Researcher profile

Stéphane Avril

Stéphane Avril contributes to research discovery and scholarly infrastructure.

ResearcherAffiliation not importedOpen to collaborate

Trust snapshot

Quick read

Trust 21 - EmergingVerification L1Unclaimed author
8works
0followers
4topics
4close collaborators

Actions

Decide how to stay connected

Follow researcher0

Identity and collaboration

How to connect with this researcher

Claiming links this public author record to a researcher profile and unlocks direct collaboration workflows.

Log in to claim

Direct collaboration

Open a focused conversation when the fit is right

Claim this author entity first to unlock direct invitations.

Research graph

See the researcher in context

Open full explorer

Inspect adjacent work, topics, institutions and collaborators without jumping out to a separate graph page.

Building this graph slice

BZPEER is loading the nearby papers, people, topics and institutions for this page.

Published work

8 published item(s)

preprint2023arXiv

Evaluation of image registration for measuring deformation fields in soft tissue mechanics

High-fidelity biomechanical models usually involve the mechanical characterization of biological tissues using experimental methods based on optical measurements. In most experiments, strains are evaluated based on displacements of a few markers and represents an average within the region of interest (ROI). Full-field measurements may improve description of non-homogeneous materials such as soft tissues. The approach based on non-rigid Image Registration is proposed and compared with standard Digital Image Correlation (DIC) on a set of samples, including (i) complex heterogeneous deformations with sub-pixel displacement, (ii) a typical uniaxial tension test of aorta, and (iii) an indentation test on skin. The possibility to extend the ROI to the whole sample and the exploitation of a natural tissue pattern represents the main assets of the proposed method whereas the results show similar accuracy as standard DIC when analysing sub-pixel deformations. Therefore, displacement and strain fields measurement based on Image Registration is very promising to characterize heterogeneous specimens with irregular shapes and/or small dimensions, which are typical features of soft biological tissues.

preprint2023arXiv

Patient-specific Finite Element Modeling of Aneurysmal dilatation after chronic type B aortic dissection

Progressive aneurysmal dilatation is a well-recognized complication in patients with chronic type B aortic dissection (cTBAD), which may lead to a delayed rupture and create a life-threatening condition. However, our understanding of such aortic expansion in cTBAD remains weak. In the present paper, we propose to use numerical simulations to study the role of growth and remodeling (G\&R) in aneurysmal dilatation after cTBAD. We set up a 3D finite-element model of G\&R for aortic dissection within an open-source code. Constitutive equations, momentum balance equations, and equations related to the mechanobiology of the artery were formulated based on the homogenized constrained mixture theory. The model was first applied to idealized aortic geometries with cylindrical and toric shapes to demonstrate its feasibility and efficiency. The model was then applied to a patient-specific aortic segment to show its potential in more relevant and complex patient-specific clinical applications. It was found that the G\&R tends to naturally trigger the aneurysmal dilatation after dissection, in order to restore its tensional equilibrium. Our results indicated that the value of the gain parameter, related to collagen G\&R, plays an important role in the stability of aortic expansion after cTBAD. A small gain parameter will induce an excessive aneurysmal degeneration whilst a large gain parameter helps to recover a stabilized state of the artery after dissection. Finally, it was found that other mechanobiology-related parameters, such as the circumferential length of the dissection, as well as the pressure in the false lumen, may also be determinant for the stability of aneurysmal dilatation after cTBAD. Both a wide tear and an elevated false lumen pressure favor an unstable development of aortic expansion after cTBAD. As future work, the present model will be validated through predictions of aneurysmal dilatation in patient-specific clinical cases, in comparison with datasets followed over a significant period of time.

preprint2021arXiv

A Fast Method of Virtual Stent Graft Deployment for Computer Assisted EVAR

In this paper we introduce a new method simulating stent graft deployment for assisting endovascular repair of abdominal aortic aneurysms. The method relies on intraoperative images coupled with mechanical models. A multi-step algorithm has been developed to increase the reliability of simulations. The first step predicts the position of the stent graft within the aorta. The second step is an axisymmetric geometric reconstruction of each individual stent. The third step minimizes the rotation of each stent around its main axis. Finally, the last step virtually deploys each stent within a deployment box extracted from the preoperative CT scan. A proof of concept is performed on a patient. The accuracy is compatible with the clinical threshold of 3 mm: the average distance between target and simulated stents is 1.73 $\pm$ 0.37 mm. Fenestrations of the stent-graft are reconstructed with a maximum error of less than 2.5 mm, which is enables a secure catheterization of secondary arteries. In summary, the method is able to assist EVAR practitioners by providing all necessary information for a fast and accurate stent graft positioning, combining intraoperative data and a mechanical model in a very low cost framework.

