Researcher profile

Susanna Guiducci

Susanna Guiducci contributes to research discovery and scholarly infrastructure.

ResearcherAffiliation not importedOpen to collaborate

Trust snapshot

Quick read

Trust 19 - UnverifiedVerification L1Unclaimed author
5works
0followers
1topics
4close collaborators

Actions

Decide how to stay connected

Follow researcher0

Identity and collaboration

How to connect with this researcher

Claiming links this public author record to a researcher profile and unlocks direct collaboration workflows.

Log in to claim

Direct collaboration

Open a focused conversation when the fit is right

Claim this author entity first to unlock direct invitations.

Research graph

See the researcher in context

Open full explorer

Inspect adjacent work, topics, institutions and collaborators without jumping out to a separate graph page.

Building this graph slice

BZPEER is loading the nearby papers, people, topics and institutions for this page.

Published work

5 published item(s)

preprint2022arXiv

SHERPAD: test of Slow high-efficiency extraction of Positrons from a Ring At DAFNE

The idea of using fixed-target annihilations of a high-energy positron beam on a target for producing a new, very feebly interacting particle has been exploited by the PADME experiment at LNF using the extracted beam from the LINAC in the BTF facility. Extracting the beam from a synchrotron would improve by several orders of magnitude the duty-cycle of the LINAC, thus greatly extending the physics reach of such experiments. The option of substituting or complementing the standard, slow 1/3 of integer resonant extraction technique by using coherent phenomena in a bent crystal, like the channeling has been studied by the SHERPA experiment. Both using the DAFNE main positron ring or the smaller damping ring (accumulator) as pulse extender of the LINAC have been considered. We here propose to demonstrate the feasibility of this technique performing an experiment on the DAFNE positron main ring, installing in a suitable vacuum goniometer a thin Silicon crystal, bent in the (110) direction in order to provide a ~1 mrad kick, and then simulating the extraction process with a virtual septum: instead of performing a real extraction, the crossing of the gap of a septum magnet is simulated by detecting positrons at its position (at phase advance close to 1/4) by means of a Silicon pixel detector inserted in the ring, in a secondary vacuum of a Roman pot.

preprint2014arXiv

Investigation into electron cloud effects in the International Linear Collider positron damping ring

We report modeling results for electron cloud buildup and instability in the International Linear Collider positron damping ring. Updated optics, wiggler magnets, and vacuum chamber designs have recently been developed for the 5 GeV, 3.2-km racetrack layout. An analysis of the synchrotron radiation profile around the ring has been performed, including the effects of diffuse and specular photon scattering on the interior surfaces of the vacuum chamber. The results provide input to the cloud buildup simulations for the various magnetic field regions of the ring. The modeled cloud densities thus obtained are used in the instability threshold calculations. We conclude that the mitigation techniques employed in this model will suffice to allow operation of the damping ring at the design operational specifications.

preprint2013arXiv

The International Linear Collider Technical Design Report - Volume 3.I: Accelerator R&D in the Technical Design Phase

The International Linear Collider Technical Design Report (TDR) describes in four volumes the physics case and the design of a 500 GeV centre-of-mass energy linear electron-positron collider based on superconducting radio-frequency technology using Niobium cavities as the accelerating structures. The accelerator can be extended to 1 TeV and also run as a Higgs factory at around 250 GeV and on the Z0 pole. A comprehensive value estimate of the accelerator is give, together with associated uncertainties. It is shown that no significant technical issues remain to be solved. Once a site is selected and the necessary site-dependent engineering is carried out, construction can begin immediately. The TDR also gives baseline documentation for two high-performance detectors that can share the ILC luminosity by being moved into and out of the beam line in a "push-pull" configuration. These detectors, ILD and SiD, are described in detail. They form the basis for a world-class experimental programme that promises to increase significantly our understanding of the fundamental processes that govern the evolution of the Universe.

preprint2013arXiv

The International Linear Collider Technical Design Report - Volume 3.II: Accelerator Baseline Design

The International Linear Collider Technical Design Report (TDR) describes in four volumes the physics case and the design of a 500 GeV centre-of-mass energy linear electron-positron collider based on superconducting radio-frequency technology using Niobium cavities as the accelerating structures. The accelerator can be extended to 1 TeV and also run as a Higgs factory at around 250 GeV and on the Z0 pole. A comprehensive value estimate of the accelerator is give, together with associated uncertainties. It is shown that no significant technical issues remain to be solved. Once a site is selected and the necessary site-dependent engineering is carried out, construction can begin immediately. The TDR also gives baseline documentation for two high-performance detectors that can share the ILC luminosity by being moved into and out of the beam line in a "push-pull" configuration. These detectors, ILD and SiD, are described in detail. They form the basis for a world-class experimental programme that promises to increase significantly our understanding of the fundamental processes that govern the evolution of the Universe.

preprint2012arXiv

Mitigation and control of instabilities in DAFNE positron ring

The positron beam in the DAFNE e+/e- collider has always been suffering from strong e-cloud instabilities. In order to cope with them, several approaches have been adopted along the years: flexible and powerful bunch-by-bunch feedback systems, solenoids around the straight sections of the vacuum chamber and, in the last runs, e-cloud clearing electrodes inside the bending and wiggler magnets. Of course classic diagnostics tools have been used to evaluate the effectiveness of the adopted measures and the correct setup of the devices, in order to acquire total beam and bunch-by-bunch currents, to plot in real time synchrotron and betatron instabilities, to verify the vertical beam size enlargement in collision and out of collision. Besides, to evaluate the efficacy of the solenoids and of the clearing electrodes versus the instability speed, the more powerful tools have been the special diagnostics routines making use of the bunch-by-bunch feedback systems to quickly compute the growth rate instabilities and the bunch-by-bunch tune spread in different beam conditions.