Source author record

S Sivaranjani

S Sivaranjani appears in the imported research catalog. Authorship, coauthor and topic links are available while profile ownership is still unclaimed.

ResearcherUnclaimed source record

Catalog footprint

What is connected

2works
2topics
4close collaborators

Actions

Connect this record

Log in to claim

Research graph

See the researcher in context

Open full explorer

Inspect adjacent papers, topics, institutions and collaborators without losing the researcher page.

Building this map preview

BZPEER is loading the nearby papers, people, topics and institutions for this page.

Published work

2 published item(s)

preprint2020arXiv

Distributed Mixed Voltage Angle and Frequency Droop Control of Microgrid Interconnections with Loss of Distribution-PMU Measurements

Recent advances in distribution-level phasor measurement unit (D-PMU) technology have enabled the use of voltage phase angle measurements for direct load sharing control in distribution-level microgrid interconnections with high penetration of renewable distributed energy resources (DERs). In particular, D-PMU enabled voltage angle droop control has the potential to enhance stability and transient performance in such microgrid interconnections. However, these angle droop control designs are vulnerable to D-PMU angle measurement losses that frequently occur due to the unavailability of a GPS signal for synchronization. In the event of such measurement losses, angle droop controlled microgrid interconnections may suffer from poor performance and potentially lose stability. In this paper, we propose a novel distributed mixed voltage angle and frequency droop control (D-MAFD) framework to improve the reliability of angle droop controlled microgrid interconnections. In this framework, when the D-PMU phase angle measurement is lost at a microgrid, conventional frequency droop control is temporarily used for primary control in place of angle droop control to guarantee stability. We model the microgrid interconnection with this primary control architecture as a nonlinear switched system and design distributed secondary controllers to guarantee transient stability of the network. Further, we incorporate performance specifications such as robustness to generation-load mismatch and network topology changes in the distributed control design. We demonstrate the performance of this control framework by simulation on a test 123-feeder distribution network.

preprint2020arXiv

Mixed Voltage Angle and Frequency Droop Control for Transient Stability of Interconnected Microgrids with Loss of PMU Measurements

We consider the problem of guaranteeing transient stability of a network of interconnected angle droop controlled microgrids, where voltage phase angle measurements from phasor measurement units (PMUs) may be lost, leading to poor performance and instability. In this paper, we propose a novel mixed voltage angle and frequency droop control (MAFD) framework to improve the reliability of such angle droop controlled microgrid interconnections. In this framework, when the phase angle measurement is lost at a microgrid, conventional frequency droop control is temporarily used for primary control in place of angle droop control. We model the network of interconnected microgrids with the MAFD architecture as a nonlinear switched system. We then propose a dissipativity-based distributed secondary control design to guarantee transient stability of this network under arbitrary switching between angle droop and frequency droop controllers. We demonstrate the performance of this control framework by simulation on a test 123-feeder distribution network.