Researcher profile

T. Kozlowski

T. Kozlowski contributes to research discovery and scholarly infrastructure.

ResearcherAffiliation not importedOpen to collaborate

Trust snapshot

Quick read

Trust 21 - EmergingVerification L1Unclaimed author
7works
0followers
4topics
4close collaborators

Actions

Decide how to stay connected

Follow researcher0

Identity and collaboration

How to connect with this researcher

Claiming links this public author record to a researcher profile and unlocks direct collaboration workflows.

Log in to claim

Direct collaboration

Open a focused conversation when the fit is right

Claim this author entity first to unlock direct invitations.

Research graph

See the researcher in context

Open full explorer

Inspect adjacent work, topics, institutions and collaborators without jumping out to a separate graph page.

Building this graph slice

BZPEER is loading the nearby papers, people, topics and institutions for this page.

Published work

7 published item(s)

preprint2014arXiv

New results in rare allowed muon and pion decays

Simple dynamics, few available decay channels, and highly controlled radiative and loop corrections, make pion and muon decays a sensitive means of exploring details of the underlying symmetries. We review the current status of the rare decays: pi+ -> e+ nu, pi+ -> e+ nu gamma, pi+ -> pi0 e+ nu, and mu+ -> e+ nu nu-bar gamma. For the latter we report new preliminary values for the branching ratio B(E_gamma >10 MeV, theta_(e-gamma) > 30deg) = 4.365 (9)_stat (42)_syst x 10^{-3}, and the decay parameter eta-bar = 0.006 (17)_stat (18)_syst, both in excellent agreement with standard model predictions. We review recent measurements, particularly by the PIBETA and PEN experiments, and near-term prospects for improvement. These and other similar precise low energy studies complement modern collider results materially.

preprint2012arXiv

New studies of allowed pion and muon decays

Building on the rare pion and muon decay results of the PIBETA experiment, the PEN collaboration has undertaken a precise measurement of B_{πe2} = R^π_{e/μ}, the π^+ -> e^+ν(γ) decay branching ratio, at the Paul Scherrer Institute, to reduce the present 40\times experimental precision lag behind theory to ~ 6-7\times. Because of large helicity suppression, R^π_{e/μ} is uniquely sensitive to contributions from non-(V-A) physics, making this decay a particularly suitable subject of study. Even at current precision, the experimental value of B_{πe2} provides the most accurate test of lepton universality available. During runs in 2008-10, PEN has accumulated over 2\times 10^7 π_{e2} events; a comprehensive maximum-likelihood analysis is currently under way. The new data will also lead to improved precision of the earlier PIBETA results on radiative πand μdecays.

preprint2012arXiv

Technical Design Report for the: PANDA Micro Vertex Detector

This document illustrates the technical layout and the expected performance of the Micro Vertex Detector (MVD) of the PANDA experiment. The MVD will detect charged particles as close as possible to the interaction zone. Design criteria and the optimisation process as well as the technical solutions chosen are discussed and the results of this process are subjected to extensive Monte Carlo physics studies. The route towards realisation of the detector is outlined.

preprint2009arXiv

PEN experiment: a precise measurement of the pi+ -> e+ nu decay branching fraction

A new measurement of $B_{πe2}$, the $π^+ \to e^+ν(γ)$ decay branching ratio, is currently under way at the Paul Scherrer Institute. The present experimental result on $B_{πe2}$ constitutes the most accurate test of lepton universality available. The accuracy, however, still lags behind the theoretical precision by over an order of magnitude. Because of the large helicity suppression of the $π_{e2}$ decay, its branching ratio is susceptible to significant contributions from new physics, making this decay a particularly suitable subject of study.

preprint2009arXiv

Scintillator counters with WLS fiber/MPPC readout for the side muon range detector (SMRD)of the T2K experiment

The T2K neutrino experiment at J-PARC uses a set of near detectors to measure the properties of an unoscillated neutrino beam and neutrino interaction cross-sections. One of the sub-detectors of the near-detector complex, the side muon range detector (SMRD), is described in the paper. The detector is designed to help measure the neutrino energy spectrum, to identify background and to calibrate the other detectors. The active elements of the SMRD consist of 0.7 cm thick extruded scintillator slabs inserted into air gaps of the UA1 magnet yokes. The readout of each scintillator slab is provided through a single WLS fiber embedded into a serpentine shaped groove. Two Hamamatsu multi-pixel avalanche photodiodes (MPPC's) are coupled to both ends of the WLS fiber. This design allows us to achieve a high MIP detection efficiency of greater than 99%. A light yield of 25-50 p.e./MIP, a time resolution of about 1 ns and a spatial resolution along the slab better than 10 cm were obtained for the SMRD counters.

preprint2008arXiv

Precise Measurement of pi+ -> e+ nu Branching Ratio

The PEN Collaboration is conducting a new measurement of the pi+ -> e+ nu branching ratio at the Paul Scherrer Institute, with the goal uncertainty of delta B/B(pie2)=5E-4 or lower. At present, the combined accuracy of all published pie2 decay measurements lags behind the theoretical calculation by a factor of 40. In this contribution we report on the PEN detector configuration and its performance during two development runs done in 2007 and 2008.

preprint2003arXiv

Design, Commissioning and Performance of the PIBETA Detector at PSI

We describe the design, construction and performance of the PIBETA detector built for the precise measurement of the branching ratio of pion beta decay, pi+ -> pi0 e+ nu, at the Paul Scherrer Institute. The central part of the detector is a 240-module spherical pure CsI calorimeter covering 3*pi sr solid angle. The calorimeter is supplemented with an active collimator/beam degrader system, an active segmented plastic target, a pair of low-mass cylindrical wire chambers and a 20-element cylindrical plastic scintillator hodoscope. The whole detector system is housed inside a temperature-controlled lead brick enclosure which in turn is lined with cosmic muon plastic veto counters. Commissioning and calibration data were taken during two three-month beam periods in 1999/2000 with pi+ stopping rates between 1.3*E3 pi+/s and 1.3*E6 pi+/s. We examine the timing, energy and angular detector resolution for photons, positrons and protons in the energy range of 5-150 MeV, as well as the response of the detector to cosmic muons. We illustrate the detector signatures for the assorted rare pion and muon decays and their associated backgrounds.