Researcher profile

SeungHoon Yoo

SeungHoon Yoo contributes to research discovery and scholarly infrastructure.

ResearcherAffiliation not importedOpen to collaborate

Trust snapshot

Quick read

Trust 13 - Baseline
2works
0followers
1topics
4close collaborators

Actions

Decide how to stay connected

Follow researcher0

Research graph

See the researcher in context

Open full explorer

Inspect adjacent work, topics, institutions and collaborators without jumping out to a separate graph page.

Building this graph slice

BZPEER is loading the nearby papers, people, topics and institutions for this page.

Published work

2 published item(s)

preprint2015arXiv

A comparison study of ridge filter parameter using FLUKA and GEANT4 simulation code

We investigated the parameter optimization of ridge filter thickness using a Monte Carlo simulation for carbon ion therapy. For this study, a ridge filter was designed for the Spread-Out Bragg Peak (SOBP) by considering the relative biological effect (RBE). The thickness, height, and width of the ridge filter were designed by using the FLUKA and GEANT4 code, and we analyzed and compared the results of the physical dose distribution for the FLUKA and GEANT4 coding. The results show that the minimum width of the groove for the ridge filter should be at least 0.4cm for the appropriate biological dose. The SOBP sections are 8cm, 9cm, and 10cm, respectively, when heights are 3.5cm, 4.0cm, and 4.5cm. The height of the ridge filter is designed to be associated with the SOBP width. Also, the results for the FLUKA and GEANT4 code show that an average value of difference is 3% and a maximum error is 5%; however, its trend was similar. Therefore, the height and width of the groove for the ridge filter are used for important parameters to decide the length and plateau of SOBP.

preprint2015arXiv

Simulation study of dose enhancement in a cell due to nearby carbon and oxygen in particle radiotherapy

The aim of this study is to investigate the dose-deposition enhancement by alpha-particle irradiation in a cellular model using carbon and oxygen chemical compositions.A simulation study was performed to study dose enhancement due to carbon and oxygen for a human cell where Geant4 code used for the alpha-particle irradiation to the cellular phantom. The characteristic of dose enhancement in the nucleus and cytoplasm by the alpha-particle radiation was investigated based on concentrations of the carbon and oxygen compositions and was compared with those by gold and gadolinium.The results show that both the carbon and oxygen-induced dose enhancement was found to be more effective than those of gold and gadolinium. We found that the dose-enhancement effect was more dominant in the nucleus than in the cytoplasm if carbon or oxygen is uniformly distributed in a whole cell. In the condition that the added chemical composition was inserted only into the cytoplasm, the effect of the dose enhancement in nucleus becomes weak.We showed that high-stopping-power materials offer a more effective dose-enhancement efficacy and suggest that the carbon nanotubes and oxygenation are promising candidates for dose utilization as dose enhancement tools in particle therapy.