Source author record

Stuart Lowe

Stuart Lowe appears in the imported research catalog. Authorship, coauthor and topic links are available while profile ownership is still unclaimed.

ResearcherUnclaimed source record

Catalog footprint

What is connected

3works
2topics
4close collaborators

Actions

Connect this record

Log in to claim

Research graph

See the researcher in context

Open full explorer

Inspect adjacent papers, topics, institutions and collaborators without losing the researcher page.

Building this map preview

BZPEER is loading the nearby papers, people, topics and institutions for this page.

Published work

3 published item(s)

preprint2011arXiv

Sunyaev Zel'dovich observations of a statistically complete sample of galaxy clusters with OCRA-p

We present 30 GHz Sunyaev Zel'dovich observations of a statistically complete sample of galaxy clusters with OCRA-p. The clusters are the 18 most X-ray luminous clusters at z > 0.2 in the ROSAT Brightest Cluster Sample. We correct for contaminant radio sources via supplementary observations with the Green Bank Telescope, also at 30 GHz, and remove a cluster that is contaminated by an unresolved X-ray source. All 17 remaining clusters have central SZ effects with Comptonisation parameter y_0 exceeding 1.9x10^-4, and 13 are detected at significance > 3 sigma. We use our data to examine scalings between y_0 and X-ray temperature, X-ray luminosity, and the X-ray mass proxy Y_X, and find good agreement with predictions from self-similar models of cluster formation, with an intrinsic scatter in y_0 of about 25%. We also comment on the success of the observations in the face of the contaminant source population, and the implications for upcoming cm-wave surveys.

preprint2010arXiv

Planck-LFI radiometers tuning

"This paper is part of the Prelaunch status LFI papers published on JINST: http://www.iop.org/EJ/journal/-page=extra.proc5/jinst" This paper describes the Planck Low Frequency Instrument tuning activities performed through the ground test campaigns, from Unit to Satellite Levels. Tuning is key to achieve the best possible instrument performance and tuning parameters strongly depend on thermal and electrical conditions. For this reason tuning has been repeated several times during ground tests and it has been repeated in flight before starting nominal operations. The paper discusses the tuning philosophy, the activities and the obtained results, highlighting developments and changes occurred during test campaigns. The paper concludes with an overview of tuning performed during the satellite cryogenic test campaign (Summer 2008) and of the plans for the just started in-flight calibration.

preprint2010arXiv

Planck-LFI: Design and Performance of the 4 Kelvin Reference Load Unit

The LFI radiometers use a pseudo-correlation design where the signal from the sky is continuously compared with a stable reference signal, provided by a cryogenic reference load system. The reference unit is composed by small pyramidal horns, one for each radiometer, 22 in total, facing small absorbing targets, made of a commercial resin ECCOSORB CR (TM), cooled to approximately 4.5 K. Horns and targets are separated by a small gap to allow thermal decoupling. Target and horn design is optimized for each of the LFI bands, centered at 70, 44 and 30 GHz. Pyramidal horns are either machined inside the radiometer 20K module or connected via external electro-formed bended waveguides. The requirement of high stability of the reference signal imposed a careful design for the radiometric and thermal properties of the loads. Materials used for the manufacturing have been characterized for thermal, RF and mechanical properties. We describe in this paper the design and the performance of the reference system.