Source author record

T. Suehara

T. Suehara appears in the imported research catalog. Authorship, coauthor and topic links are available while profile ownership is still unclaimed.

ResearcherUnclaimed source record

Catalog footprint

What is connected

26works
7topics
4close collaborators

Actions

Connect this record

Log in to claim

Research graph

See the researcher in context

Open full explorer

Inspect adjacent papers, topics, institutions and collaborators without losing the researcher page.

Building this map preview

BZPEER is loading the nearby papers, people, topics and institutions for this page.

Published work

26 published item(s)

preprint2020arXiv

Performance evaluation of a silicon strip detector for positrons/electrons from a pulsed a muon beam

A high-intensity pulsed muon beam is becoming available at the at the Japan Proton Accelerator Research Complex (J-PARC). Many experiments to study fundamental physics using this high-intensity muon beam are proposed. An experiment to measure the muon magnetic moment anomaly ($g-2$) and the muon electric dipole moment (EDM) is one of these experiments and it requires a tracking detector for positrons from muon decay. Fine segmentation is required in a detector to tolerate the high rate of positrons. The time resolution is required to be much better than the muon anomalous spin precession period while a buffer depth of a front-end electronics needs to be much longer than the accelerated muon lifetime. Requirements of this detector also meet requirements of a measurement of the muonium hyperfine structure interval at the J-PARC and another experiment to measure the proton charge radius at Tohoku University. We have developed a single-sided silicon strip sensor with a 190 $μ$m pitch, a front-end electronics with a sampling rate of 200 MHz and a buffer memory depth of 8192, and a data acquisition system based on DAQ-Middleware for the J-PARC muon $g-2$/EDM experiment. We have fabricated detector modules consisting of this sensor and the front-end electronics. Performance of fabricated detector modules was evaluated at a laboratory and a beam test using the positron beam at Tohoku University. The detector is confirmed to satisfy all requirements of the experiments except for the time walk, which will be solved by the next version of a front-end electronics.

preprint2020arXiv

Study of Position Sensitive Silicon Detector (PSD) for SiW-ECAL at ILC

We are developing position sensitive silicon detectors (PSDs) which have an electrode at each of four corners so that incident position of a charged particle can be obtained with signal from the electrodes. It is expected that the position resolution of the electromagnetic calorimeter (ECAL) of the ILD detector will be improved by introducing PSDs to detection layers. We have been developing the PSDs for several years. In the previous production we found that the charge separation is not optimally done due to the readout impedance. To solve the issue, we produced new PSDs with higher surface resistance with an additional resistive layer on the surface. We also implemented several techniques to decrease position distortion and increase signal-to-noise ratio which are essential for the optimal position resolution. The measurements on the prototype sensors are ongoing, including radiation source measurement and laser measurement using an ASIC for silicon pad detectors.

preprint2020arXiv

Study of silicon sensors for precise timing measurement

Silicon sensors with high time resolution can help particle identification in the International Linear Collider (ILC). We are studying Low Gain Avalanche Diodes (LGADs) as a high timing resolution sensor. As a step to develop LGADs, we are now focusing to characterize Avalanche Photo Diode (APD)s, because the APDs has the same multiplication structure as LGADs. We studied the characteristics of APDs with particles from radioisotopes.

preprint2019arXiv

Analysis of Testbeam Data of the Highly Granular RPC-Steel CALICE Digital Hadron Calorimeter and Validation of Geant4 Monte Carlo Models

We present a study of the response of the highly granular Digital Hadronic Calorimeter with steel absorbers, the Fe-DHCAL, to positrons, muons, and pions with momenta ranging from 2 to 60 GeV/c. Developed in the context of the CALICE collaboration, this hadron calorimeter utilises Resistive Plate Chambers as active media, interspersed with steel absorber plates. With a transverse granularity of $1\,\times\,1\,$cm$^{2}$ and a longitudinal segmentation of 38 layers, the calorimeter counted 350,208 readout channels, each read out with single-bit resolution (digital readout). The data were recorded in the Fermilab test beam in 2010-11. The analysis includes measurements of the calorimeter response and the energy resolution to positrons and muons, as well as detailed studies of various shower shape quantities. The results are compared to simulations based on Geant4, which utilise different electromagnetic and hadronic physics lists.

preprint2019arXiv

Beam test performance of the highly granular SiW-ECAL technological prototype for the ILC

The technological prototype of the CALICE highly granular silicon-tungsten electromagnetic calorimeter (SiW-ECAL) was tested in a beam at DESY in 2017. The setup comprised seven layers of silicon sensors. Each layer comprised four sensors, with each sensor containing an array of 256 $5.5\times5.5$ mm$^2$ silicon PIN diodes. The four sensors covered a total area of $18\times18$ cm$^2$, and comprised a total of 1024 channels. The readout was split into a trigger line and a charge signal line. Key performance results for signal over noise for the two output lines are presented, together with a study of the uniformity of the detector response. Measurements of the response to electrons for the tungsten loaded version of the detector are also presented.

