Researcher profile

T. Cecil

T. Cecil contributes to research discovery and scholarly infrastructure.

ResearcherAffiliation not importedOpen to collaborate

Trust snapshot

Quick read

Trust 13 - UnverifiedVerification L1Unclaimed author
2works
0followers
4topics
4close collaborators

Actions

Decide how to stay connected

Follow researcher0

Identity and collaboration

How to connect with this researcher

Claiming links this public author record to a researcher profile and unlocks direct collaboration workflows.

Log in to claim

Direct collaboration

Open a focused conversation when the fit is right

Claim this author entity first to unlock direct invitations.

Research graph

See the researcher in context

Open full explorer

Inspect adjacent work, topics, institutions and collaborators without jumping out to a separate graph page.

Building this graph slice

BZPEER is loading the nearby papers, people, topics and institutions for this page.

Published work

2 published item(s)

preprint2022arXiv

Strategies for reducing frequency scatter in large arrays of superconducting resonators

Superconducting resonators are now found in a broad range of applications that require high-fidelity measurement of low-energy signals. A common feature across almost all of these applications is the need for increased numbers of resonators to further improve sensitivity, and the ability to read out large numbers of resonators without the need for additional cryogenic complexity is a primary motivation. One of the major limitations of current resonator arrays is the observed scatter in the resonator frequencies when compared to the initial design. Here we present recent progress toward identifying one of the dominant underlying causes of resonator scatter, inductor line width fluctuation. We designed and fabricated an array of lumped-element resonators with inductor line width changing from 1.8um to 2.2um in step of 0.1um defined with electron-beam lithography to probe and quantify the systematic variation of resonance frequency across a 6-inch wafer. The resonators showed a linear frequency shift of 20MHz (140FWHM) and 30MHz (214FWHM), respectively, as they are connected to two different capacitors. This linear relationship matches our theoretical prediction. The widely used MLA photon lithography facility for MKID fabrication has a resolution on the order of 600nm, which could cause frequency fluctuation on the order of 100MHz or 710FWHM.

preprint2021arXiv

SPT-SLIM: A Line Intensity Mapping Pathfinder for the South Pole Telescope

The South Pole Telescope Summertime Line Intensity Mapper (SPT-SLIM) is a pathfinder experiment that will demonstrate the use of on-chip filter-bank spectrometers for mm-wave line intensity mapping (LIM). The SPT-SLIM focal plane consists of 18 dual-polarization R=300 filter-bank spectrometers covering 120-180 GHz, coupled to aluminum kinetic inductance detectors. A compact cryostat holds the detectors at 100 mK and performs observations without removing the SPT-3G receiver. SPT-SLIM will be deployed to the 10-m South Pole Telescope for observations during the 2023-24 austral summer. We discuss the overall instrument design, expected detector performance and sensitivity to the LIM signal from CO at 0.5 < z < 2. The technology and observational techniques demonstrated by SPT-SLIM will enable next-generation LIM experiments that constrain cosmology beyond the redshift reach of galaxy surveys.