Source author record

Taku Inaniwa

Taku Inaniwa appears in the imported research catalog. Authorship, coauthor and topic links are available while profile ownership is still unclaimed.

ResearcherUnclaimed source record

Catalog footprint

What is connected

2works
1topics
4close collaborators

Actions

Connect this record

Log in to claim

Research graph

See the researcher in context

Open full explorer

Inspect adjacent papers, topics, institutions and collaborators without losing the researcher page.

Building this map preview

BZPEER is loading the nearby papers, people, topics and institutions for this page.

Published work

2 published item(s)

preprint2012arXiv

Relationship between electron density and effective densities of body tissues for stopping, scattering, and nuclear interaction of proton and ion beams

Purpose: In treatment planning of charged-particle radiotherapy, patient heterogeneity is conventionally modeled as variable-density water converted from CT images to best reproduce the stopping power, which may lead to inaccuracies in the handling of multiple scattering and nuclear interactions. Although similar conversions can be defined for these individual interactions, they would be valid only for specific CT systems and would require additional tasks for clinical application. This study aims to improve the practicality of the interaction-specific heterogeneity correction. Methods: We calculated the electron densities and effective densities for stopping power, multiple scattering, and nuclear interactions of protons and ions, using the standard elemental-composition data for body tissues to construct the invariant conversion functions. We also simulated a proton beam in a lung-like geometry and a carbon-ion beam in a prostate-like geometry to demonstrate the procedure and the effects of the interaction-specific heterogeneity correction. Results: Strong correlations were observed between the electron density and the respective effective densities, with which we formulated polyline conversion functions. Their effects amounted to 10% differences in multiple-scattering angle and nuclear-interaction mean free path for bones compared to those in the conventional heterogeneity correction. Although their realistic effect on patient dose distributions would be generally small, it could be at the level of a few percent when a beam traverses a large bone. Conclusions: The present conversion functions are invariant and may be incorporated in treatment planning systems with a common function relating CT number to electron density. This will enable improved beam dose calculation while minimizing initial setup and quality management of the user's specific system.

preprint2010arXiv

Robust dual-field optimization of scanned ion beams against range and setup uncertainties

A 'dual-field' strategy is often used for tumors with highly complex shapes and/or with large volumes exceeding available field-size in both passive and scanning irradiations with ion beams. Range and setup uncertainties can cause hot and cold doses at the field junction within the target. Such uncertainties will also cause cold doses in the peripheral region of the target. We have developed an algorithm to reduce the sensitivity of the dual-field plan to these uncertainties in scanning irradiations. This algorithm is composed of the following two steps: 1) generating the expanded target volume, and 2) solving the inverse problem where the terms suppressing the dose gradient of individual fields are added into the objective function. The validity of this algorithm is demonstrated through the simulation studies for three extreme cases of two fields with unidirectional, opposing and orthogonal geometries. With the proposed algorithm, we can obtain a more robust plan to minimize the effects of range and setup uncertainties than the conventional plan. Compared to that for the conventional plan, the optimization time for the robust plan increased by a factor of approximately three.