Researcher profile

Tilman Weckesser

Tilman Weckesser contributes to research discovery and scholarly infrastructure.

ResearcherAffiliation not importedOpen to collaborate

Trust snapshot

Quick read

Trust 15 - UnverifiedVerification L1Unclaimed author
3works
0followers
3topics
4close collaborators

Actions

Decide how to stay connected

Follow researcher0

Identity and collaboration

How to connect with this researcher

Claiming links this public author record to a researcher profile and unlocks direct collaboration workflows.

Log in to claim

Direct collaboration

Open a focused conversation when the fit is right

Claim this author entity first to unlock direct invitations.

Research graph

See the researcher in context

Open full explorer

Inspect adjacent work, topics, institutions and collaborators without jumping out to a separate graph page.

Building this graph slice

BZPEER is loading the nearby papers, people, topics and institutions for this page.

Published work

3 published item(s)

preprint2020arXiv

Market Integration of HVDC Lines: Internalizing HVDC Losses in Market Clearing

Moving towards regional Supergrids, an increasing number of interconnections are formed by High Voltage Direct Current (HVDC) lines. Currently, in most regions, HVDC losses are not considered in market operations, resulting in additional costs for Transmission System Operators (TSOs). Nordic TSOs have proposed the introduction of HVDC loss factors in the market clearing algorithm, to account for the cost of losses and avoid HVDC flows between zones with zero price difference. In this paper, we introduce a rigorous framework to assess the introduction of loss factors, in particular HVDC loss factors, in nodal and zonal pricing markets. First, we focus on the identification of an appropriate loss factor. We propose and compare three different models: constant, linear, and piecewise linear. Second, we introduce formulations to include losses in market clearing algorithms. Carrying numerical tests for a whole year, we find that accounting only for HVDC or AC losses may lead to lower social welfare for a non-negligible amount of time. To counter this, this paper introduces a framework for including both AC and HVDC losses in a zonal or nodal pricing environment. We show both theoretically and through simulations that such a framework is guaranteed to increase social welfare.

preprint2020arXiv

North Sea Wind Power Hub: System Configurations, Grid Implementation and Techno-economic Assessment

In 2017, Energinet and TenneT, the Danish and Dutch Transmission System Operators (TSOs), have announced the North Sea Wind Power Hub (NSWPH) project. The project aims at increasing by 36 GW the North Sea offshore wind capacity, with an artificial island collecting all the power produced by wind turbines and several HVDC links transmitting this power to the onshore grids. This project brings together new opportunities and new challenges, both from a technical and economic point of view. In this regard, this paper presents three analyses regarding the design and operation of such an offshore system. First, we perform a techno-economic assessment of different grid configurations for the collection of the power produced by wind farms and its transmission to the hub. In this analysis, two frequencies and two voltage levels for the operation of the offshore grid are investigated. Our findings show that the nominal-frequency high-voltage option is the more suitable, as low-frequency does not bring any advantage and low-voltage would results in higher costs. The second analysis is related to the differences in operating the system with low- or zero-inertia; different dynamic studies are performed for each configuration to identify proper control actions and their stability properties. Comparing the outcomes of the simulations, we observed that voltage and frequency oscillations are better damped in the zero-inertia system; however, the risk of propagating offshore faults in the connected onshore grids is mitigated with the inclusion of the synchronous condensers. Lastly, a comparison of ElectroMagnetic Transient (EMT) and phasor-mode (also known as RMS) models is presented, in order to understand their appropriateness of simulating low- and zero- inertia systems. The results show that phasor approximation modelling can be used, as long as eigen-frequencies in power network are well damped.

preprint2020arXiv

Zero-inertia Systems: Sufficient Conditions for Phasor Modeling

Time-domain simulations are a critical tool for power system operators. Depending on the instability mechanism under consideration and the system characteristics, such as the time constants of controllers, either phasor or Electro-Magnetic Transient (EMT) models should be employed. On the one hand, EMT models provide a detailed-modeling of the system dynamics, thus increase the reliability of stability analysis; on the other end, using these models increase the computational times of simulations, slowing down the security assessment process. To decrease computational time, system operators could resort to phasor-mode simulations for a (hopefully large) subset of disturbances. This paper investigates the appropriateness of phasor-approximation models on simulating events related to power supply and balance stability in zero-inertia systems. First, the stability boundaries, which each model is able to identify, are analyzed; then sufficient conditions for control parameters are derived, which allow using phasor-approximation models to monitor power sharing among grid-forming converter-based resources. Time-domain simulations are performed in PowerFactory DigSilent to verify the results.