the presence and in the absence of laser light was measured. Possible applications of this experiment are discussed, specifically, for the realization of the pulsating Casimir force in three-layer systems. Theoretical problems arising from the comparison of the experimental data for the difference Casimir force with the Lifshitz theory are analyzed. We consider the possibility to control the magnitude of the Casimir force in phase transitions of semiconductor materials. Experiments on measuring the Casimir force gradient between an Au-coated sphere and Si plate covered with rectangular corrugations of different character are also described. Here, we discuss the interplay between the material properties and nontrivial geometry and the applicability of the proximity force approximation. The review contains comparison between different experiments and analysis of their advantages and disadvantages.

preprint2011arXiv

Reduction of the Casimir force from indium tin oxide film by UV treatment

A significant decrease in the magnitude of the Casimir force (from 21% to 35%) was observed after an indium tin oxide (ITO) sample interacting with an Au sphere was subjected to the UV treatment. Measurements were performed by using an atomic force microscope (AFM) in high vacuum. The experimental results are compared with theory, and a hypothetical explanation for the observed phenomenon is proposed.

preprint2010arXiv

Lateral Casimir force between sinusoidally corrugated surfaces: Asymmetric profiles, deviations from the proximity force approximation and comparison with exact theory

The lateral Casimir force, which arises between aligned sinusoidally corrugated surfaces of a sphere and a plate, was measured for the case of a small corrugation period beyond the applicability region of the proximity force approximation. The increased amplitudes of the corrugations on both the sphere and the plate allowed observation of an asymmetry of the lateral Casimir force, i.e., deviation of its profile from a perfect sine function. The dependences of the lateral force on the phase shift between the corrugations on both test bodies were measured at different separations in two sets of measurements with different amplitudes of corrugations on the sphere. The maximum magnitude of the lateral force as a function of separation was also measured in two successive experiments. All measurement data were compared with the theoretical approach using the proximity force approximation and with the exact theory based on Rayleigh expansions with no fitting parameters. In both cases real material properties of the test bodies and nonzero temperature were taken into account. The data were found to be in a good agreement with the exact theory but deviate significantly from the predictions of the proximity force approximation approach. This provides the quantitative confirmation for the observation of diffraction-type effects that are disregarded within the PFA approach. Possible applications of the phenomenon of the lateral Casimir force in nanotechnology for the operation of micromachines are discussed.

preprint2009arXiv

Comment on "Contribution of drifting carriers to the Casimir-Lifshitz and Casimir-Polder interactions with semiconductor materials"

Recently D. A. R. Dalvit and S. K. Lamoreaux arXiv:0805.1676 [Phys. Rev. Lett. v.101, 163203 (2008)] suggested the modification of the reflection coefficients in the Lifshitz theory taking into account the screening effects and diffusion currents. We demonstrate that the suggested modification is thermodynamically and experimentally inconsistent.

preprint2009arXiv

Demonstration of the asymmetric lateral Casimir force between corrugated surfaces in the nonadditive regime

The measurement of the lateral Casimir force between two aligned sinusoidally corrugated Au-coated surfaces has been performed in the nonadditive regime. The use of deeper corrugations also allowed to demonstrate an asymmetry in the phase dependences of the lateral Casimir force, as predicted earlier. The measurement data are found to be in excellent agreement with the exact theoretical results computed at T=300 K including effect of real material properties. The deviations between the exact theory and the proximity force approximation are quantified. The obtained results are topical for applications in nanomachines.

preprint2009arXiv

The Casimir force between real materials: experiment and theory

The physical origin of the Casimir force is connected with the existence of zero-point and thermal fluctuations. The Casimir effect is very general and finds applications in various fields of physics. This review is limited to the rapid progress at the intersection of experiment and theory that has been achieved in the last few years. It includes a critical assessment of the proposed approaches to the resolution of the puzzles arising in the applications of the Lifshitz theory of the van der Waals and Casimir forces to real materials. All the primary experiments on the measurement of the Casimir force between macroscopic bodies and the Casimir-Polder force between an atom and a wall that have been performed in the last decade are reviewed, including the theory needed for their interpretation. The methodology for the comparison between experiment and theory in the force-distance measurements is presented. The experimental and theoretical results described here provide a deeper understanding of the phenomenon of dispersion forces in real materials and offer guidance for the application of Lifshitz theory for the interpretation of the measurement results.

preprint2009arXiv

Why Screening Effects Do Not Influence the Casimir Force

The Lifshitz theory of dispersion forces leads to thermodynamic and experimental inconsistencies when the role of drifting charge carriers is included in the model of the dielectric response. Recently modified reflection coefficients were suggested that take into account screening effects and diffusion currents. We demonstrate that this theoretical approach leads to a violation of the third law of thermodynamics (Nernst's heat theorem) for a wide class of materials and is excluded by the data from two recent experiments. The physical reason for its failure is explained by the violation of thermal equilibrium, which is the fundamental applicability condition of the Lifshitz theory, in the presence of drift and diffusion currents.