Published work

4 published item(s)

preprint2026arXiv

Proton therapy range uncertainty reduction using vendor-agnostic tissue characterization on a virtual photon-counting CT head scan

In this work, we proposed virtual imaging simulators as an alternative approach to experimental validation of beam range uncertainty in complex patient geometry using a computational model of a human head and a photon-counting CT scanner. We validate the accuracy of stopping power ratio (SPR) calculations using a conventional stoichiometric calibration approach and a prototype software, TissueXplorer. A validated CT simulator (DukeSim) was used to generate photon-counting CT projections of a computational head model, which were reconstructed with an open-source toolbox (ASTRA). The dose of 2 Gy was delivered through protons in a single fraction to target two different cases of nasal and brain tumors with a single lateral beam angle. Ground truth treatment plan was made directly on the computational head model using clinical treatment planning software (RayStation). This plan was then recalculated on the corresponding CT images for which SPR values were estimated using both the conventional method and the prototype software TissueXplorer. The mean percentage difference in estimating the stopping power ratio with TissueXplorer in all head tissues inside the scanned volume was 0.28%. Stopping power ratios obtained with this method showed smaller dose distribution differences from the ground truth plan than the conventional stoichiometric calibration method on the computational head model. Virtual imaging offers an alternative approach to validation of the SPR prediction from CT imaging, as well as its effect on the dose distribution and thus downstream clinical outcomes. According to this simulation study, software solutions that utilize spectral information, such as TissueXplorer, hold promise for more accurate prediction of the stopping power ratio than the conventional stoichiometric approach.

preprint2022arXiv

Dosimetric commissioning and quality assurance of scanned ion beams at the Italian National Center for Oncological Hadrontherapy

Purpose: To describe the dosimetric commissioning and quality assurance (QA) of the actively scanned proton and carbon ion beams at the Italian National Center for Oncological Hadrontherapy. Methods: The laterally integrated depth-dose-distributions (IDDs) were acquired with the PTW Peakfinder, a variable depth water column, equipped with two Bragg peak ionization chambers. FLUKA MC code was used to generate the energy libraries, the IDDs in water, and the fragment spectra for carbon beams. EBT3 films were used for spot size measurements, beam position over the scan field, and homogeneity in 2D-fields. Beam monitor calibration was performed in terms of number of particles per MU using both a Farmer-type and an Advanced Markus ionization chamber. The beam position at the isocenter, beam monitor calibration curve, dose constancy in the center of the spread-out-Bragg-peak, dose homogeneity in 2D-fields, beam energy, spot size, and spot position over the scan field are all checked on a daily basis for both protons and carbon ions and on all beam lines. Results: The simulated IDDs showed an excellent agreement with the measured experimental curves. The measured FWHM of the pencil beam in air at the isocenter was from 0.7 to 2.2 cm for protons. For carbon ions, two sets of spot size are available: from 0.4 to 0.8 cm (for the smaller) and from 0.8 to 1.1 cm (for the larger one). The spot position was within +/-1 mm over the whole 20x20 cm2 scan field; homogeneity in a uniform squared field was within +/-5% for both particle types at any energy. QA results exceeding tolerance levels were rarely found. In the reporting period, the machine downtime was around 6%, of which 4.5% was due to planned maintenance shutdowns. Conclusions: After successful dosimetric beam commissioning, quality assurance measurements performed during a 24-month period show very stable beam characteristics.

preprint2016arXiv

Roton excitations and the fluid-solid phase transition in superfluid 2D Yukawa Bosons

We compute several ground state properties and the dynamical structure factor of a 0-temperature system of Bosons interacting with the 2D screened Coulomb (2D-SC) potential. We resort to the exact shadow path integral ground state (SPIGS) quantum Monte Carlo method to compute the imaginary-time correlation function of the model, and to the genetic algorithm via falsification of theories (GIFT) to retrieve the dynamical structure factor. We provide a detailed comparison of ground state properties and collective excitations of 2D-SC and 4He atoms. The roton energy of the 2D-SC system is an increasing function of density, and not a decreasing one as in 4He. This result is in contrast with the view that the roton is the soft mode of the fluid-solid transition. We uncover a remarkable quasi-universality of backflow and of other properties when expressed in terms of the amount of short range order as quantified by the height of the first peak of the static structure factor.

preprint2014arXiv

First tests for an online treatment monitoring system with in-beam PET for proton therapy

PET imaging is a non-invasive technique for particle range verification in proton therapy. It is based on measuring the beta+ annihilations caused by nuclear interactions of the protons in the patient. In this work we present measurements for proton range verification in phantoms, performed at the CNAO particle therapy treatment center in Pavia, Italy, with our 10 x 10 cm^2 planar PET prototype DoPET. PMMA phantoms were irradiated with mono-energetic proton beams and clinical treatment plans, and PET data were acquired during and shortly after proton irradiation. We created 1-D profiles of the beta+ activity along the proton beam-axis, and evaluated the difference between the proximal rise and the distal fall-off position of the activity distribution. A good agreement with FLUKA Monte Carlo predictions was obtained. We also assessed the system response when the PMMA phantom contained an air cavity. The system was able to detect these cavities quickly after irradiation.