Researcher profile

Timothy C. Green

Timothy C. Green contributes to research discovery and scholarly infrastructure.

ResearcherAffiliation not importedOpen to collaborate

Trust snapshot

Quick read

Trust 15 - UnverifiedVerification L1Unclaimed author
3works
0followers
3topics
3close collaborators

Actions

Decide how to stay connected

Follow researcher0

Identity and collaboration

How to connect with this researcher

Claiming links this public author record to a researcher profile and unlocks direct collaboration workflows.

Log in to claim

Direct collaboration

Open a focused conversation when the fit is right

Claim this author entity first to unlock direct invitations.

Research graph

See the researcher in context

Open full explorer

Inspect adjacent work, topics, institutions and collaborators without jumping out to a separate graph page.

Building this graph slice

BZPEER is loading the nearby papers, people, topics and institutions for this page.

Published work

3 published item(s)

preprint2022arXiv

Impedance-based Root-cause Analysis: Comparative Study of Impedance Models and Calculation of Eigenvalue Sensitivity

Impedance models of power systems are useful when state-space models of apparatus such as inverter-based resources (IBRs) have not been made available and instead only black-box impedance models are available. For tracing the root causes of poor damping and tuning modes of the system, the sensitivity of the modes to components and parameters are needed. The so-called critical admittance-eigenvalue sensitivity based on nodal admittance model has provided a partial solution but omits meaningful directional information. The alternative whole-system impedance model yields participation factors of shunt-connected apparatus with directional information that allows separate tuning for damping and frequency, yet do not cover series-connected components. This paper formalises the relationships between the two forms of impedance models and between the two forms of root-cause analysis. The calculation of system eigenvalue sensitivity in impedance models is further developed, which fills the gaps of previous research and establishes a complete theory of impedance-based root-cause analysis. The theoretical relationships and the tuning of parameters have been illustrated with a three-node passive network, a modified IEEE 14-bus network and a modified NETS-NYPS 68-bus network, showing that tools can be developed for tuning of IBR-rich power systems where only black-box impedance models are available.

preprint2022arXiv

Revisiting Grid-Forming and Grid-Following Inverters: A Duality Theory

Power electronic converters for integrating renewable energy resources into power systems can be divided into grid-forming and grid-following inverters. They possess certain similarities, but several important differences, which means that the relationship between them is quite subtle and sometimes obscure. In this article, a new perspective based on duality is proposed to create new insights. It successfully unifies the grid interfacing and synchronization characteristics of the two inverter types in a symmetric, elegant, and technology-neutral form. Analysis shows that the grid-forming and grid-following inverters are duals of each other in several ways including a) synchronization controllers: frequency droop control and phase-locked loop (PLL); b) grid-interfacing characteristics: current-following voltage-forming and voltage-following current-forming; c) swing characteristics: current-angle swing and voltage-angle swing; d) inner-loop controllers: output impedance shaping and output admittance shaping; and e) grid strength compatibility: strong-grid instability and weak-grid instability. The swing equations are also derived in dual form, which reveal the dynamic interaction between the grid strength, the synchronization controllers, and the inner-loop controllers. Insights are generated into cases of poor stability in both small-signal and transient/large-signal. The theoretical analysis and simulation results are used to illustrate cases for simple single-inverter-infinite-bus systems and a multi-inverter power network.

preprint2019arXiv

Interpreting Frame Transformations as Diagonalization of Harmonic Transfer Functions

Analysis of ac electrical systems can be performed via frame transformations in the time-domain or via harmonic transfer functions (HTFs) in the frequency-domain. The two approaches each have unique advantages but are hard to reconcile because the coupling effect in the frequency-domain leads to infinite dimensional HTF matrices that need to be truncated. This paper explores the relation between the two representations and shows that applying a similarity transformation to an HTF matrix creates a direct equivalence to a frame transformation on the input-output signals. Under certain conditions, such similarity transformations have a diagonalizing effect which, essentially, reduces the HTF matrix order from infinity to two or one, making the matrix tractable mathematically without truncation or approximation. This theory is applied to a droop-controlled voltage source inverter as an illustrative example. A stability criterion is derived in the frequency-domain which agrees with the conventional state-space model but offers greater insights into the mechanism of instability in terms of the negative damping (non-passivity) under droop control. The paper not only establishes a unified view in theory but also offers an effective practical tool for stability assessment.