Source author record

Tianling Lyu

Tianling Lyu appears in the imported research catalog. Authorship, coauthor and topic links are available while profile ownership is still unclaimed.

ResearcherUnclaimed source record

Catalog footprint

What is connected

2works
2topics
4close collaborators

Actions

Connect this record

Log in to claim

Research graph

See the researcher in context

Open full explorer

Inspect adjacent papers, topics, institutions and collaborators without losing the researcher page.

Building this map preview

BZPEER is loading the nearby papers, people, topics and institutions for this page.

Published work

2 published item(s)

preprint2020arXiv

A deep learning approach for virtual monochromatic spectral CT imaging with a standard single energy CT scanner

Purpose/Objectives: To develop and assess a strategy of using deep learning (DL) to generate virtual monochromatic CT (VMCT) images from a single-energy CT (SECT) scan. Materials/Methods: The proposed data-driven VMCT imaging consists of two steps: (i) using a supervised DL model trained with a large number of 100 kV and 140 kV dual-energy CT (DECT) image pairs to produce the corresponding high-energy CT image from a low-energy image; and (ii) reconstructing VMCT images with energy ranging from 40 to 150 keV. To evaluate the performance of the method, we retrospectively studied 6,767 abdominal DECT images. The VMCT images reconstructed using both DL-derived DECT (DL-DECT) images and the images from DECT scanner were compared quantitatively. Paired-sample t-tests were used for statistical analysis to show the consistency and precision of calculated HU values. Results: Excellent agreement was found between the DL-DECT and the ground truth DECT images (p values ranged from 0.50 to 0.95). Noise reduction up to 68% (from 163 HU to 51 HU) was achieved for DL-based VMCT imaging as compared to that obtained by using the standard DECT. For the DL-based VMCT, the maximum iodine contrast-to-noise ratio (CNR) for each patient (ranging from 15.1 to 16.6) was achieved at 40 keV. In addition to the enormous benefit of VMCT acquisition with merely a SECT image, an improvement of CNR as high as 55% (from 10.7 to 16.6) was attained with the proposed approach. Conclusions: This study demonstrates that high-quality VMCT images can be obtained with only a SECT scan.

preprint2020arXiv

Dual-energy CT imaging from single-energy CT data with material decomposition convolutional neural network

Dual-energy computed tomography (DECT) is of great significance for clinical practice due to its huge potential to provide material-specific information. However, DECT scanners are usually more expensive than standard single-energy CT (SECT) scanners and thus are less accessible to undeveloped regions. In this paper, we show that the energy-domain correlation and anatomical consistency between standard DECT images can be harnessed by a deep learning model to provide high-performance DECT imaging from fully-sampled low-energy data together with single-view high-energy data, which can be obtained by using a scout-view high-energy image. We demonstrate the feasibility of the approach with contrast-enhanced DECT scans from 5,753 slices of images of twenty-two patients and show its superior performance on DECT applications. The deep learning-based approach could be useful to further significantly reduce the radiation dose of current premium DECT scanners and has the potential to simplify the hardware of DECT imaging systems and to enable DECT imaging using standard SECT scanners.