preprint2014arXiv

Patient-specific simulation of stent-graft deployment within an abdominal aortic aneurysm

In this study, finite element analysis is used to simulate the surgical deployment procedure of a bifurcated stent-graft on a real patient's arterial geometry. The stent-graft is modeled using realistic constitutive properties for both the stent and most importantly for the graft. The arterial geometry is obtained from pre-operative imaging exam. The obtained results are in good agreement with the post-operative imaging data. As the whole computational time was reduced to less than 2 hours, this study constitutes an essential step towards predictive planning simulations of aneurysmal endovascular surgery

preprint2013arXiv

3D Residual Stress Field in Arteries: Novel Inverse Method Based on Optical Full-field Measurements

Arterial tissue consists of multiple structurally important constituents that have individual material properties and associated stress-free configurations that evolve over time. This gives rise to residual stresses contributing to the homoeostatic state of stress in vivo as well as adaptations to perturbed loads, disease or injury. The existence of residual stresses in an intact but load-free excised arterial segment suggests compressive and tensile stresses, respectively, in the inner and outer walls. Accordingly, an artery ring springs open into a sector after a radial cut. The measurement of the opening angle is commonly used to deduce the residual stresses, which are the stresses required to close back the ring. The opening angle method provides an average estimate of circumferential residual stresses but it gives no information on local distributions through the thickness and along the axial direction. To address this lack, a new method is proposed in this article to derive maps of residual stresses using an approach based on the contour method. A piece of freshly excised tissue is carefully cut into the specimen, and the local distribution of residual strains and stresses is determined from whole-body digital image correlation measurements using an inverse approach based on a finite element model.

preprint2012arXiv

Computational comparison of the bending behavior of aortic stent-grafts

Secondary interventions after endovascular repair of abdominal aortic aneurysms are frequent because stent-graft (SG) related complications may occur (mainly endoleak and SG thrombosis). Complications have been related to insufficient SG flexibility, especially when devices are deployed in tortuous arteries. Little is known on the relationship between SG design and flexibility. Therefore, the aim of this study was to simulate numerically the bending of two manufactured SGs (Aorfix-Lombard Medical (A) and Zenith-Cook Medical Europe (Z)) using finite element analysis (FEA). Global SG behavior was studied by assessing stent spacing variation and cross-section deformation. Four criteria were defined to compare flexibility of SGs: maximal luminal reduction rate, torque required for bending, maximal membrane strains in graft and maximal Von Mises stress in stents. For angulation greater than 60\degree, values of these four criteria were lower with A-SG, compared to Z-SG. In conclusion, A-SG was more flexible than Z-SG according to FEA. A-SG may decrease the incidence of complications in the setting of tortuous aorto-iliac aneurysms. Our numerical model could be used to assess flexibility of further manufactured as well as newly designed SGs.

preprint2012arXiv

Mechanical identification of layer-specific properties of mouse carotid arteries using 3D-DIC and a hyperelastic anisotropic constitutive model

The role of mechanics is known to be of primary order in many arterial diseases; however, determining mechanical properties of arteries remains a challenge. This paper discusses the identifiability of the passive mechanical properties of a mouse carotid artery, taking into account the orientation of collagen fibres in the medial and adventitial layers. On the basis of 3D digital image correlation measurements of the surface strain during an inflation/extension test, an inverse identification method is set up. It involves a 3D finite element mechanical model of the mechanical test and an optimisation algorithm. A two-layer constitutive model derived from the Holzapfel model is used, with five and then seven parameters. The five-parameter model is successfully identified providing layer-specific fibre angles. The seven-parameter model is over parameterised, yet it is shown that additional data from a simple tension test make the identification of refined layer-specific data reliable.

preprint2011arXiv

Identification of Heterogeneous Elastic Properties in Stenosed Arteries: a Numerical Plane Strain Study

Assessing the vulnerability of atherosclerotic plaques requires an accurate knowledge of the mechanical properties of the plaque constituents. It is possible to measure displacements in vivo inside a plaque using magnetic resonance imaging. An important issue is to solve the inverse problem that consists in estimating the elastic properties inside the plaque from measured displacements. This study focuses on the identifiability of elastic parameters e.g. on the compromise between identification time and identification accuracy. An idealised plane strain. Finite Element (FE) model is used. The effects of the FE mesh, of the a priori assumptions about the constituents, of the measurement resolution and of the data noise are numerically investigated.