Researcher profile

Sanaa H. Mohamed

Sanaa H. Mohamed contributes to research discovery and scholarly infrastructure.

ResearcherAffiliation not importedOpen to collaborate

Trust snapshot

Quick read

Trust 19 - UnverifiedVerification L1Unclaimed author
5works
0followers
4topics
4close collaborators

Actions

Decide how to stay connected

Follow researcher0

Identity and collaboration

How to connect with this researcher

Claiming links this public author record to a researcher profile and unlocks direct collaboration workflows.

Log in to claim

Direct collaboration

Open a focused conversation when the fit is right

Claim this author entity first to unlock direct invitations.

Research graph

See the researcher in context

Open full explorer

Inspect adjacent work, topics, institutions and collaborators without jumping out to a separate graph page.

Building this graph slice

BZPEER is loading the nearby papers, people, topics and institutions for this page.

Published work

5 published item(s)

preprint2022arXiv

Energy Efficient Placement of ML-Based Services in IoT Networks

The Internet of Things (IoT) is gaining momentum in its quest to bridge the gap between the physical and the digital world. The main goal of the IoT is the creation of smart environments and self-aware things that help to facilitate a variety of services such as smart transport, climate monitoring, e-health, etc. Huge volumes of data are expected to be collected by the connected sensors/things, which in traditional cases are processed centrally by large data centers in the core network that will inevitably lead to excessive transportation power consumption as well as added latency overheads. Instead, fog computing has been proposed by researchers from industry and academia to extend the capability of the cloud right to the point where the data is collected at the sensing layer. This way, primitive tasks that can be hosted in IoT sensors do not need to be sent all the way to the cloud for processing. In this paper we propose energy efficient embedding of machine learning (ML) models over a cloud-fog network using a Mixed Integer Linear Programming (MILP) optimization model. We exploit virtualization in our framework to provide service abstraction of Deep Neural Networks (DNN) layers that can be composed into a set of VMs interconnected by virtual links. We constrain the number of VMs that can be processed at the IoT layer and study the impact on the performance of the cloud fog approach.

preprint2022arXiv

Energy Efficient VM Placement in a Heterogeneous Fog Computing Architecture

Recent years have witnessed a remarkable development in communication and computing systems, mainly driven by the increasing demands of data and processing intensive applications such as virtual reality, M2M, connected vehicles, IoT services, to name a few. Massive amounts of data will be collected by various mobile and fixed terminals that will need to be processed in order to extract knowledge from the data. Traditionally, a centralized approach is taken for processing the collected data using large data centers connected to a core network. However, due to the scale of the Internet-connected things, transporting raw data all the way to the core network is costly in terms of the power consumption, delay, and privacy. This has compelled researchers to propose different decentralized computing paradigms such as fog computing to process collected data at the network edge close to the terminals and users. In this paper, we study, in a Passive Optical Network (PON)-based collaborative-fog computing system, the impact of the heterogeneity of the fog units capacity and energy-efficiency on the overall energy-efficiency of the fog system. We optimized the virtual machine (VM) placement in this fog system with three fog cells and formulated the problem as a mixed integer linear programming (MILP) optimization model with the objective of minimizing the networking and processing power consumption of the fog system. The results indicate that in our proposed architecture, the processing power consumption is the crucial element to achieve energy efficient VMs placement.

preprint2022arXiv

Energy-Efficient VM Placement in PON-based Data Center Architectures with Cascaded AWGRs

Data centers based on Passive Optical Networks (PONs) can offer scalability, low cost and high energy-efficiency. Application in data centers can use Virtual Machines (VMs) to provide efficient utilization of the physical resources. This paper investigates the impact of VM placement on the energyefficiency in a PON-based data center architecture that utilizes cascaded Arrayed Waveguide Grating Routers (AWGRs). In this paper, we develop a Mixed Integer Linear Programming (MILP) optimization model to optimize the VM placement in the proposed PON-based data center architecture. This optimization aims to minimize the power consumption of the networking and computing by placing the VMs and their demands in the optimum number of resources (i.e., servers and networking devices) in the data center. We first minimize the processing power consumption only and then we minimize the processing and networking power consumption. The results show that a reduction in the networking power consumption by up to 75% is achieved when performing joint minimization of processing and networking power consumption compared to considering the minimization of the processing power consumption only.

preprint2022arXiv

OWC-enabled Spine and Leaf Architecture Towards Energy Efficient Data Center Networks

Due to the emergence of new paradigms and services such as 5G/6G, IoT, and more, current deployed wired Data Center Networks (DCNs) are not meeting the required performance metrics due to their limited reconfigurability, scalability, and throughput. To that end, wireless DCNs using technologies such as Optical Wireless Communication (OWC) have become viable and costeffective solutions as they offer higher capacity, better energy efficiency, and better scalability. This paper proposes an OWC-based spine and leaf DCNs where the leaf switches are enabled with OWC transceivers, and the spine switches are replaced by Access Points (APs) in the ceiling connected to a backbone network. The APs are interconnected through a Passive Optical Network (PON) that also connects the architecture with upper network layers. An Infrared (IR) OWC system that employs Wavelength Division Multiplexing (WDM) is proposed to enhance the DCN downlink communication. The simulation (i.e., channel modeling) results show that our proposed data center links achieve good data rates in the data center up to 15 Gbps. For the PON, Arrayed Waveguide Grating Routers (AWGRs) that enable WDM are proposed to connect the APs. We evaluate the performance of the considered architecture in term of its power efficiency compared to traditional spine and leaf data centers. The results show that the OWC-enabled DCN reduces the power consumption by 42% compared to traditional the spine and leaf architecture.

preprint2020arXiv

PON-based connectivity for fog computing

Fog computing plays a crucial role in satisfying the requirements of delay-sensitive applications such as connected vehicles, smart grids, and actuator networks by moving data processing close to end users. Passive optical networks (PONs) are widely used in access networks to reduce the power consumption while providing high bandwidth to end users under flexible designs. Typically, distributed fog computing units in access networks have limited processing and storage capacities that can be under or over utilized depending on instantaneous demands. To extend the available capacity in access network, this paper proposes a fog computing architecture based on SDN-enabled PONs to achieve full connectivity among distributed fog computing servers. The power consumption results show that this architecture can achieve up to about 80% power savings in comparison to legacy fog computing based on spine and leaf data centers with the same number of servers.