Source author record

Scott Barthelmy

Scott Barthelmy appears in the imported research catalog. Authorship, coauthor and topic links are available while profile ownership is still unclaimed.

ResearcherUnclaimed source record

Catalog footprint

What is connected

6works
3topics
4close collaborators

Actions

Connect this record

Log in to claim

Research graph

See the researcher in context

Open full explorer

Inspect adjacent papers, topics, institutions and collaborators without losing the researcher page.

Building this map preview

BZPEER is loading the nearby papers, people, topics and institutions for this page.

Published work

6 published item(s)

preprint2020arXiv

Gamma-ray Urgent Archiver for Novel Opportunities (GUANO): Swift/BAT event data dumps on demand to enable sensitive sub-threshold GRB searches

We introduce a new capability of the Neil Gehrels Swift Observatory, to provide event data from the Burst Alert Telescope (BAT) on demand in response to transients detected by other instruments. These event data are not continuously available due to the large telemetry load, but are critical to recovering weak or sub-threshold GRBs that are not triggered onboard, such as the likely counterparts to GW-detected off-axis binary neutron star mergers. We show that the availability of event data can effectively increase the rate of detections, and arcminute localizations, of GRB 170817-like bursts by >400%. We describe a spacecraft commanding pipeline purpose built to enable this science; to our knowledge the first fully autonomous extremely-low-latency commanding of a space telescope for scientific purposes. This pipeline has been successfully run in its complete form since early 2020, and has resulted in the recovery of BAT event data for >700 externally triggered events to date (GWs, neutrinos, GRBs triggered by other facilities, FRBs), now running with a success rate of ~90%. We exemplify the utility of this new capability by using the resultant data to (1) set the most sensitive (8 sigma) upper limits of $8.1\times10^{-8}$ erg cm$^{-2}$ s$^{-1}$ (14-195 keV) on prompt 1s duration short GRB-like emission within $\pm$ 15s of the unmodelled GW burst candidate S200114f, and (2) provide arcminute localizations for short GRB 200325A and other bursts. We show that using data from GUANO to localize GRBs discovered elsewhere, we can increase the net rate of arcminute localized GRBs by 10-20% per year. Along with the scientific yield of more sensitive searches for sub-threshold GRBs, the new capabilities designed for this project will enable further rapid response Target of Opportunity capabilities for Swift, and have implications for the design of future rapid-response space telescopes.

preprint2016arXiv

Imaging Analysis of the Hard X-ray Telescope ProtoEXIST2 and New Techniques for High Resolution Coded Aperture Telescopes

Wide-field (> 100 deg$^2$) hard X-ray coded-aperture telescopes with high angular resolution (< 2') will enable a wide range of time domain astrophysics. For instance, transient sources such as gamma-ray bursts can be precisely localized without assistance of secondary focusing X-ray telescopes to enable rapid followup studies. On the other hand, high angular resolution in coded-aperture imaging introduces a new challenge in handling the systematic uncertainty: average photon count per pixel is often too small to establish a proper background pattern or model the systematic uncertainty in a time scale where the model remains invariant. We introduce two new techniques to improve detection sensitivity, which are designed for, but not limited to high resolution coded-aperture system: a self-background modeling scheme which utilizes continuous scan or dithering operations, and a Poisson-statistics based probabilistic approach to evaluate the significance of source detection without subtraction in handling the background. We illustrate these new imaging analysis techniques in high resolution coded-aperture telescope using the data acquired by the wide-field hard X-ray telescope ProtoEXIST2 during the high-altitude balloon flight in Fall, 2012. We review the imaging sensitivity of ProtoEXIST2 during the flight, and demonstrate the performance of the new techniques using our balloon flight data in comparison with simulated ideal Poisson background.

