Source author record

S. M. Brewer

Explore this author’s publications, collaborators and research topics. This catalog record has not been claimed by its author.

ResearcherUnclaimed source record

Catalog footprint

Research overview

2works
1topics
4close collaborators

Published work

2 publications

preprint2022arXiv

Radium Ion Optical Clock

We report the first operation of a Ra+^{+} optical clock, a promising high-performance clock candidate. The clock uses a single trapped 226^{226}Ra+^{+} ion and operates on the 7s 2S1/2→7s\ ^2S_{1/2}\rightarrow 6d 2D5/26d\ ^2D_{5/2} electric quadrupole transition. By self-referencing three pairs of symmetric Zeeman transitions, we demonstrate a frequency instability of 1.1×10−13\times10^{-13}/τ\sqrtτ, where ττ is the averaging time in seconds. The total systematic uncertainty is evaluated to be Δν/ν=9×10−16{Δν/ ν= 9 \times 10^{-16}}. Using the clock, we realize the first measurement of the ratio of the D5/2D_{5/2} state to the S1/2S_{1/2} state Landé gg-factors: gD/gSg_{D}/g_{S} = 0.5988053(11). A Ra+^{+} optical clock could improve limits on the time variation of the fine structure constant, α˙/α\dot α/ α, in an optical frequency comparison. The ion also has several features that make it a suitable system for a transportable optical clock.

preprint2020arXiv

Lifetime-Limited Interrogation of Two Independent 27Al+{}^{27}\textrm{Al}^{+} Clocks Using Correlation Spectroscopy

Laser decoherence limits the stability of optical clocks by broadening the observable resonance linewidths and adding noise during the dead time between clock probes. Correlation spectroscopy avoids these limitations by measuring correlated atomic transitions between two ensembles, which provides a frequency difference measurement independent of laser noise. Here, we apply this technique to perform stability measurements between two independent clocks based on the 1S0↔3P0^1S_0\leftrightarrow{}^3P_0 transition in 27^{27}Al+^+. By stabilizing the dominant sources of differential phase noise between the two clocks, we observe coherence between them during synchronous Ramsey interrogations as long as 8 s at a frequency of 1.12×10151.12\times10^{15} Hz. The observed contrast in the correlation spectroscopy signal is consistent with the 20.6 s 3P0^3P_0 state lifetime and supports a measurement instability of (1.8±0.5)×10−16/τ/s(1.8\pm0.5)\times 10^{-16}/\sqrt{τ/\textrm{s}} for averaging periods longer than the probe duration when deadtime is negligible.

Research graph

See the researcher in context

Open full explorer

Inspect adjacent papers, topics, institutions and collaborators without losing the researcher page.

Building this map preview

BZPEER is loading the nearby papers, people, topics and institutions for this page.