Researcher profile

T. Itoh

T. Itoh contributes to research discovery and scholarly infrastructure.

ResearcherAffiliation not importedOpen to collaborate

Trust snapshot

Quick read

Trust 17 - UnverifiedVerification L1Unclaimed author
4works
0followers
2topics
4close collaborators

Actions

Decide how to stay connected

Follow researcher0

Identity and collaboration

How to connect with this researcher

Claiming links this public author record to a researcher profile and unlocks direct collaboration workflows.

Log in to claim

Direct collaboration

Open a focused conversation when the fit is right

Claim this author entity first to unlock direct invitations.

Research graph

See the researcher in context

Open full explorer

Inspect adjacent work, topics, institutions and collaborators without jumping out to a separate graph page.

Building this graph slice

BZPEER is loading the nearby papers, people, topics and institutions for this page.

Published work

4 published item(s)

preprint2015arXiv

Probing astrophysically important states in $^{26}$Mg nucleus to study neutron sources for the $s$-Process

The $^{22}$Ne($α$,n)$^{25}$Mg reaction is the dominant neutron source for the slow neutron capture process ($s$-process) in massive stars and contributes, together with the $^{13}$C($α$,n)$^{16}$O, to the production of neutrons for the $s$-process in Asymptotic Giant Branch (AGB) stars. However, the reaction is endothermic and competes directly with the $^{22}$Ne($α,γ)^{26}$Mg radiative capture. The uncertainties for both reactions are large owing to the uncertainty in the level structure of $^{26}$Mg near the alpha and neutron separation energies. These uncertainties are affecting the s-process nucleosynthesis calculations in theoretical stellar models. Indirect studies in the past have been successful in determining the energies, $γ$-ray and neutron widths of the $^{26}$Mg states in the energy region of interest. But, the high Coulomb barrier hinders a direct measurement of the resonance strengths, which are determined by the $α$-widths for these states. The goal of the present experiments is to identify the critical resonance states and to precisely measure the $α$-widths by $α$ transfer techniques . Hence, the $α$-inelastic scattering and $α$-transfer measurements were performed on a solid $^{26}$Mg target and a $^{22}$Ne gas target, respectively, using the Grand Raiden Spectrometer at RCNP, Osaka, Japan. Six levels (E$_x$ = 10717 keV , 10822 keV, 10951 keV, 11085 keV, 11167 keV and 11317 keV) have been observed above the $α$-threshold in the region of interest (10.61 - 11.32 MeV). The rates are dominated in both reaction channels by the resonance contributions of the states at E$_x$ = 10951, 11167 and 11317 keV. The E$_x$ =11167 keV has the most appreciable impact on the ($α,γ$) rate and therefore plays an important role for the prediction of the neutron production in s-process environments.

preprint2008arXiv

X-Ray Spectral Variability of the Seyfert Galaxy NGC 4051 Observed with Suzaku

We report results from a Suzaku observation of the narrow-line Seyfert 1 NGC 4051. During our observation, large amplitude rapid variability is seen and the averaged 2--10 keV flux is 8.1x10^-12 erg s^-1 cm^-2, which is several times lower than the historical average. The X-ray spectrum hardens when the source flux becomes lower, confirming the trend of spectral variability known for many Seyfert 1 galaxies. The broad-band averaged spectrum and spectra in high and low flux intervals are analyzed. The spectra are first fitted with a model consisting of a power-law component, a reflection continuum originating in cold matter, a blackbody component, two zones of ionized absorber, and several Gaussian emission lines. The amount of reflection is rather large (R ~ 7, where R=1 corresponds to reflection by an infinite slab), while the equivalent width of the Fe-K line at 6.4 keV is modest (140 eV) for the averaged spectrum. We then model the overall spectra by introducing partial covering for the power-law component and reflection continuum independently. The column density for the former is 1x10^23 cm^-2, while it is fixed at 1x10^24 cm-2 for the latter. By comparing the spectra in different flux states, we identify the causes of spectral variability. (abridged)

preprint2006arXiv

Hard X-ray Detector (HXD) on Board Suzaku

The Hard X-ray Detector (HXD) on board Suzaku covers a wide energy range from 10 keV to 600 keV by combination of silicon PIN diodes and GSO scintillators. The HXD is designed to achieve an extremely low in-orbit back ground based on a combination of new techniques, including the concept of well-type active shield counter. With an effective area of 142 cm^2 at 20 keV and 273 cm2 at 150 keV, the background level at the sea level reached ~1x10^{-5} cts s^{-1} cm^{-2} keV^{-1} at 30 keV for the PI N diodes, and ~2x10^{-5} cts s^{-1} cm^{-2} keV^{-1} at 100 keV, and ~7x10^{-6} cts s^{-1} cm^{-2} keV^{-1} at 200 keV for the phoswich counter. Tight active shielding of the HXD results in a large array of guard counters surrounding the main detector parts. These anti-coincidence counters, made of ~4 cm thick BGO crystals, have a large effective area for sub-MeV to MeV gamma-rays. They work as an excellent gamma-ray burst monitor with limited angular resolution (~5 degree). The on-board signal-processing system and the data transmitted to the ground are also described.

preprint2006arXiv

In-Orbit Performance of the Hard X-ray Detector on board Suzaku

The in-orbit performance and calibration of the Hard X-ray Detector (HXD) on board the X-ray astronomy satellite Suzaku are described. Its basic performances, including a wide energy bandpass of 10-600 keV, energy resolutions of ~4 keV (FWHM) at 40 keV and ~11% at 511 keV, and a high background rejection efficiency, have been confirmed by extensive in-orbit calibrations. The long-term gains of PIN-Si diodes have been stable within 1% for half a year, and those of scintillators have decreased by 5-20%. The residual non-X-ray background of the HXD is the lowest among past non-imaging hard X-ray instruments in energy ranges of 15-70 and 150-500 keV. We provide accurate calibrations of energy responses, angular responses, timing accuracy of the HXD, and relative normalizations to the X-ray CCD cameras using multiple observations of the Crab Nebula.