Source author record

Saeed Ranjbar

Saeed Ranjbar appears in the imported research catalog. Authorship, coauthor and topic links are available while profile ownership is still unclaimed.

ResearcherUnclaimed source record

Catalog footprint

What is connected

7works
4topics
4close collaborators

Actions

Connect this record

Log in to claim

Research graph

See the researcher in context

Open full explorer

Inspect adjacent papers, topics, institutions and collaborators without losing the researcher page.

Building this map preview

BZPEER is loading the nearby papers, people, topics and institutions for this page.

Published work

7 published item(s)

preprint2015arXiv

A novel mathematical technique to assess of the mitral valve dynamics based on echocardiography

Purpose: The mechanics of the mitral valve leaflet as a nonlinear, inelastic and anisotropic soft tissue results from an integrated response of many mathematical/physical indexes' that illustrate the tissue. In the past decade, finite element modeling of complete heart valves has greatly aided evaluation of heart valve surgery, design of bioprosthetic valve replacements, and general understanding of healthy and abnormal cardiac function. Such a model must be based on an accurate description of the mechanical behavior of the valve material. It is essential to calculate velocity/displacement and strain rate/strain at a component level that is to work at the cellular level. In this study we developed the first three-dimensional displacement vectors field in the characterization of mitral valve leaflets in continuum equations of inelasticity framework based on echocardiography. Method: Much of our knowledge of abnormal mitral valve function is based on surgical and post-mortem studies while these studies are quantitative in some cases, they are limited by evaluation of valve anatomy in a fixed and nonfunctioning state. A more sophisticated analysis method is necessary to gain a full considerate of mitral valve function. Several groups attempted to model mitral valve anatomy and function by mathematical/physical equations. Result: Preliminary results concerning a different aspect of MVL biomechanics, such as leaflets dynamics, displacements/velocities and strain rates/strains of points on leaflets, were in good agreement with in echocardiographic observations.

preprint2015arXiv

A Novel Mathematical/Numerical Formula for Assessing Right Ventricular Torsion Using Echocardiographic Imaging

Recently, the ventricular torsional parameters have received special attention because of their significant role in the ventricular systolic and diastolic function. Right ventricular (RV) rotational deformation is a sensitive index for RV performance but difficult to measure. Having assumed RV as a conic shape, the present study serves a novel mathematical formula of right ventricular rotation that uses velocity vector imaging (VVI) for quantifying RV.

preprint2015arXiv

Inverse Galois Problem and Significant Methods

The inverse problem of Galois Theory was developed in the early 1800 s as an approach to understand polynomials and their roots. The inverse Galois problem states whether any finite group can be realized as a Galois group over Q (field of rational numbers). There has been considerable progress in this as yet unsolved problem. Here, we shall discuss some of the most significant results on this problem. This paper also presents a nice variety of significant methods in connection with the problem such as the Hilbert irreducibility theorem, Noether s problem, and rigidity method and so on.

preprint2015arXiv

Left ventricular myocardium of heart as a 3D scheme

In this paper it will be shown that according to the scheme theory in algebraic geometry, human heart as an elastic body can be represented as a 3D scheme, on account of algebraic equations of the myocardial fibers as the local parts of the global scheme. It is possible that the fiber movements to be discussed here are identical with the so-called "myocardial fiber transactions"; however the information available to me regarding the latter is lacking in precision, that I can from no judgment in the matter. It is hoped that some enquirer may succeed shortly in this introduced scheme suggested here, which is so important in connection with the theory of schemes.

preprint2014arXiv

Artificial Left Ventricle

This Artificial left ventricle is based on a simple conic assumption shape for left ventricle where its motion is made by attached compressed elastic tubes to its walls which are regarded to electrical points at each nodal .This compressed tubes are playing the role of myofibers in the myocardium of the left ventricle. These elastic tubes have helical shapes and are transacting on these helical bands dynamically. At this invention we give an algorithm of this artificial left ventricle construction that of course the effect of the blood flow in LV is observed with making beneficiary used of sensors to obtain this effecting, something like to lifegates problem. The main problem is to evaluate powers that are interacted between elastic body (left ventricle) and fluid (blood). The main goal of this invention is to show that artificial heart is not just a pump, but mechanical modeling of LV wall and its interaction with blood in it (blood movement modeling) can introduce an artificial heart closed to natural heart.

preprint2014arXiv

Mathematical modeling applied to the left ventricle of heart

Background: How can mathematics help us to understand the mechanism of the cardiac motion? The best known approach is to take a mathematical model of the fibered structure, insert it into a more-or-less complex model of cardiac architecture, and then study the resulting fibers of activation that propagate through the myocardium. In our paper, we have attempted to create a novel software capable of demonstrate left ventricular (LV) model in normal hearts. Method: Echocardiography was performed on 70 healthy volunteers. Data evaluated included: velocity (radial, longitudinal, rotational and vector point), displacement (longitudinal and rotational), strain rate (longitudinal and circumferential) and strain (radial, longitudinal and circumferential) of all 16 LV myocardial segments. Using these data, force vectors of myocardial samples were estimated by MATLAB software, interfaced in the echocardiograph system. Dynamic orientation contraction (through the cardiac cycle) of every individual myocardial fiber could be created by adding together the sequential steps of the multiple fragmented sectors of that fiber. This way we attempted to mechanically illustrate the global LV model. Result: Our study shows that in normal cases myocardial fibers initiate from the posterior basal region of the heart, continues through the LV free wall, reaches the septum, loops around the apex, ascends, and ends at the superior-anterior edge of LV. Conclusion: We were able to define the whole LV myocardial model mathematically, by MATLAB software in normal subjects. This will enable physicians to diagnose and follow up many cardiac diseases when this software is interfaced within echocardiographic machines.

preprint2014arXiv

Ventricular torsional relation to ventricular fiber arrangement

Left ventricular torsion from helically oriented myofibers is a key parameter of cardiac performance. Physicians observing heart motion on echocardiograms, during cardiac catheterization, or in the operating room, are impressed by the twisting or rotary motion of the left ventricle during systole. Conceptually, the heart has been treated as a pressure chamber. The rotary or torsional deformation has been poorly understood by basic scientists and has lacked clinical relevance. The aim of this paper attempts to discuss about this question: Is ventricular twisting related to ventricular fiber arrangement? That is dependent to an assumed model of the left ventricular structure.