Source author record

S. S. Kernasovskiy

S. S. Kernasovskiy appears in the imported research catalog. Authorship, coauthor and topic links are available while profile ownership is still unclaimed.

ResearcherUnclaimed source record

Catalog footprint

What is connected

2works
2topics
4close collaborators

Actions

Connect this record

Log in to claim

Research graph

See the researcher in context

Open full explorer

Inspect adjacent papers, topics, institutions and collaborators without losing the researcher page.

Building this map preview

BZPEER is loading the nearby papers, people, topics and institutions for this page.

Published work

2 published item(s)

preprint2015arXiv

Degree-Scale CMB Polarization Measurements from Three Years of BICEP1 Data

BICEP1 is a millimeter-wavelength telescope designed specifically to measure the inflationary B-mode polarization of the Cosmic Microwave Background (CMB) at degree angular scales. We present results from an analysis of the data acquired during three seasons of observations at the South Pole (2006 to 2008). This work extends the two-year result published in Chiang et al. (2010), with additional data from the third season and relaxed detector-selection criteria. This analysis also introduces a more comprehensive estimation of band-power window functions, improved likelihood estimation methods and a new technique for deprojecting monopole temperature-to-polarization leakage which reduces this class of systematic uncertainty to a negligible level. We present maps of temperature, E- and B-mode polarization, and their associated angular power spectra. The improvement in the map noise level and polarization spectra error bars are consistent with the 52% increase in integration time relative to Chiang et al. (2010). We confirm both self-consistency of the polarization data and consistency with the two-year results. We measure the angular power spectra at 21 <= l <= 335 and find that the EE spectrum is consistent with Lambda Cold Dark Matter (LCDM) cosmology, with the first acoustic peak of the EE spectrum now detected at 15sigma. The BB spectrum remains consistent with zero. From B-modes only, we constrain the tensor-to-scalar ratio to r = 0.03+0.27-0.23, or r < 0.70 at 95% confidence level.

preprint2013arXiv

Self-Calibration of BICEP1 Three-Year Data and Constraints on Astrophysical Polarization Rotation

Cosmic Microwave Background (CMB) polarimeters aspire to measure the faint $B$-mode signature predicted to arise from inflationary gravitational waves. They also have the potential to constrain cosmic birefringence which would produce non-zero expectation values for the CMB's $TB$ and $EB$ spectra. However, instrumental systematic effects can also cause these $TB$ and $EB$ correlations to be non-zero. In particular, an overall miscalibration of the polarization orientation of the detectors produces $TB$ and $EB$ spectra which are degenerate with isotropic cosmological birefringence, while also introducing a small but predictable bias on the $BB$ spectrum. The \bicep three-year spectra, which use our standard calibration of detector polarization angles from a dielectric sheet, are consistent with a polarization rotation of $α= -2.77^\circ \pm 0.86^\circ \text{(statistical)} \pm 1.3^\circ \text{(systematic)}$. We revise the estimate of systematic error on the polarization rotation angle from the two-year analysis by comparing multiple calibration methods. We investigate the polarization rotation for the \bicep 100 GHz and 150 GHz bands separately to investigate theoretical models that produce frequency-dependent cosmic birefringence. We find no evidence in the data supporting either these models or Faraday rotation of the CMB polarization by the Milky Way galaxy's magnetic field. If we assume that there is no cosmic birefringence, we can use the $TB$ and $EB$ spectra to calibrate detector polarization orientations, thus reducing bias of the cosmological $B$-mode spectrum from leaked $E$-modes due to possible polarization orientation miscalibration. After applying this "self-calibration" process, we find that the upper limit on the tensor-to-scalar ratio decreases slightly, from $r<0.70$ to $r<0.65$ at $95\%$ confidence.