preprint2013arXiv

The High Resolution X-Ray Imaging Detector Planes for the MIRAX Mission

The MIRAX X-ray observatory, the first Brazilian-led astrophysics space mission, is designed to perform an unprecedented wide-field, wide-band hard X-ray (5-200 keV) survey of Galactic X-ray transient sources. In the current configuration, MIRAX will carry a set of four coded-mask telescopes with high spatial resolution Cadmium Zinc Telluride (CZT) detector planes, each one consisting of an array of 64 closely tiled CZT pixelated detectors. Taken together, the four telescopes will have a total detection area of 959 cm^2, a large field of view (60x60 degrees FWHM), high angular resolution for this energy range (6 arcmin) and very good spectral resolution (~2 keV @ 60 keV). A stratospheric balloon-borne prototype of one of the MIRAX telescopes has been developed, tested and flown by the Harvard-Smithsonian Center for Astrophysics (CfA) as part of the ProtoEXIST program. In this paper we show results of validation and calibration tests with individual CZT detectors of the ProtoEXIST second generation experiment (P2). Each one of 64 detector units of the P2 detector plane consists of an ASIC, developed by Caltech for the NuSTAR telescope, hybridized to a CZT crystal with 0.6 mm pixel size. The performance of each detector was evaluated using radioactive sources in the laboratory. The calibration results show that the P2 detectors have average energy resolution of ~2.1 keV @ 60 keV and ~2.3 keV @ 122 keV. P2 was also successfully tested on near-space environment on a balloon flight, demonstrating the detector unit readiness for integration on a space mission telescope, as well as satisfying all MIRAX mission requirements.

preprint2013arXiv

Tiled Array of Pixelated CZT Imaging Detectors for ProtoEXIST2 and MIRAX-HXI

We have assembled a tiled array (220 cm2) of fine pixel (0.6 mm) imaging CZT detectors for a balloon borne wide-field hard X-ray telescope, ProtoEXIST2. ProtoEXIST2 is a prototype experiment for a next generation hard X-ray imager MIRAX-HXI on board Lattes, a spacecraft from the Agencia Espacial Brasilieira. MIRAX will survey the 5 to 200 keV sky of Galactic bulge, adjoining southern Galactic plane and the extragalactic sky with 6' angular resolution. This survey will open a vast discovery space in timing studies of accretion neutron stars and black holes. The ProtoEXIST2 CZT detector plane consists of 64 of 5 mm thick 2 cm x 2 cm CZT crystals tiled with a minimal gap. MIRAX will consist of 4 such detector planes, each of which will be imaged with its own coded-aperture mask. We present the packaging architecture and assembly procedure of the ProtoEXIST2 detector. On 2012, Oct 10, we conducted a successful high altitude balloon experiment of the ProtoEXIST1 and 2 telescopes, which demonstrates their technology readiness for space application. During the flight both telescopes performed as well as on the ground. We report the results of ground calibration and the initial results for the detector performance in the balloon flight.

preprint2012arXiv

The Black Hole Evolution and Space Time (BEST) Observatory

In this white paper, we discuss the concept of a next-generation X-ray mission called BEST (Black hole Evolution and Space Time). The mission concept uses a 3000 square centimeter effective area mirror (at 6 keV) to achieve unprecedented sensitivities for hard X-ray imaging spectrometry (5-70 keV) and for broadband X-ray polarimetry (2-70 keV). BEST can make substantial contributions to our understanding of the inner workings of accreting black holes, our knowledge about the fabric of extremely curved spacetime, and the evolution of supermassive black holes. BEST will allow for time resolved studies of accretion disks. With a more than seven times larger mirror area and a seven times wider bandpass than GEMS, BEST will take X-ray polarimetry to a new level: it will probe the time variability of the X-ray polarization from stellar mass and supermassive black holes, and it will measure the polarization properties in 30 independent energy bins. These capabilities will allow BEST to conduct tests of accretion disk models and the underlying spacetimes. With three times larger mirror area and ten times better angular resolution than NuSTAR, BEST will be able to make deep field observations with a more than 15 times better sensitivity than NuSTAR. The mission will be able to trace the evolution of obscured and unobscured black holes in the redshift range from zero to six, covering the most important epoch of supermassive black hole growth. The hard X-ray sensitivity of BEST will enable a deep census of non-thermal particle populations. BEST will give us insights into AGN feedback by measuring the particle luminosity injected by AGNs into the interstellar medium (ISM) of their hosts, and will map the emission from particles accelerated at large scale structure shocks. Finally, BEST has the potential to constrain the equation of state of neutron stars (NS).

preprint2011arXiv

Burst and Persistent Emission Properties during the Recent Active Episode of the Anomalous X-ray Pulsar 1E 1841-045

Swift/BAT detected the first burst from 1E 1841-045 in May 2010 with intermittent burst activity recorded through at least July 2011. Here we present Swift and Fermi/GBM observations of this burst activity and search for correlated changes to the persistent X-ray emission of the source. The T90 durations of the bursts range between 18-140 ms, comparable to other magnetar burst durations, while the energy released in each burst ranges between (0.8 - 25)E38 erg, which is in the low side of SGR bursts. We find that the bursting activity did not have a significant effect on the persistent flux level of the source. We argue that the mechanism leading to this sporadic burst activity in 1E 1841-045 might not involve large scale restructuring (either crustal or magnetospheric) as seen in other magnetar sources.