Researcher profile

Taisir E. H. Elgorashi

Taisir E. H. Elgorashi contributes to research discovery and scholarly infrastructure.

ResearcherAffiliation not importedOpen to collaborate

Trust snapshot

Quick read

Trust 21 - EmergingVerification L1Unclaimed author
6works
0followers
2topics
4close collaborators

Actions

Decide how to stay connected

Follow researcher0

Identity and collaboration

How to connect with this researcher

Claiming links this public author record to a researcher profile and unlocks direct collaboration workflows.

Log in to claim

Direct collaboration

Open a focused conversation when the fit is right

Claim this author entity first to unlock direct invitations.

Research graph

See the researcher in context

Open full explorer

Inspect adjacent work, topics, institutions and collaborators without jumping out to a separate graph page.

Building this graph slice

BZPEER is loading the nearby papers, people, topics and institutions for this page.

Published work

6 published item(s)

preprint2021arXiv

Optimized Energy Efficient Virtualization and Content Caching in 5G Networks

Network function virtualization (NFV) and content caching are two promising technologies that hold great potential for network operators and designers. This paper optimizes the deployment of NFV and content caching in 5G networks and focuses on the associated power consumption savings. In addition, it introduces an approach to combine content caching with NFV in one integrated architecture for energy aware 5G networks. A mixed integer linear programming (MILP) model has been developed to minimize the total power consumption by jointly optimizing the cache size, virtual machine (VM) workload, and the locations of both cache nodes and VMs. The results were investigated under the impact of core network virtual machines (CNVMs) inter-traffic. The result show that the optical line terminal (OLT) access network nodes are the optimum location for content caching and for hosting VMs during busy times of the day whilst IP over WDM core network nodes are the optimum locations for caching and VM placement during off-peak time. Furthermore, the results reveal that a virtualization-only approach is better than a caching-only approach for video streaming services where the virtualization-only approach compared to caching-only approach, achieves a maximum power saving of 7% (average 5%) when no CNVMs inter-traffic is considered and 6% (average 4%) with CNVMs inter-traffic at 10% of the total backhaul traffic. On the other hand, the integrated approach has a maximum power saving of 15% (average 9%) with and without CNVMs inter-traffic compared to the virtualization-only approach, and it achieves a maximum power saving of 21% (average 13%) without CNVMs inter-traffic and 20% (average 12%) when CNVMs inter-traffic is considered compared with the caching-only approach. In order to validate the MILP models and achieve real-time operation in our approaches, a heuristic was developed.

preprint2020arXiv

Beam Blockage in Optical Wireless Systems

In this paper, we use the percentage blockage as a metric when an opaque disc obstructs the Line-of-Sight link from the access point to the receiver in an optical wireless indoor communication system. The effect of the different parameters of the obstructing object are studied, these are the radius, the height, and the horizontal distance from the receiver in the positive y direction. The percentage of blocked room locations to the total number of room locations when varying the disc parameters is studied assuming a single serving link. It was found that depending on the dimensions of the obstructing object and the distance from the receiver in addition to which access point is serving the user, that blockage can vary between 0% up to 100%. Furthermore, the service received by a user, in terms of beam blockage depends on the access point they are connected to. The resulting fairness challenges will be addressed in resource allocation optimization in future work.

preprint2020arXiv

Blackout Resilient Optical Core Network

A disaster may not necessarily demolish the telecommunications infrastructure, but instead it might affect the national grid and cause blackouts, consequently disrupting the network operation unless there is an alternative power source(s). In this paper, power outages are considered, and the telecommunication network performance is evaluated during a blackout. Two approaches are presented to minimize the impact of power outage and maximize the survival time of the blackout node. A mixed integer linear programming (MILP) model is developed to evaluate the network performance under a single node blackout scenario. The model is used to evaluate the network under the two proposed scenarios. The results show that the proposed approach succeeds in extending the network life time while minimizing the required amount of backup energy.

preprint2020arXiv

Energy Efficient Cloud-Fog Architecture

The advancements of cloud computing came as a radical transformation in the way Information and Communication Technology (ICT) services are deployed and maintained. Cloud computing provides ubiquitous on-demand access to an Internet-based pool of processing, storage, and communication resources offered to a large set of geographically distributed users. As the cloud computing infrastructure grows and demand increases, the need for a new breed of on-demand computing that can efficiently maintain Quality of Service (QoS) requirements has increased. Fog computing was proposed to address the limitations of cloud computing, in terms of delay and high bandwidth requirements, by extending the on-demand resources of clouds to the edge of the network bringing them closer to the users. The massive growth and wide use of cloud-fog services have created serious power consumption concerns. This article delves into the energy consumption of cloud-fog services by raising headline questions related to; how significant the problem itself is, how different conditions/scenarios affect the energy consumption of the architecture, and how to orchestrate the use of the architecture in an energy-efficient manner. We start by summarizing the cloud-fog architecture including different communication and computing layers. Additionally, we give a brief overview of the role of Virtual Machine (VM) placement in optimally using cloud-fog resources in a dynamic manner. Then, we present the problem of energy efficient VMs placement and provide numerical results.

preprint2020arXiv

Energy Efficient Virtual Machines Placement over Cloud-Fog Network Architecture

Fog computing is an emerging paradigm that aims to improve the efficiency and QoS of cloud computing by extending the cloud to the edge of the network. This paper develops a comprehensive energy efficiency analysis framework based on mathematical modeling and heuristics to study the offloading of virtual machine (VM) services from the cloud to the fog. The analysis addresses the impact of different factors including the traffic between the VM and its users, the VM workload, the workload versus number of users profile and the proximity of fog nodes to users. Overall, the power consumption can be reduced if the VM users traffic is high and/or the VMs have a linear power profile. In such a linear profile case, the creation of multiple VM replicas does not increase the computing power consumption significantly (there may be a slight increase due to idle / baseline power consumption) if the number of users remains constant, however the VM replicas can be brought closer to the end users, thus reducing the transport network power consumption. In our scenario, the optimum placement of VMs over a cloud-fog architecture significantly decreased the total power consumption by 56% and 64% under high user data rates compared to optimized distributed clouds placement and placement in the existing AT&T network cloud locations, respectively.

preprint2020arXiv

Resilience in Optical Wireless Systems

High reliability and availability of communication services is a key requirement that needs to be ensured by service providers. Since the direct line-of-sight (LOS) beam is prone to blockage in indoor optical wireless communication systems, a backup link needs to be at hand in case of blockage, and hence channel allocation algorithms should be blockage-aware. In this paper, the impact of beam blockage due to a disc with varying size and distance from the receiver is studied where blockage is quantitatively evaluated using percentage blockage for 512 room locations at 25 cm separation. It was found that assigning two links with maximum separation between the serving access points can reduce or eliminate blockage compared to the case when resilience is not implemented. Increasing the number of allocated access points per user further increases resilience.