Source author record

Steve Lamoreaux

Steve Lamoreaux appears in the imported research catalog. Authorship, coauthor and topic links are available while profile ownership is still unclaimed.

ResearcherUnclaimed source record

Catalog footprint

What is connected

2works
2topics
4close collaborators

Actions

Connect this record

Log in to claim

Research graph

See the researcher in context

Open full explorer

Inspect adjacent papers, topics, institutions and collaborators without losing the researcher page.

Building this map preview

BZPEER is loading the nearby papers, people, topics and institutions for this page.

Published work

2 published item(s)

preprint2013arXiv

Casimir probe based upon metallized high Q SiN nanomembrane resonator

We present the instrumentation and measurement scheme of a new Casimir force probe that bridges Casimir force measurements at microscale and macroscale. A metallized high Q silicon nitride nanomembrane resonator is employed as a sensitive force probe. The high tensile stress present in the nanomembrane not only enhances the quality factor but also maintains high flatness over large area serving as the bottom electrode in a sphere-plane configuration. A fiber interferometer is used to readout the oscillation of the nanomembrane and a phase-locked loop scheme is applied to track the change of the resonance frequency. Because of the high quality factor of the nanomembrane and the high stability of the setup, a frequency resolution down to $2\times10^{-9}$ and a corresponding force gradient resolution of 3 $μ$N/m is achieved. Besides sensitive measurement of Casimir force, our measurement technique simultaneously offers Kelvin probe measurement capability that allows in situ imaging of the surface potentials.

preprint2012arXiv

Casimir Force and In Situ Surface Potential Measurements on Nanomembranes

We present Casimir force measurements in a sphere-plate configuration that consists of a high quality nanomembrane resonator and a millimeter sized gold coated sphere. The nanomembrane is fabricated from stoichiometric silicon nitride metallized with gold. A Kelvin probe method is used in situ to image the surface potentials to minimize the distance-dependent residual force. Resonance-enhanced frequency-domain measurements of the nanomembrane motion allow for very high resolution measurements of the Casimir force gradient (down to a force gradient sensitivity of 3 uN/m). Using this technique, the Casimir force in the range of 100 nm to 2 um is accurately measured. Experimental data thus obtained indicate that the device system in the measured range is best described with the Drude model.