Source author record

the HEGRA Collaboration

the HEGRA Collaboration appears in the imported research catalog. Authorship, coauthor and topic links are available while profile ownership is still unclaimed.

ResearcherUnclaimed source record

Catalog footprint

What is connected

3works
1topics
4close collaborators

Actions

Connect this record

Log in to claim

Research graph

See the researcher in context

Open full explorer

Inspect adjacent papers, topics, institutions and collaborators without losing the researcher page.

Building this map preview

BZPEER is loading the nearby papers, people, topics and institutions for this page.

Published work

3 published item(s)

preprint2003arXiv

The Technical Performance of the HEGRA System of Imaging Air Cherenkov Telescopes

Between early 1997 and late 2002, the HEGRA collaboration operated a stereoscopic system of 4 (later 5) imaging atmospheric Cherenkov telescopes. In this paper we present the calibration schemes which were developed for the system, and report on the performance of the detector over the years. In general, the telescope system was very well understood, regarding both the absolute calibration and the slight changes in performance over the years. The system had an energy threshold of 500 GeV for observations at zenith and under optimum detector conditions. With the corresponding calibration schemes, a systematic accuracy of 15 percent on the absolute energy scale has been achieved. The continuous sensitivity monitoring provided a relative accuracy of a few percent, and showed that the threshold did not exceed 600 GeV throughout the entire operation time. The readout electronics and the imaging quality of the dishes were well monitored and stable. The absolute pointing had an accuracy of at least 25 arcsec; this number was guaranteed throughout the whole lifetime of the experiment.

preprint2000arXiv

Rejection of the hypothesis that Markarian 501 TeV photons are pure Bose-Einstein condensates

The energy spectrum of the Blazar type galaxy Markarian 501 (Mrk 501) as measured by the High-Energy-Gamma-Ray Astronomy (HEGRA) air Cerenkov telescopes extends beyond 16 TeV and constitutes the most energetic photons observed from an extragalactic object. A fraction of the emitted spectrum is possibly absorbed in interactions with low energy photons of the diffuse extragalactic infrared radiation, which in turn offers the unique possibility to measure the diffuse infrared radiation density by TeV spectroscopy. The upper limit on the density of the extragalactic infrared radiation derived from the TeV observations imposes constraints on models of galaxy formation and stellar evolution. One of the recently published ideas to overcome severe absorption of TeV photons is based upon the assumption that sources like Mrk 501 could produce Bose-Einstein condensates of coherent photons. The condensates would have a higher survival probability during the transport in the diffuse radiation field and could mimic TeV air shower events. The powerful stereoscopic technique of the HEGRA air Cerenkov telescopes allows to test this hypothesis by reconstructing the penetration depths of TeV air shower events: Air showers initiated by Bose-Einstein condensates are expected to reach the maximum of the shower development in the atmosphere earlier than single photon events. By comparing the energy-dependent penetration depths of TeV photons from Mrk 501 with those from the TeV standard-candle Crab Nebula and simulated air shower events, we can reject the hypothesis that TeV photons from Mrk 501 are pure Bose-Einstein condensates.

preprint1999arXiv

Energy Spectrum and Chemical Composition of Cosmic Rays between 0.3 and 10 PeV determined from the Cherenkov-Light and Charged-Particle distributions in Air Showers

Measurements of the lateral distribution of Cherenkov photons with the wide-angle atmospheric Cherenkov light detector array AIROBICC and of the charged particle lateral distribution with the scintillator matrix of the HEGRA air-shower detector complex in air showers are reported. With the atmospheric shower-front sampling technique these detectors measure the electromagnetic component of an extensive air shower via the lateral density distribution of the shower particles and of the Cherenkov photons. The data are compared with events generated with the CORSIKA program package with the QGSJET hadronic-event generator. Consistency checks performed with primary energy-reconstruction methods based on different shower observables indicate satisfactory agreement between these extensive air shower simulations and the experimental data. The energy spectrum features a so called ``knee'' at an energy of E_knee = 3.98 (+4.66) (-0.83) (stat) +- 0.53 (syst) PeV. Power law fits to the differential energy spectrum yield indices of -2.72 (+0.02)(-0.03) (stat) +- 0.07 (syst) below, and -3.22 (+0.47) (-0.59) (stat) +- 0.08 (syst)} above the knee. The best-fit elongation rate for the whole energy range is determined to 78.3 +- 1.0 (stat) +- 6.2 (syst) g/cm^2. At the highest energies it seems to decrease slightly.The best-fit fraction of light nuclei decreases from 37 (+28) (-21) % (combined statistical and systematic) to 8 (+32) (-8) % (combined statistical and systematic) in the energy range discussed here. A detailed study of the systematic errors reveals that a non-changing composition cannot be excluded.