preprint2019arXiv

EUDAQ $-$ A Data Acquisition Software Framework for Common Beam Telescopes

EUDAQ is a generic data acquisition software developed for use in conjunction with common beam telescopes at charged particle beam lines. Providing high-precision reference tracks for performance studies of new sensors, beam telescopes are essential for the research and development towards future detectors for high-energy physics. As beam time is a highly limited resource, EUDAQ has been designed with reliability and ease-of-use in mind. It enables flexible integration of different independent devices under test via their specific data acquisition systems into a top-level framework. EUDAQ controls all components globally, handles the data flow centrally and synchronises and records the data streams. Over the past decade, EUDAQ has been deployed as part of a wide range of successful test beam campaigns and detector development applications.

preprint2016arXiv

DHCAL with Minimal Absorber: Measurements with Positrons

In special tests, the active layers of the CALICE Digital Hadron Calorimeter prototype, the DHCAL, were exposed to low energy particle beams, without being interleaved by absorber plates. The thickness of each layer corresponded approximately to 0.29 radiation lengths or 0.034 nuclear interaction lengths, defined mostly by the copper and steel skins of the detector cassettes. This paper reports on measurements performed with this device in the Fermilab test beam with positrons in the energy range of 1 to 10 GeV. The measurements are compared to simulations based on GEANT4 and a standalone program to emulate the detailed response of the active elements.

preprint2016arXiv

Hadron shower decomposition in the highly granular CALICE analogue hadron calorimeter

The spatial development of hadronic showers in the CALICE scintillator-steel analogue hadron calorimeter is studied using test beam data collected at CERN and FNAL for single positive pions and protons with initial momenta in the range from 10 to 80 GeV/c. Both longitudinal and radial development of hadron showers are parametrised with two-component functions. The parametrisation is fit to test beam data and simulations using the QGSP_BERT and FTFP_BERT physics lists from Geant4 version 9.6. The parameters extracted from data and simulated samples are compared for the two types of hadrons. The response to pions and the ratio of the non-electromagnetic to the electromagnetic calorimeter response, h/e, are estimated using the extrapolation and decomposition of the longitudinal profiles.

preprint2016arXiv

Resistive Plate Chamber Digitization in a Hadronic Shower Environment

The CALICE Semi-Digital Hadron Calorimeter (SDHCAL) technological prototype is a sampling calorimeter using Glass Resistive Plate Chamber detectors with a three-threshold readout as the active medium. This technology is one of the two options proposed for the hadron calorimeter of the International Large Detector for the International Linear Collider. The prototype was exposed to beams of muons, electrons and pions of different energies at the CERN Super Proton Synchrotron. To be able to study the performance of such a calorimeter in future experiments it is important to ensure reliable simulation of its response. In this paper we present our prototype simulation performed with GEANT4 and the digitization procedure achieved with an algorithm called SimDigital. A detailed description of this algorithm is given and the methods to determinate its parameters using muon tracks and electromagnetic showers are explained. The comparison with hadronic shower data shows a good agreement up to 50 GeV. Discrepancies are observed at higher energies. The reasons for these differences are investigated.

preprint2015arXiv

Hybrid ECAL: Optimization and Related Developments

Hybrid ECAL is a cost-conscious option of electromagnetic calorimeter (ECAL) for particle flow calorimetry to be used in a detector of International Linear Collider (ILC). It is a combination of silicon-tungsten ECAL, which realizes high granularity and robust measurement of electromagnetic shower, and scintillator-tungsten ECAL, which gives affordable cost with similar performance to silicon. Optimization and a data acquisition trial in a test bench for the hybrid ECAL are described in this article.

preprint2015arXiv

Pion and proton showers in the CALICE scintillator-steel analogue hadron calorimeter

Showers produced by positive hadrons in the highly granular CALICE scintillator-steel analogue hadron calorimeter were studied. The experimental data were collected at CERN and FNAL for single particles with initial momenta from 10 to 80 GeV/c. The calorimeter response and resolution and spatial characteristics of shower development for proton- and pion-induced showers for test beam data and simulations using Geant4 version 9.6 are compared.

preprint2015arXiv

Shower development of particles with momenta from 15 GeV to 150 GeV in the CALICE scintillator-tungsten hadronic calorimeter

