Researcher profile

Stefan C. M. ten Eikelder

Stefan C. M. ten Eikelder contributes to research discovery and scholarly infrastructure.

ResearcherAffiliation not importedOpen to collaborate

Trust snapshot

Quick read

Trust 11 - UnverifiedVerification L1Unclaimed author
1works
0followers
1topics
3close collaborators

Actions

Decide how to stay connected

Follow researcher0

Identity and collaboration

How to connect with this researcher

Claiming links this public author record to a researcher profile and unlocks direct collaboration workflows.

Log in to claim

Direct collaboration

Open a focused conversation when the fit is right

Claim this author entity first to unlock direct invitations.

Research graph

See the researcher in context

Open full explorer

Inspect adjacent work, topics, institutions and collaborators without jumping out to a separate graph page.

Building this graph slice

BZPEER is loading the nearby papers, people, topics and institutions for this page.

Published work

1 published item(s)

preprint2021arXiv

Adjustable robust treatment-length optimization in radiation therapy

Traditionally, optimization of radiation therapy (RT) treatment plans has been done before the initiation of RT course, using population-wide estimates for patients' response to therapy. However, recent technological advancements have enabled monitoring individual patient response during the RT course, in the form of biomarkers. Although biomarker data remains subject to substantial uncertainties, information extracted from this data may allow the RT plan to be adapted in a biologically informative way. We present a mathematical framework that optimally adapts the treatment-length of an RT plan based on the acquired mid-treatment biomarker information, while accounting for the inexact nature of this information. We formulate the adaptive treatment-length optimization problem as a 2-stage problem, wherein the information about the model parameters gathered during the first stage influences the decisions in the second stage. Using Adjustable Robust Optimization (ARO) techniques we derive explicit optimal decision rules for the stage-2 decisions and solve the optimization problem. The problem allows for multiple worst-case optimal solutions. To discriminate between these, we introduce the concept of Pareto Adjustable Robustly Optimal (PARO) solutions. In numerical experiments using lung cancer patient data, the ARO method is benchmarked against several other static and adaptive methods. In case of exact biomarker information, there is sufficient space to adapt, and numerical results show that taking into account both robustness and adaptability is not necessary. In case of inexact biomarker information, accounting for adaptability and inexactness of biomarker information is particularly beneficial when robustness (w.r.t. organ-at-risk (OAR) constraint violations) is of high importance. If minor OAR violations are allowed, a nominal folding horizon approach is a good performing alternative.