Source author record

Seong Oun Hwang

Seong Oun Hwang appears in the imported research catalog. Authorship, coauthor and topic links are available while profile ownership is still unclaimed.

ResearcherUnclaimed source record

Catalog footprint

What is connected

2works
2topics
4close collaborators

Actions

Connect this record

Log in to claim

Research graph

See the researcher in context

Open full explorer

Inspect adjacent papers, topics, institutions and collaborators without losing the researcher page.

Building this map preview

BZPEER is loading the nearby papers, people, topics and institutions for this page.

Published work

2 published item(s)

preprint2020arXiv

Energy Efficient Cross Layer Time Synchronization in Cognitive Radio Networks

Time synchronization is a vital concern for any Cognitive Radio Network (CRN) to perform dynamic spectrum management. Each Cognitive Radio (CR) node has to be environment aware and self adaptive and must have the ability to switch between multiple modulation schemes and frequencies. Achieving same notion of time within these CR nodes is essential to fulfill the requirements for simultaneous quiet periods for spectrum sensing. Current application layer time synchronization protocols require multiple timestamp exchanges to estimate skew between the clocks of CRN nodes. The proposed symbol timing recovery method already estimates the skew of hardware clock at the physical layer and use it for skew correction of application layer clock of each node. The heart of application layer clock is the hardware clock and hence application layer clock skew will be same as of physical layer and can be corrected from symbol timing recovery process. So one timestamp is enough to synchronize two CRN nodes. This conserves the energy utilized by application layer protocol and makes a CRN energy efficient and can achieve time synchronization in short span.

preprint2020arXiv

Implementation of Symbol Timing Recovery for Estimation of Clock Skew

Time synchronization in any distributed network can be achieved by using application layer protocols for time correction. Time synchronization method proposed in this article uses symbol timing recovery at the physical layer to correct application layer clock. This cross layer methodology diminishes the quantity of message trades needed by application layer for time synchronization thus resulting in energy saving. Precision of skew estimate can be increased by using multiple message exchanges. Examination of the cross layer strategy including the simulation results, the experimentation outcomes and mathematical analysis demonstrates that clock skew at physical layer is same as of application layer, which is actually the skew of hardware clock within the node.