We present a study of showers initiated by electrons, pions, kaons, and protons with momenta from 15 GeV to 150 GeV in the highly granular CALICE scintillator-tungsten analogue hadronic calorimeter. The data were recorded at the CERN Super Proton Synchrotron in 2011. The analysis includes measurements of the calorimeter response to each particle type as well as measurements of the energy resolution and studies of the longitudinal and radial shower development for selected particles. The results are compared to Geant4 simulations (version 9.6.p02). In the study of the energy resolution we include previously published data with beam momenta from 1 GeV to 10 GeV recorded at the CERN Proton Synchrotron in 2010.

preprint2015arXiv

Testing Hadronic Interaction Models using a Highly Granular Silicon-Tungsten Calorimeter

A detailed study of hadronic interactions is presented using data recorded with the highly granular CALICE silicon-tungsten electromagnetic calorimeter. Approximately 350,000 selected negatively charged pion events at energies between 2 and 10 GeV have been studied. The predictions of several physics models available within the Geant4 simulation tool kit are compared to this data. A reasonable overall description of the data is observed; the Monte Carlo predictions are within 20% of the data, and for many observables much closer. The largest quantitative discrepancies are found in the longitudinal and transverse distributions of reconstructed energy.

preprint2014arXiv

First Millimeter-wave Spectroscopy of the Ground-state Positronium

We report on the first measurement of the Breit-Wigner resonance of the transition from {\it ortho-}positronium to {\it para-}positronium. We have developed an optical system to accumulate a power of over 20 kW using a frequency-tunable gyrotron and a Fabry-Pérot cavity. This system opens a new era of millimeter-wave spectroscopy, and enables us to directly determine both the hyperfine interval and the decay width of {\it p-}Ps.

preprint2014arXiv

Higgs Working Group Report of the Snowmass 2013 Community Planning Study

This report summarizes the work of the Energy Frontier Higgs Boson working group of the 2013 Community Summer Study (Snowmass). We identify the key elements of a precision Higgs physics program and document the physics potential of future experimental facilities as elucidated during the Snowmass study. We study Higgs couplings to gauge boson and fermion pairs, double Higgs production for the Higgs self-coupling, its quantum numbers and $CP$-mixing in Higgs couplings, the Higgs mass and total width, and prospects for direct searches for additional Higgs bosons in extensions of the Standard Model. Our report includes projections of measurement capabilities from detailed studies of the Compact Linear Collider (CLIC), a Gamma-Gamma Collider, the International Linear Collider (ILC), the Large Hadron Collider High-Luminosity Upgrade (HL-LHC), Very Large Hadron Colliders up to 100 TeV (VLHC), a Muon Collider, and a Triple-Large Electron Positron Collider (TLEP).

preprint2012arXiv

Direct Observation of the Hyperfine Transition of the Ground State Positronium

We report the first direct measurement of the hyperfine transition of the ground state positronium. The hyperfine structure between ortho-positronium and para-positronium is about 203 GHz. We develop a new optical system to accumulate about 10 kW power using a gyrotron, a mode converter, and a Fabry-Pérot cavity. The hyperfine transition has been observed with a significance of 5.4 standard deviations. The transition probability is measured to be $A = 3.1^{+1.6}_{-1.2} \times 10^{-8}$ s$^{-1}$ for the first time, which is in good agreement with the theoretical value of $3.37 \times 10^{-8}$ s$^{-1}$.

preprint2012arXiv

Present status and first results of the final focus beam line at the KEK Accelerator Test Facility

ATF2 is a final-focus test beam line which aims to focus the low emittance beam from the ATF damping ring to a vertical size of about 37 nm and to demonstrate nanometer level beam stability. Several advanced beam diagnostics and feedback tools are used. In December 2008, construction and installation were completed and beam commissioning started, supported by an international team of Asian, European, and U.S. scientists. The present status and first results are described.

preprint2011arXiv

First direct measurement of positronium hyperfine splitting with sub-THz light

Positronium is an ideal system for the research of the bound state QED. The hyperfine splitting of positronium (Ps-HFS, about 203 GHz) is an important observable but all previous measurements of Ps-HFS had been measured indirectly using Zeeman splitting. There might be the unknown systematic errors on the uniformity of magnetic field. We are trying to measure Ps-HFS directly using sub-THz radiation. We developed an optical system to accumulate high power (about 10 kW) radiation in a Fabry-Pérot resonant cavity and observed the positronium hyperfine transition for the first time.

