Researcher profile

T. C. Petersen

T. C. Petersen contributes to research discovery and scholarly infrastructure.

ResearcherAffiliation not importedOpen to collaborate

Trust snapshot

Quick read

Trust 19 - UnverifiedVerification L1Unclaimed author
5works
0followers
6topics
4close collaborators

Actions

Decide how to stay connected

Follow researcher0

Identity and collaboration

How to connect with this researcher

Claiming links this public author record to a researcher profile and unlocks direct collaboration workflows.

Log in to claim

Direct collaboration

Open a focused conversation when the fit is right

Claim this author entity first to unlock direct invitations.

Research graph

See the researcher in context

Open full explorer

Inspect adjacent work, topics, institutions and collaborators without jumping out to a separate graph page.

Building this graph slice

BZPEER is loading the nearby papers, people, topics and institutions for this page.

Published work

5 published item(s)

preprint2021arXiv

Factors limiting quantitative phase retrieval in atomic-resolution differential phase contrast scanning transmission electron microscopy using a segmented detector

Quantitative differential phase contrast imaging of materials in atomic-resolution scanning transmission electron microscopy using segmented detectors is limited by various factors, including coherent and incoherent aberrations, detector positioning and uniformity, and scan-distortion. By comparing experimental case studies of monolayer and few-layer graphene with image simulations, we explore which parameters require the most precise characterisation for reliable and quantitative interpretation of the reconstructed phases. Coherent and incoherent lens aberrations are found to have the most significant impact. For images over a large field of view, the impact of noise and non-periodic boundary conditions are appreciable, but in this case study have less of an impact than artefacts introduced by beam deflections coupling to beam scanning (imperfect tilt-shift purity).

preprint2020arXiv

Suppressing dynamical diffraction artefacts in differential phase contrast scanning transmission electron microscopy of long-range electromagnetic fields via precession

In differential phase contrast scanning transmission electron microscopy (DPC-STEM), variability in dynamical diffraction resulting from changes in sample thickness and local crystal orientation (due to sample bending) can produce contrast comparable to that arising from the long-range electromagnetic fields probed by this technique. Through simulation we explore the scale of these dynamical diffraction artefacts and introduce a metric for the magnitude of their confounding contribution to the contrast. We show that precession over an angular range of a few milliradian can suppress this confounding contrast by one-to-two orders of magnitude. Our exploration centres around a case study of GaAs near the [011] zone-axis orientation using a probe-forming aperture semiangle on the order of 0.1 mrad at 300 keV, but the trends found and methodology used are expected to apply more generally.

preprint2019arXiv

Combined sensitivity to the neutrino mass ordering with JUNO, the IceCube Upgrade, and PINGU

The ordering of the neutrino mass eigenstates is one of the fundamental open questions in neutrino physics. While current-generation neutrino oscillation experiments are able to produce moderate indications on this ordering, upcoming experiments of the next generation aim to provide conclusive evidence. In this paper we study the combined performance of the two future multi-purpose neutrino oscillation experiments JUNO and the IceCube Upgrade, which employ two very distinct and complementary routes towards the neutrino mass ordering. The approach pursued by the $20\,\mathrm{kt}$ medium-baseline reactor neutrino experiment JUNO consists of a careful investigation of the energy spectrum of oscillated $\barν_e$ produced by ten nuclear reactor cores. The IceCube Upgrade, on the other hand, which consists of seven additional densely instrumented strings deployed in the center of IceCube DeepCore, will observe large numbers of atmospheric neutrinos that have undergone oscillations affected by Earth matter. In a joint fit with both approaches, tension occurs between their preferred mass-squared differences $ Δm_{31}^{2}=m_{3}^{2}-m_{1}^{2} $ within the wrong mass ordering. In the case of JUNO and the IceCube Upgrade, this allows to exclude the wrong ordering at $>5σ$ on a timescale of 3--7 years --- even under circumstances that are unfavorable to the experiments' individual sensitivities. For PINGU, a 26-string detector array designed as a potential low-energy extension to IceCube, the inverted ordering could be excluded within 1.5 years (3 years for the normal ordering) in a joint analysis.

preprint2019arXiv

Design and Performance of the first IceAct Demonstrator at the South Pole

In this paper we describe the first results of a compact imaging air-Cherenkov telescope, IceAct, operating in coincidence with the IceCube Neutrino Observatory (IceCube) at the geographic South Pole. An array of IceAct telescopes (referred to as the IceAct project) is under consideration as part of the IceCube-Gen2 extension to IceCube. Surface detectors in general will be a powerful tool in IceCube-Gen2 for distinguishing astrophysical neutrinos from the dominant backgrounds of cosmic-ray induced atmospheric muons and neutrinos: the IceTop array is already in place as part of IceCube, but has a high energy threshold. Although the duty cycle will be lower for the IceAct telescopes than the present IceTop tanks, the IceAct telescopes may prove to be more effective at lowering the detection threshold for air showers. Additionally, small imaging air-Cherenkov telescopes in combination with IceTop, the deep IceCube detector or other future detector systems might improve measurements of the composition of the cosmic ray energy spectrum. In this paper we present measurements of a first 7-pixel imaging air Cherenkov telescope demonstrator, proving the capability of this technology to measure air showers at the South Pole in coincidence with IceTop and the deep IceCube detector.

preprint2019arXiv

Sharp images from diffuse beams: factorisation of the discrete delta function

Discrete delta functions define the limits of attainable spatial resolution for all imaging systems. Here we construct broad, multi-dimensional discrete functions that replicate closely the action of a Dirac delta function under aperiodic convolution. These arrays spread the energy of a sharp probe beam to simultaneously sample multiple points across the volume of a large object, without losing image sharpness. A diffuse point-spread function applied in any imaging system can reveal the underlying structure of objects less intrusively and with equal or better signal-to-noise ratio. These multi-dimensional arrays are related to previously known, but relatively rarely employed, one-dimensional integer Huffman sequences. Practical point-spread functions can now be made sufficiently large to span the size of the object under measure. Such large arrays can be applied to ghost imaging, which has demonstrated potential to greatly improve signal-to-noise ratios and reduce the total dose required for tomographic imaging. The discrete arrays built here parallel the continuum self-adjoint or Hermitian functions that underpin wave theory and quantum mechanics.