Researcher profile

Steve R. Furlanetto

Steve R. Furlanetto contributes to research discovery and scholarly infrastructure.

ResearcherAffiliation not importedOpen to collaborate

Trust snapshot

Quick read

Trust 17 - UnverifiedVerification L1Unclaimed author
4works
0followers
2topics
4close collaborators

Actions

Decide how to stay connected

Follow researcher0

Identity and collaboration

How to connect with this researcher

Claiming links this public author record to a researcher profile and unlocks direct collaboration workflows.

Log in to claim

Direct collaboration

Open a focused conversation when the fit is right

Claim this author entity first to unlock direct invitations.

Research graph

See the researcher in context

Open full explorer

Inspect adjacent work, topics, institutions and collaborators without jumping out to a separate graph page.

Building this graph slice

BZPEER is loading the nearby papers, people, topics and institutions for this page.

Published work

4 published item(s)

preprint2020arXiv

Absolute Calibration Strategies for the Hydrogen Epoch of Reionization Array and Their Impact on the 21 cm Power Spectrum

We discuss absolute calibration strategies for Phase I of the Hydrogen Epoch of Reionization Array (HERA), which aims to measure the cosmological 21 cm signal from the Epoch of Reionization (EoR). HERA is a drift-scan array with a 10 degree wide field of view, meaning bright, well-characterized point source transits are scarce. This, combined with HERA's redundant sampling of the uv plane and the modest angular resolution of the Phase I instrument, make traditional sky-based and self-calibration techniques difficult to implement with high dynamic range. Nonetheless, in this work we demonstrate calibration for HERA using point source catalogues and electromagnetic simulations of its primary beam. We show that unmodeled diffuse flux and instrumental contaminants can corrupt the gain solutions, and present a gain smoothing approach for mitigating their impact on the 21 cm power spectrum. We also demonstrate a hybrid sky and redundant calibration scheme and compare it to pure sky-based calibration, showing only a marginal improvement to the gain solutions at intermediate delay scales. Our work suggests that the HERA Phase I system can be well-calibrated for a foreground-avoidance power spectrum estimator by applying direction-independent gains with a small set of degrees of freedom across the frequency and time axes.

preprint2020arXiv

Foreground modelling via Gaussian process regression: an application to HERA data

The key challenge in the observation of the redshifted 21-cm signal from cosmic reionization is its separation from the much brighter foreground emission. Such separation relies on the different spectral properties of the two components, although, in real life, the foreground intrinsic spectrum is often corrupted by the instrumental response, inducing systematic effects that can further jeopardize the measurement of the 21-cm signal. In this paper, we use Gaussian Process Regression to model both foreground emission and instrumental systematics in $\sim 2$ hours of data from the Hydrogen Epoch of Reionization Array. We find that a simple co-variance model with three components matches the data well, giving a residual power spectrum with white noise properties. These consist of an "intrinsic" and instrumentally corrupted component with a coherence-scale of 20 MHz and 2.4 MHz respectively (dominating the line of sight power spectrum over scales $k_{\parallel} \le 0.2$ h cMpc$^{-1}$) and a baseline dependent periodic signal with a period of $\sim 1$ MHz (dominating over $k_{\parallel} \sim 0.4 - 0.8$h cMpc$^{-1}$) which should be distinguishable from the 21-cm EoR signal whose typical coherence-scales is $\sim 0.8$ MHz.

preprint2020arXiv

Measuring HERA's primary beam in-situ: methodology and first results

The central challenge in 21~cm cosmology is isolating the cosmological signal from bright foregrounds. Many separation techniques rely on the accurate knowledge of the sky and the instrumental response, including the antenna primary beam. For drift-scan telescopes such as the Hydrogen Epoch of Reionization Array \citep[HERA, ][]{DeBoer2017} that do not move, primary beam characterization is particularly challenging because standard beam-calibration routines do not apply \citep{Cornwell2005} and current techniques require accurate source catalogs at the telescope resolution. We present an extension of the method from \citet{Pober2012} where they use beam symmetries to create a network of overlapping source tracks that break the degeneracy between source flux density and beam response and allow their simultaneous estimation. We fit the beam response of our instrument using early HERA observations and find that our results agree well with electromagnetic simulations down to a -20~dB level in power relative to peak gain for sources with high signal-to-noise ratio. In addition, we construct a source catalog with 90 sources down to a flux density of 1.4~Jy at 151~MHz.

preprint2019arXiv

Mitigating Internal Instrument Coupling II: A Method Demonstration with the Hydrogen Epoch of Reionization Array

We present a study of internal reflection and cross coupling systematics in Phase I of the Hydrogen Epoch of Reionization Array (HERA). In a companion paper, we outlined the mathematical formalism for such systematics and presented algorithms for modeling and removing them from the data. In this work, we apply these techniques to data from HERA&#39;s first observing season as a method demonstration. The data show evidence for systematics that, without removal, would hinder a detection of the 21 cm power spectrum for the targeted EoR line-of-sight modes in the range 0.2 < k_parallel < 0.5\ h^-1 Mpc. After systematic removal, we find we can recover these modes in the power spectrum down to the integrated noise-floor of a nightly observation, achieving a dynamic range in the EoR window of 10^-6 in power (mK^2 units) with respect to the bright galactic foreground signal. In the absence of other systematics and assuming the systematic suppression demonstrated here continues to lower noise levels, our results suggest that fully-integrated HERA Phase I may have the capacity to set competitive upper limits on the 21 cm power spectrum. For future observing seasons, HERA will have upgraded analog and digital hardware to better control these systematics in the field.