preprint2011arXiv

Precise measurement of positronium hyperfine splitting using the Zeeman effect

Positronium is an ideal system for the research of the quantum electrodynamics (QED) in bound state. The hyperfine splitting (HFS) of positronium, $Δ_{\mathrm{HFS}}$, gives a good test of the bound state calculations and probes new physics beyond the Standard Model. A new method of QED calculations has revealed the discrepancy by 15\,ppm (3.9$σ$) of $Δ_{\mathrm{HFS}}$ between the QED prediction and the experimental average. There would be possibility of new physics or common systematic uncertainties in the previous all experiments. We describe a new experiment to reduce possible systematic uncertainties and will provide an independent check of the discrepancy. We are now taking data and the current result of $Δ_{\mathrm{HFS}} = 203.395\,1 \pm 0.002\,4 (\mathrm{stat.}, 12\,\mathrm{ppm}) \pm 0.001\,9 (\mathrm{sys.}, 9.5\,\mathrm{ppm})\,\mathrm{GHz} $ has been obtained so far. A measurement with a precision of $O$(ppm) is expected within a year.

preprint2010arXiv

Identification of new physics and general WIMP search at the ILC

We investigate the possibility of the identification of TeV physics models including WIMP dark matter at the International Linear Collider. Many TeV physics models contain a WIMP dark matter (chi^0) and charged new particle (chi^{pm}) which interacts with the WIMP dark matter via the vertex chi^{pm} chi^0 W^{mp}. Through Monte Carlo simulations, we study the process, e^+e^- to chi^+ chi^- to chi^0 chi^0 W^+ W^-, because the signal contains the fruitful information of the model. We show that, in particular, the distribution of the chi^{pm} production angle is the powerful probe in the TeV physics model search.

preprint2010arXiv

New method of precise measurement of positronium hyperfine splitting

The ground state hyperfine splitting of positronium, $Δ_{\mathrm{HFS}}$, is sensitive to high order corrections of QED. A new calculation up to $\mathrm{O}(α^3 \ln α)$ has revealed a $3.9σ$ discrepancy between the QED prediction and the experimental results. This discrepancy might either be due to systematic problems in the previous experiments or to contributions beyond the Standard Model. We propose an experiment to measure $Δ_{\mathrm{HFS}}$ employing new methods designed to remedy the systematic errors which may have affected the previous experiments. Our experiment will provide an independent check of the discrepancy. The prototype run has been finished and a result of $Δ_{\mathrm{HFS}} = 203.380 4 \pm 0.008 4 \mathrm{GHz} (41 \mathrm{ppm})$ has been obtained. A measurement with a precision of O(ppm) is expected within a few years.

preprint2010arXiv

Precise measurement of Hyper Fine Structure of positronium using sub-THz light

Positronium is an ideal system for the research of the QED, especially for the QED in bound state. The discrepancy of 3.9σis found recently between the measured HFS values and the QED prediction ($O(α^3)$). It might be due to the contribution of the unknown new physics or the systematic problems in the previous all measurements. We propose new method to measure HFS precisely and directly. A gyrotron, a novel sub-THz light source is used with a high-finesse Fabry-Pérot cavity to obtain enough radiation power at 203 GHz. The present status of the optimization studies and current design of the experiment are described.

preprint2010arXiv

Shintake Monitor in ATF2: Performance Evaluation

The beam test for the Shintake monitor succeeded in measuring signal modulation with the laser interference fringe pattern in November 2009. We have studied the error sources, and evaluated the systematic error to be less than 30% for 1 minute measurements. This paper centers on the evaluation of the Shintake monitor performance through analyzing beam tests deta. Most systematic error sources are well understood, enabling accurate measurement of the beam size when it reaches 37 nm.

preprint2010arXiv

Simulation Study of W Boson + Dark Matter Signatures for Identification of New Physics

Identification of beyond-standard-models including WIMP dark matter is studied in four particle final state with a W boson pair and a WIMP pair at the International Linear Collider. Models with different spin structures give distinguishable production angle distributions. After the mass determination in each model, the production angle is reconstructed using the four momentum of W bosons with a back-to-back constraint. Three models of Inert Higgs, Supersymmetry and Little Higgs are considered. Discrimination power at 200 fb and 40 fb signal cross section with 500 fb-1 luminosity at sqrt(s) = 500 GeV is obtained.

preprint2009arXiv

Precise measurement of HFS of positronium

The ground state hyperfine splitting in positronium, $Δ_{\mathrm{HFS}}$, is sensitive to high order corrections of QED. A new calculation up to $O(α^3)$ has revealed a $3.9 σ$ discrepancy between the QED prediction and the experimental results. This discrepancy might either be due to systematic problems in the previous experiments or to contributions beyond the Standard Model. We propose an experiment to measure $Δ_{\mathrm{HFS}}$ employing new methods designed to remedy the systematic errors which may have affected the previous experiments. Our experiment will provide an independent check of the discrepancy. The measurement is in progress and a preliminary result of $Δ_{\mathrm{HFS}} = 203.399 \pm 0.029 \mathrm{GHz} (143 \mathrm{ppm})$ has been obtained. A measurement with a precision of O(1) ppm is expected within a few years.