Source author record

Sergey Alexandrov

Sergey Alexandrov appears in the imported research catalog. Authorship, coauthor and topic links are available while profile ownership is still unclaimed.

ResearcherUnclaimed source record

Catalog footprint

What is connected

2works
1topics
4close collaborators

Actions

Connect this record

Log in to claim

Research graph

See the researcher in context

Open full explorer

Inspect adjacent papers, topics, institutions and collaborators without losing the researcher page.

Building this map preview

BZPEER is loading the nearby papers, people, topics and institutions for this page.

Published work

2 published item(s)

preprint2020arXiv

Nanosensitive optical coherence tomography to assess wound healing within the cornea

Optical Coherence Tomography (OCT) is a non-invasive depth resolved optical imaging modality, that enables high resolution, cross-sectional imaging in biological tissues and materials at clinically relevant depths. Though OCT offers high resolution imaging, the best ultra-high-resolution OCT systems are limited to imaging structural changes with a resolution of one micron on a single B-scan within very limited depth. Nanosensitive OCT (nsOCT) is a recently developed technique that is capable of providing enhanced sensitivity of OCT to structural changes. Improving the sensitivity of OCT to detect structural changes at the nanoscale level, to a depth typical for conventional OCT, could potentially improve the diagnostic capability of OCT in medical applications. In this paper, we demonstrate the capability of nsOCT to detect structural changes deep in the rat cornea following superficial corneal injury.

preprint2020arXiv

Non-invasive detection of nanoscale structural changes in cornea associated with cross-linking treatment

Corneal cross-linking (CXL) using UVA irradiation with a riboflavin photosensitizer has grown from an interesting concept to a practical clinical treatment for corneal ectatic diseases globally, such as keratoconus. To characterize the corneal structural changes, existing methods such as X-ray microscopy, transmission electron microscopy (TEM), histology and optical coherence tomography have been used. However, these methods have various drawbacks such as invasive detection, the impossibility for in vivo measurement, or limited resolution and sensitivity to structural alterations. Here, we report the application of over-sampling nano-sensitive optical coherence tomography (nsOCT) method for probing the corneal structural alterations. The results indicate that the spatial period increases slightly after 30 minutes riboflavin instillation but decreases significantly after 30 min UVA irradiation following the Dresden protocol. The proposed non-invasive method can be implemented using existing OCT system, without any additional components, for detecting nanoscale changes with the potential to assist diagnostic assessment during CXL treatment, and possibly to be a real-time monitoring tool in clinics.