Researcher profile

Stephen D. Wolters

Stephen D. Wolters contributes to research discovery and scholarly infrastructure.

ResearcherAffiliation not importedOpen to collaborate

Trust snapshot

Quick read

Trust 17 - UnverifiedVerification L1Unclaimed author
4works
0followers
3topics
4close collaborators

Actions

Decide how to stay connected

Follow researcher0

Identity and collaboration

How to connect with this researcher

Claiming links this public author record to a researcher profile and unlocks direct collaboration workflows.

Log in to claim

Direct collaboration

Open a focused conversation when the fit is right

Claim this author entity first to unlock direct invitations.

Research graph

See the researcher in context

Open full explorer

Inspect adjacent work, topics, institutions and collaborators without jumping out to a separate graph page.

Building this graph slice

BZPEER is loading the nearby papers, people, topics and institutions for this page.

Published work

4 published item(s)

preprint2013arXiv

WatSen: Design and testing of a prototype mid-IR spectrometer and microscope package for Mars exploration

We have designed and built a compact breadboard prototype instrument called WatSen: a combined ATR mid-IR spectrometer, fixed-focus microscope, and humidity sensor. The instrument package is enclosed in a rugged cylindrical casing only 26mm in diameter. The functionality, reliability and performance of the instrument was tested in an environment chamber set up to resemble martian surface conditions. The effective wavelength range of the spectrometer is 6.2 - 10.3 micron with a resolution delta-wavelength/wavelength = 0.015. This allows detection of silicates and carbonates, including an indication of the presence of water (ice). Spectra of clusters of grains < 1mm across were acquired that are comparable with spectra of the same material obtained using a commercial system. The microscope focuses through the diamond ATR crystal. Colour images of the grains being spectroscopically analysed are obtainable with a resolution of ~ 20 micron.

preprint2011arXiv

Measurement requirements for a near-Earth asteroid impact mitigation demonstration mission

A concept for an Impact Mitigation Preparation Mission, called Don Quijote, is to send two spacecraft to a Near-Earth Asteroid (NEA): an Orbiter and an Impactor. The Impactor collides with the asteroid while the Orbiter measures the resulting change in the asteroid&#39;s orbit, by means of a Radio Science Experiment (RSE) carried out before and after impact. Three parallel Phase A studies on Don Quijote were carried out for the European Space Agency: the research presented here reflects outcomes of the study by QinetiQ. We discuss the mission objectives with regards to the prioritisation of payload instruments, with emphasis on the interpretation of the impact. The Radio Science Experiment is described and it is examined how solar radiation pressure may increase the uncertainty in measuring the orbit of the target asteroid. It is determined that to measure the change in orbit accurately a thermal IR spectrometer is mandatory, to measure the Yarkovsky effect. The advantages of having a laser altimeter are discussed. The advantages of a dedicated wide-angle impact camera are discussed and the field-of-view is initially sized through a simple model of the impact.

preprint2011arXiv

Physical characterisation of low delta-V asteroid (175706) 1996 FG3

Asteroid (175706) 1996 FG3 is a binary asteroid and the baseline target for the proposed MarcoPolo-R sample-return mission. We present thermal IR photometry obtained with the ESO VLT+VISIR together with optical photometry obtained with the ESO NTT+EFOSC2 . An absolute visual magnitude H_V = 17.833 \pm 0.024 and phase parameter G = -0.041 \pm 0.005 is derived. The Near-Earth Asteroid Thermal Model (NEATM) has been fitted to the measured fluxes to derive a geometric visual albedo p_v = 0.046 \pm 0.014, effective diameter at the observed aspect D_eff = 1.68 \pm 0.25 km, and beaming parameter η = 1.15 for phase angle α = 11.7°. The Advanced Thermophysical Model (ATPM) has been fitted to the measured fluxes to derive a more accurate effective diameter D_eff = 1.71 \pm 0.07 km and albedo p_v = 0.044 \pm 0.004. Based on the ATPM results, assuming the same albedo for primary and secondary, we derive a primary mean spherical diameter D_p = (1.69 +0.18/-0.12) km, secondary diameter D_s = 0.51 \pm 0.03 km, and a secondary orbital semi-major axis a = (2.8 +1.7/-0.7) km. A low surface thermal inertia Γ = 120 \pm 50 J m^-2 s^-1/2 K^-1 was also derived, suggesting a dusty surface and raising questions as to the binary formation mechanism of this asteroid. These physical properties are used to predict a Yarkovsky drift in semi-major axis of (-60 +31/-45) m yr-1.

preprint2009arXiv

Investigation of Systematic Bias in Radiometric Diameter Determination of Near-Earth Asteroids: the Night Emission Simulated Thermal Model (NESTM)

The Near-Earth Asteroid Thermal Model (NEATM, Harris, 1998) has proven to be a reliable simple thermal model for radiometric diameter determination. However NEATM assumes zero thermal emission on the night side of an asteroid. We investigate how this assumption affects the best-fit beaming parameter, overestimates the effective diameter and underestimates the albedo at large phase angles, by testing NEATM on thermal IR fluxes generated from simulated asteroid surfaces with different thermal inertia. We compare NEATM to radar diameters and find that NEATM overestimates the diameter when the beaming parameter is fitted to multi-wavelength observations and underestimates the diameter when the default beaming parameter is used. The Night Emission Simulated Thermal Model (NESTM) is introduced. NESTM models the night side temperature as an iso-latitudinal fraction (f) of the maximum day side temperature (Maximum temperature calculated for NEATM with beaming parameter = 1). A range of f is found for different thermal parameters, which depend on the thermal inertia. NESTM diameters are compared with NEATM and radar diameters, and it is shown that NESTM may reduce the systematic bias in overestimating diameters. It is suggested that a version of the NESTM which assumes the thermal inertia = 200 S.I. units is adopted as a default model when the solar phase angle is greater than 45 degrees.