Simulation of ion track ranges in uranium oxide
Direct comparisons between statistically sound simulations of ion-tracks and published experimental measurements of range densities of iodine implants in uranium dioxide have been made with implant energies in the range of 100-800 keV. Our simulations are conducted with REED-MD (Rare Event Enhanced Domain-following Molecular Dynamics) in order to account for the materials structure in both single crystalline and polycrystalline experimental samples. We find near-perfect agreement between REED-MD results and experiments for polycrystalline target materials.